Furman P-1800 AR Prestige Serie Скачать руководство пользователя страница 4

4

P-1800 AR OWNER’S MANUAL

FURMAN P-1800 AR FEATURES

True RMS Voltage Regulation 

• 

-

 

A 15 amp ultra-low noise toroidal autoformer with microprocessor control

SMP 

• 

(Series Multi-Stage Protection) with EVS (Extreme Voltage Shutdown)

LiFT

• 

 (Linear Filtering Technology) with zero ground contamination

Nine total regulated, filtered and protected AC outlets (three with “wall wart” spacing and Furman Secure Straps to hold bulky 

• 

transformers in place)
Very low stray magnetic field leakage

• 

Dimmable/Switchable true RMS digital ammeter and laboratory precise voltmeter

• 

Tri-color voltage range indicator (complements numerical voltage reading - even when viewed at a distance from the display)

• 

Front panel USB connector charges most portable media devices and cell phones

• 

BNC connector on the rear panel allows you to attach any standard (12VAC 0.5 amp) gooseneck lamp to illuminate the rear of 

• 

your rack (Furman GN-I and GN-LED accessory gooseneck lamps (sold separately) are recommended for this application) 
15 amp (1800 watt) current capacity; output capacity 12 to 15 amps

• 

Robust 14awg. 10 foot AC cord 

• 

Five year limited warranty

• 

INTRODUCTION

 

Thank you for purchasing a Furman Prestige Series Voltage Regulator/Power Conditioner, and congratulations on your choice.  The 
Prestige Series P-1800 AR features Furman’s True RMS Auto Regulation, Series Multi-Stage Protection (SMP) circuit, and our exclusive 
Linear Filtering Technology (LiFT).  Together, these technologies comprise precisely what our customers have grown to expect from 
Furman: uncompromised protection and purification.  The P-1800 AR has been precisely engineered to more than meet the critical 
demands of recording studios, broadcast facilities, and discerning musicians alike.   

The Furman P-1800 AR is intended to protect sensitive electronic equipment from problems caused by AC line voltage irregularities—
brownouts or over-voltages that can cause audio tonal changes, digital equipment malfunction (such as loss of MIDI programs or other 
data), or, in extreme cases, permanent damage. It accepts input voltages over a wide AC voltage range and converts them to a steady, 
stable output of 120V, plus or minus five volts. Voltages approximately ±10% beyond that range may be converted to usable levels, 
depending on the requirements of the equipment. This stable voltage protects equipment and allows optimal performance. If you 
frequently move your rack to different locations, derive power from generators, use excessively long extension cords, travel interna-
tionally, or are in an area prone to brownouts, you will benefit from the use of a Furman P-1800 AR.  

DESCRIPTION

True RMS Voltage Regulation Technology
True RMS Voltage Regulation is designed around an ultra-low noise eight-tap toroidal autoformer.  A microprocessor within the P-1800 
AR monitors the incoming RMS voltage with each cycle, measuring the phase angle in time with the advancing cycle.  Most commer-
cial voltage regulators using multiple-tapped transformers switch taps at uncontrolled times. This creates voltage spikes and clicks that 
can leak into audio. When a voltage fluctuation requires correction by the P-1800 AR, True RMS Voltage Regulation advances a new tap 
with less stress and in turn avoids distortion to the AC waveform. Hysteresis in the P-1800 AR circuits avoids the unnecessary switching 
back and forth between the adjacent taps (or “chatter”) found in many commercial voltage regulators. If necessary, True RMS Voltage 
Regulation technology can switch taps as often as once each cycle and do so with a shorter recovery time than a commercial voltage 
regulator. In addition and unlike voltage regulators that employ ferroresonant transformers, the P-1800 AR is not sensitive to small er-
rors in line frequency, making it ideal for use with generators.
The P-1800 AR has eight outlets on the rear panel and one convenience outlet on the front panel. All are functionally interchangeable. 
The outlets are regulated, surge-suppressed, and linearly filtered, making the unit a full-function power conditioner. The autoformer’s 
toroidal design assures minimal leakage of stray magnetic fields.  

Note:

 

P-1800 AR is for use with AC voltage only. DC voltages should never be applied. Also, it does not change or regulate line  

Frequency. The output frequency will always be the same as the incoming frequency. 

SMP (Series Multi-Stage Protection) with EVS (Extreme Voltage Shutdown)
Furman’s SMP (Series Multi-Stage Protection) surge suppression virtually eliminates service calls and costly “down time”.  Traditional 
surge suppression circuits sacrifice themselves when exposed to multiple transient voltage spikes, requiring the dismantling of your 
system, and repair of your surge suppressor.  Not so with Furman’s SMP.  With SMP, damaging transient voltages are safely absorbed, 
clamped, and dissipated.  Your connected equipment is protected, while your P-1800 AR protects itself!   

Содержание P-1800 AR Prestige Serie

Страница 1: ......

Страница 2: ......

Страница 3: ...ALL CONTENT 2009 FURMAN ALL RIGHTS RESERVED PRINTED IN CHINA ENGLISH Page 4 FRAN AIS Page 12 ESPA OL Page 20 P 1800 AR OWNER S MANUAL P 1800 AR GUIDE DE L UTILISATEUR P 1800 AR MANUAL DEL PROPIETARIO...

