![FUNAI VIP-5000HC MK12 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/funai/vip-5000hc-mk12/vip-5000hc-mk12_service-manual_2346104017.webp)
MECHANICAL TROUBLE INDICATOR
Note:
The following symbols will appear on the indicator panel to indicate mechanical trouble.
Indicator
Mode
AUTO REPEAT
at 0.4Hz interval
When power safety is not functioning properly.
at 0.8Hz interval
When capstan/reel mechanism is not functioning properly.
at 1.6Hz interval
When tape loading mechanism is not functioning properly.
at 3.2Hz interval
When cassette loading mechanism is not functioning properly.
at 6.4Hz interval
When the drum is not functioning properly.
1-7-9