Furman CONTRACTOR MINIPORT CN-15MP Скачать руководство пользователя страница 6

5

This upgrade is based upon scenario number 3 in 
the ASD-120 manual. The new example substitutes 
CN-2400S units at the old miniport locations.

PRIMARY CONTROL AMP RACK

P

S

+12
STAT
START
REM
FORCE ON

FORCE OFF
REM COMM
GND
RLY COMM
F

ASD-120

A

B
C
D
E

CN-2400S

+12
STAT
REM
GND

STAT

REM

GND

(LOCATION ORIGINALLY WAS A MP-20Q)

STAGE MONITOR CIRCUITS

WAS MP-20

CN-2400S

P

S

+12
STAT
REM
GND

STAT

REM

GND

#1 B

WAS MP-20

CN-2400S

P

S

+12
STAT
REM
GND

STAT

REM

GND

#2

SmartSequencer

 

DIAGRAM 3

 - 

LARGE LEGACY UPGRADE 

BACK PANEL TERMINALS

BACK PANEL TERMINALS

ON

1     2    3    4     5     6    7    8     9             

DIP SWITCH SET #2

FORCE OFF
FORCE OFF

FORCE OFF
FORCE OFF

ON

1     2    3    4     5     6    7    8     9             

DIP SWITCH SET #1

ON

1     2    3    4     5     6    7    8     9             

DIP SWITCH SET

FORCE OFF
FORCE OFF

RS-1 Maintained

Key Switch

+12

STAT

REM

GND

CLASS 2 WIRING

24 AWG RECOMMENDED

1M 

1       2       3       4            5

2M  4M  N.O.

N.C. 

12V ON

12V OFF 

GND

ON 

MOM

MNT 

PRI

SEC 

EVS AUTO

MANUAL 

6          7         8             9              

1      2     3     4     5      6     7     8     9             

ON

FOR REFERENCE 

ONLY

ABBREVIATED 

DESCRIPTIONS

AS SHOWN ON

THE PRODUCT.

NOT

 FOR

SETTING(S)

INSTRUCTIONS.

#1 A

 EXAMPLE 3 DIAGRAM - LARGE LEGACY UPGRADE

 EXAMPLE 4 DIAGRAM - LARGE SET-UP PRIMARY CONTROLLED VIA RS-232

P
P
S
S

CN-1800S

+12
STAT
REM
GND

UNIT 3  

                        

SECONDARY INTERFACE 

NO

NC

C

FORCE OFF
FORCE OFF

P
P
S
S

CN-1800S

+12
STAT
REM
GND

UNIT 2

                          SECONDARY INTERFACE 

NO

NC

C

FORCE OFF
FORCE OFF

FORCE OFF
FORCE OFF

NO

NC

C

ON

1     2    3    4     5     6    7    8     9             

SECONDARY DIP SWITCH SET

SYSTEM CONTROLLER

RS-232 PROTOCOL

CN-1800S

+12
STAT
REM
GND

System controllers can interface 
with the CN Series sequencers 
locally or from the cloud. Yet also 
be interrupted by fire alarms.

SmartSequencer

 

DIAGRAM 4

 - 

LARGE SMART SET-UP PRIMARY INDEPENDENT MULTI-ROOM 

COMMON SETTING FOR  UNITS (2, 3, 4, 5) 

SECONDARY INTERFACE UNITS ABOVE 

UNIT 1 

 

 

 

 PRIMARY INTERFACE 

SEPARATE ROOM

P
P
S
S

FIRE ALARM
3 POLE

ON

1     2    3    4     5     6    7    8     9             

PRIMARY DIP SWITCH SET

COMMON SETTING FOR UNIT 1

PRIMARY INTERFACE UNIT ABOVE

CLASS 2 WIRING

24 AWG RECOMMENDED

V    S    R    G    D

P          S

FORCE OFF

CN-15MP

V    S    R    G    D

P          S

FORCE OFF

UNIT 5

  

                       

UNIT 4

                        

 

 

              

CN-15MP

SECONDARY
INTERFACE

SECONDARY
INTERFACE

FOR REFERENCE ONLY
ABBREVIATED 
DESCRIPTIONS
AS SHOWN ON
THE PRODUCT.

NOT

 FOR

SETTING(S)
INSTRUCTIONS.

GND

ON

MOM

MNT

 

PRI

SEC 

EVS ON

EVS OFF

 

6

7

8

9

1M

 

2M

 

4M

N.O.

N.C.

 

12V ON

12V OFF

1 2

3

4

5

1      2     3     4     5      6     7     8     9             

ON

Содержание CONTRACTOR MINIPORT CN-15MP

Страница 1: ...P A S S C U S CN 20MP CN 15MP Contractor Grade Power Management with SmartSequencing Technology Features SmartSequencing technology allows large complex A V systems to be safely power cycled on and o...

Страница 2: ...g power to the amplifiers When shutting down the A V system a sequencer will turn off the system in the reverse order hence the amps will be turned off first and then the signal processing equipment w...

Страница 3: ...urrent loop In situations where power sequencing is critical or more than one AC electrical circuit is utilized wiring Furman SmartSequencing products in series is simple fast and reliable EVS EXTREME...

Страница 4: ...the manufacturer 10 Refer all servicing to qualified personnel Servicing is required when the unit has been damaged in any way or fails to operate 11 WARNING Do not use power cord as the main power d...

Страница 5: ...ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 ON FOR REFERENCE ONLY ABBREVIATED DESCRIPTIONS AS SHOWN ON THE PRODUCT NOT FOR SETTING S INSTRUCTIONS EXAMPLE 1 DIAGRAM SMA...

Страница 6: ...A EXAMPLE 3 DIAGRAM LARGE LEGACY UPGRADE EXAMPLE 4 DIAGRAM LARGE SET UP PRIMARY CONTROLLED VIA RS 232 P P S S CN 1800S 12 STAT REM GND UNIT 3 SECONDARY INTERFACE NO NC C FORCE OFF FORCE OFF P P S S CN...

Страница 7: ...o the Secondary IN of the next downstream sequencer A Furman SmartSequencing chain communicates using a bucket brigade technique A Primary Unit communicates to the first Secondary Unit downstream by s...

Страница 8: ...control system is either inaccessible or commanding the outputs to an OFF state It should be noted that the FORCE OFF and EVS conditions have priority over the BYPASS switch and if either of these co...

Страница 9: ...will be triggered when the short between the two FORCE OFF pins is removed If a FORCE OFF is triggered the FORCE OFF message will be propagated to all SmartLink connected devices The power to all of t...

Страница 10: ...ate as a Secondary Sequencer 8 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 9 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI...

Страница 11: ...utlet If power is provided to the outlet the LED will illuminate green If the Miniport is operating under safe power conditions and no utility fault conditions exist the POWER LED will remain steadily...

Страница 12: ...ect the signal processing equipment to the Mini ports near the beginning of the chain and the Amplifiers to the sequenc ers nearest the end of the chain This will ensure that the power to the signal p...

Страница 13: ...lative Humidity User Interface Thermal Circuit Breaker Bottom panel pushbutton CN 15MP only Front panel diagnostic indicators Primary link Secondary link Power Extreme Voltage Side Panel DIP Switches...

Отзывы: