9
DIP Switch position 7
is used to define the switching preference for
switches or devices connected to the remote (REM) signal input. The
Miniport can be set to operate in a Maintained Mode (DIP 7 OFF or
DOWN) or a Momentary Mode (DIP 7 ON or UP) dependent upon the
preferred method of remote switching. The factory default for DIP 7 is
OFF (Maintained Mode)
When operating in Maintained Mode, the REM input assumes that an
external switch or device will behave like a toggle switch wherein the
switch contacts remain in a given position (open or closed) until the state
of the switch has been changed. Maintained switching is considered
more stable because control signals must be continuously asserted to
“maintain” a system in operation.
When operating in Momentary Mode, the REM Input assumes that an
external switch will behave like a momentary contact (push button)
switch where the switch contacts are shorted only as long as the button
is pressed. The output will toggle ON or OFF each time the REM input is
activated. Momentary Mode is considered more flexible than Maintained
mode as multiple push button switches, such as the Furman RS-2 can be
wired in parallel and used to toggle a Miniport ON or OFF from multiple
locations.
1,
2,
3
1M
1 2 3
4 5
2M 4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3
4 5 6 7 8 9
4
1M
1 2 3
4
5
2M 4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3
4
5 6 7 8 9
5,
6
1M
1 2 3
4
5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6
7 8 9
1 2 3
4
5 6
7 8 9
7
1M
1 2 3
4 5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6
7
8 9
1 2 3
4 5 6
7
8 9
8
1M
1 2 3
4 5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7
8
9
1 2 3 4 5 6 7
8
9
9
1M
1 2 3
4 5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8
9
1 2 3
4 5 6
7 8
9
DIP 8 Primary / Secondary setting
DIP Switch position 8 is used to define the Miniports role in the SmartSe-
quencing™ system. In an array of sequencers connected via Smart-
Link, there can be only one Primary Sequencer, and multiple (up to 99)
Secondary Sequencers. A Primary Sequencer sends commands to all
Secondary sequencers over the SmartLink interface. If DIP Switch 8 is
ON, the Miniport is set as Primary Sequencer. If DIP Switch 8 is OFF the
Miniport will operate as a Secondary Sequencer.
1,
2,
3
1M
1 2 3
4 5
2M 4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3
4 5 6 7 8 9
4
1M
1 2 3
4
5
2M 4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3
4
5 6 7 8 9
5,
6
1M
1 2 3
4
5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6
7 8 9
1 2 3
4
5 6
7 8 9
7
1M
1 2 3
4 5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6
7
8 9
1 2 3
4 5 6
7
8 9
8
1M
1 2 3
4 5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7
8
9
1 2 3 4 5 6 7
8
9
9
1M
1 2 3
4 5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8
9
1 2 3
4 5 6
7 8
9
DIP 9 EVS ON or EVS OFF setting
DIP Switch position 9 is used to define how the Miniport will behave in
the presence of Extreme voltage. If DIP 9 is ON (EVS = ON) the Miniport
will automatically turn off power to its outlet if the incoming power ever
goes above or below tolerable conditions. If DIP 9 is OFF (EVS = OFF) the
Miniport will register, but not turn off power to its outlet if the incoming
power ever goes above or below tolerable conditions.
For the Miniport the over-voltage EVS triggers at 145 VAC +/- 5% and the
under-voltage EVS is triggered at 77 VAC +/- 5%.
If DIP 9 is set to ON and an EVS event occurs, the Miniport will not au-
tomatically turn on after the EVS event has subsided unless the BYPASS
switch is on, or the remote port has been configured to enable the outlet.
To reactivate a Miniport operating in a Smartlink, all units must be
sequenced off and then back on. This can be done by sequencing the
Primary unit OFF/ON.
Please note, if there is an underlying wiring fault, such as an intermittent
loss of Neutral, the EVS event may continue to be encountered. If this is
the case, an operator should avoid resetting the unit without first check-
ing the source of the problem and perhaps changing the AC source.
1,
2,
3
1M
1 2 3
4 5
2M 4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3
4 5 6 7 8 9
4
1M
1 2 3
4
5
2M 4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
1 2 3
4
5 6 7 8 9
5,
6
1M
1 2 3
4
5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6
7 8 9
1 2 3
4
5 6
7 8 9
7
1M
1 2 3
4 5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6
7
8 9
1 2 3
4 5 6
7
8 9
8
1M
1 2 3
4 5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7
8
9
1 2 3 4 5 6 7
8
9
9
1M
1 2 3
4 5
2M 4M N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8
9
1 2 3
4 5 6
7 8
9
+12V
STAT
REM
GND
DLY OUT
REMOTE
PORT
Default DIP Switch Settings
Remote Port
Default DIP Switch Settings
Default DIP Switch Settings