Safety Check after Servicing
Examine the area surrounding the repaired location for
damage or deterioration. Observe that screws, parts,
and wires have been returned to their original positions.
Afterwards, do the following tests and confirm the speci-
fied values to verify compliance with safety standards.
1. Clearance Distance
When replacing primary circuit components, confirm
specified clearance distance (d) and (d’) between sol-
dered terminals, and between terminals and surround-
ing metallic parts. (See Fig. 1)
Table 1 : Ratings for selected area
AC Line Voltage
Clearance Distance (d) (d’)
110 to 240 V
≥
3mm(d)
≥
6 mm(d’)
Note: This table is unofficial and for reference only.
Be sure to confirm the precise values.
2. Leakage Current Test
Confirm the specified (or lower) leakage current be-
tween B (earth ground, power cord plug prongs) and
externally exposed accessible parts (RF terminals, an-
tenna terminals, video and audio input and output ter-
minals, microphone jacks, earphone jacks, etc.) is lower
than or equal to the specified value in the table below.
Measuring Method (Power ON) :
Insert load Z between B (earth ground, power cord plug
prongs) and exposed accessible parts. Use an AC
voltmeter to measure across the terminals of load Z.
See Fig. 2 and the following table.
AC Voltmeter
(High Impedance)
Exposed Accessible Part
B
One side of
Power Cord Plug Prongs
Z
Fig. 2
Table 2 : Leakage current ratings for selected areas
AC Line Voltage
Load Z
Leakage Current (i)
One side of power cord plug
prongs (B) to:
110 to 240 V
2k
Ω
RES.
Connected in
parallel
i
≤
0.7mA AC Peak
i
≤
2mA DC
RF or
Antenna terminals
50k
Ω
RES.
Connected in
parallel
i
≤
0.7mA AC Peak
i
≤
2mA DC
A/V Input, Output
Note: This table is unofficial and for reference only. Be sure to confirm the precise values.
Chassis or Secondary Conductor
d
d'
Primary Circuit Terminals
Fig. 1
1-2-2
H85G0SFP
Содержание VIP-5000HC MK12
Страница 25: ...BH85G0F01011 B Function CBA Top View Function CBA Bottom View 1 8 17 1 8 18 ...
Страница 54: ... 44 45 S 17 Slide Holder S Slide Holder T S 18 46 L 3 Fig DM17 48 P 9 47 Slide Fig DM18 2 4 8 H85G0DA ...
Страница 58: ...EXPLODED VIEWS Front Panel A1X VIP 5000LR MK12 3 1 1 H85G0FEX ...
Страница 60: ...Packing Some Ref Numbers are not in sequence X1 Unit X20 X3 X2 X4 S1 S3 S4 S7 S7 S6 S5 S2 S2 3 1 3 H85G0PEX ...
Страница 76: ...VIP 5000HC MK12 VIP 5000LR MK12 H85G0 G5PD Printed in Japan 01 05 16 HO ...