9-15
BA03A0F01011
Power Supply & Jack CBA Top View
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
Power Supply CBA
Jack CBA
Содержание LH8-M26BB
Страница 13: ...4 2 A03A0DC 2 Rear Cabinet 1 Stand Assembly S 3 S 4 S 2 S 2 S 2 S 1 Fig D1...
Страница 35: ...9 4 A03A0SCP2 Power Supply 2 Schematic Diagram...
Страница 38: ...9 7 A03A0SCIRF Function Junction Schematic Diagram...
Страница 42: ...9 11 A03A0SCD4 Digital Main 4 Schematic Diagram...
Страница 67: ...LH8 M26BB LT8 M26BB A03A0EP A1EP 2009 12 18...