Страница 4: ...optimal performance If you frequently move your rack to different locations derive power from generators use excessively long extension cords travel interna tionally or are in an area prone to brownou...

Страница 5: ...measures current draw for an instant analysis of system requirements The P 1800 AR is equipped with nine regulated outlets a front panel convenience AC outlet and eight rear panel outlets Three of th...

Страница 6: ...load conditions capacitive inductive or resistive To switch between voltage and current press the button labeled Line Voltage Current To change the display intensity hold this but ton down for two se...

Страница 7: ...ithout some degree of damage such as a direct lightning hit in an outdoor application In the rare instance that this occurs the green Protection OK LED indicator located to the lower right of the volt...

Страница 8: ...to be covered by this warranty Furman shall authorize purchaser to return the product to Furman headquarters Warranty claims MUST be accompanied by a copy of the original purchase invoice or receipt s...

Страница 9: ...nanosecond MAXIMUM SURGE CURRENT 6 500 AMPS NOISE ATTENUATION 10 dB 10kHz 40 dB 100kHz 50 dB 500kHz DIMENSIONS 19 W x 12 0 D x 1 745 H WEIGHT 15 lbs 7 kg POWER CONSUMPTION No load 5 Watts P 1800 PF R...

Страница 10: ...10 P 1800 AR OWNER S MANUAL AR VOLTAGE RANGE AR OUTPUT CURRENT RANGE...

Страница 11: ...11 FRAN AIS ENGLISH Espa ol NOTES...

Страница 12: ...les surtensions qui peuvent provoquer des modifications de la tonalit des sons une d faillance des appareils num riques tel que la perte de logiciels MIDI ou d autres donn es ou dans des cas extr mes...

Страница 13: ...es ou modes conventionnels Les tech nologies pr c dentes pouvaient en effet nuire aux performances du son et de l image plus qu elles ne les aidaient cause du pic r sonnant de leur conception v tuste...

Страница 14: ...r a t endommag 8 Une mise la terre de s curit est n cessaire pour le bon fonctionnement du P 1800 AR Toute tentative d utilisation de l appareil sans mise la terre de s curit est consid r e comme un f...

Страница 15: ...e totale de sorte telle qu elle n exc de pas les 12 A ou 1400 watts Veuillez noter que cela fait r f rence aux besoins cumul s d alimentation de tous les quipements branch s sur le P 1800 AR et non pa...

Страница 16: ...n cessite une maintenance en usine voir la section Service la client le ci dessous 2 Sympt me L indicateur de tension extr me est allum Cause possible La tension entrante d passe les 140V provoquant l...

Страница 17: ...tenu responsable que ce soit sur la base de cette garantie limit e ou autre de dommages directs indirects ou sp ciaux Cette garantie limit e exprime toute l tendue des obligations de Furman quant au...

Страница 18: ...LISATEUR GAMME DE TENSION DE L AR COURANT DE SORTIE DE L AR TENSION DE RENDEMENT TENSION D ENTR E Gamme fonctionnelle Gamme r glementaire Arr t de basse tension Arr t haute tension COURANT DE SORTIE D...

Страница 19: ...19 FRAN AIS ENGLISH Espa ol NOTES...

Страница 20: ...o funcio namiento incorrecto de equipo digital como p rdida de programas MIDI u otra informaci n o en casos extremos da o permanente Acepta una amplia gama de voltajes de CA de entrada y los convierte...

Страница 21: ...de ruido a la l nea de CA entrante Y lo que es peor aun la p rdida de informaci n digital la necesidad de reiniciar las preconfiguraciones digitales o la destrucci n de transforma dores digitales se p...

Страница 22: ...do 8 El P 1800 AR requiere la presencia de una superficie de apoyo segura para poder funcionar adecuadamente Cualquier intento de poner la unidad en funcionamiento fuera de una superficie segura se co...

Страница 23: ...para que no exceda los 12 amperes o los 1400 voltios Tenga en cuanta que esto se refiere al requisito de potencia agregada de todos los equipos conectados al P 1800 AR no a cada art culo individual I...

Страница 24: ...vicio t cnico a continuaci n 2 S ntoma El indicador de Voltaje extremo est encendido Posible causa El voltaje de entrada est por encima de los 140 voltios lo cual produce que se corte la electricidad...

Страница 25: ...iva o de alguna otra forma Bajo ninguna circunstancia ya sea que est basada en esta Garant a limitada o no Furmal ser responsable por da os casuales especiales o resultantes Esta Garant a Limitada est...

Страница 26: ...GAMA DEL VOLTAJE DE AR CORRIENTE DE SALIDA DE AR CORRIENTE DE SALIDA DISPONIBLE Parada de la baja tensi n VOLTAJE DE ENTRADA Parada de alto voltaje Gama funcional Gama de regla CORRIENTE DE SALIDA DI...

Страница 27: ...27 FRAN AIS ENGLISH Espa ol NOTAS...

Страница 28: ...1690 Corporate Circle Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com P1800PFR_RevA...

Отзывы: