Table of Contents

Feature Descriptions_____________________________________ 2
Important Safety Instructions________________________________ 3
Abbreviated Product Features_______________________________3
Set Up Diagrams____________________________________4 & 5
SmartSequencing™101__________________________________ 6
Side Panel Overview _______________________________7, 8 & 9
Front Panel Overview_______________________________10 & 11
Setup and Troubleshooting________________________________ 11
Single Unit Set Up_____________________________________ 11
Multiple Unit Set Up______________________________________11
Breaker  Overload______________________________________11
Re-syncing Multiple Sequencers____________________________12 
Specifications  ________________________________________12
15 Year Limited Warranty_________________________________12

SmartSequencing™

Furman SmartSequencing™ is a contractor-friendly technology that 
makes AC power sequencing easy to employ by non-technical person-
nel.  Using SmartSequencing technology, multiple Furman Contactor 
Series units can be linked together over distances up to 1000 feet using 
inexpensive two conductor wire.  These same two wires not only control 
the sequencers, but also form the backbone of an amazingly robust 
and reliable communication system through which information about 
status, voltage, current, and power can be queried from any device in the 
SmartSequencing network.

Generally, high-priced automation systems are used for large, innovative 
installs, yet these control systems seldom combine AC power distribution 
and bidirectional sequencing.  SmartSequencing™ provides the answer 
right out of the box by offering a simple approach to AC power manage-
ment and control. Furman’s newest power sequencing technology is 
an end-to-end solution that is operational up to 1000 feet via a non-
polarized, isolated current loop.  In situations where power sequencing is 
critical, or more than one AC electrical circuit is utilized, wiring Furman 
SmartSequencing™ products in series is simple, fast and reliable.

EVS (EXTREME VOLTAGE SHUTDOWN)

Furman’s trusted (EVS) over-voltage detection protects against prolonged 
over-voltage conditions, such as accidental connections to 208 or 240 
VAC or an intermittent loss of neutral. It does so by continuously monitor-
ing the incoming AC voltage and when an unsafe condition is detected, 
a relay shuts off the power to the outlets until the overvoltage condition 
has subsided.  The Miniport also allows the EVS shut-down feature to be 
overridden.  The Extreme Voltage Shutdown technology is a tremendous 
asset.

BB-RS232

Remote Access (and BlueBOLT

®

)

The Miniport is a member of Furman’s Contractor series of devices.  All 
members of the Contractor series can be controlled remotely using an 
integral data-link and command API. The remote access feature delivers 
integration with various control systems. The API provides a rich set of 
commands and queries that allow remote control and situational aware-
ness over large distances.  Furman’s optional BlueBOLT

®

 RS-232-to-

Ethernet adaptor provides additional control programming and monitoring 
from any Web-enabled device via Telnet, direct HTTP connection, or www.
mybluebolt.com

Security and Safety

The Miniport is readily adaptable to a wide range of installation requests 
and requirements.  It was designed from the ground up to be out-of-
box compatible with Furman legacy and third party equipment. Forced 
Off inputs and selectable DIP switch settings are provided to allow easy 
interface to devices, such as alarm systems. 

Additional Features

The Miniport is equipped with LED indicators to provide visual aid in 
tracking conditions such as power, protection, sequencing and communi-
cation.  The Miniport CN-15MP is supplied by a 14 AWG, 10 foot AC cord. 
And the Miniport CN-20MP is supplied with a 12 AWG, 10 foot AC cord.

All Contractor Series units are backed by our exclusive 15 year Limited 
Warranty

Содержание CONTRACTOR MINIPORT CN-15MP

Страница 1: ...P A S S C U S CN 20MP CN 15MP Contractor Grade Power Management with SmartSequencing Technology Features SmartSequencing technology allows large complex A V systems to be safely power cycled on and o...

Страница 2: ...g power to the amplifiers When shutting down the A V system a sequencer will turn off the system in the reverse order hence the amps will be turned off first and then the signal processing equipment w...

Страница 3: ...urrent loop In situations where power sequencing is critical or more than one AC electrical circuit is utilized wiring Furman SmartSequencing products in series is simple fast and reliable EVS EXTREME...

Страница 4: ...the manufacturer 10 Refer all servicing to qualified personnel Servicing is required when the unit has been damaged in any way or fails to operate 11 WARNING Do not use power cord as the main power d...

Страница 5: ...ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 ON FOR REFERENCE ONLY ABBREVIATED DESCRIPTIONS AS SHOWN ON THE PRODUCT NOT FOR SETTING S INSTRUCTIONS EXAMPLE 1 DIAGRAM SMA...

Страница 6: ...A EXAMPLE 3 DIAGRAM LARGE LEGACY UPGRADE EXAMPLE 4 DIAGRAM LARGE SET UP PRIMARY CONTROLLED VIA RS 232 P P S S CN 1800S 12 STAT REM GND UNIT 3 SECONDARY INTERFACE NO NC C FORCE OFF FORCE OFF P P S S CN...

Страница 7: ...o the Secondary IN of the next downstream sequencer A Furman SmartSequencing chain communicates using a bucket brigade technique A Primary Unit communicates to the first Secondary Unit downstream by s...

Страница 8: ...control system is either inaccessible or commanding the outputs to an OFF state It should be noted that the FORCE OFF and EVS conditions have priority over the BYPASS switch and if either of these co...

Страница 9: ...will be triggered when the short between the two FORCE OFF pins is removed If a FORCE OFF is triggered the FORCE OFF message will be propagated to all SmartLink connected devices The power to all of t...

Страница 10: ...ate as a Secondary Sequencer 8 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 9 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI...

Страница 11: ...utlet If power is provided to the outlet the LED will illuminate green If the Miniport is operating under safe power conditions and no utility fault conditions exist the POWER LED will remain steadily...

Страница 12: ...ect the signal processing equipment to the Mini ports near the beginning of the chain and the Amplifiers to the sequenc ers nearest the end of the chain This will ensure that the power to the signal p...

Страница 13: ...lative Humidity User Interface Thermal Circuit Breaker Bottom panel pushbutton CN 15MP only Front panel diagnostic indicators Primary link Secondary link Power Extreme Voltage Side Panel DIP Switches...

Отзывы: