2-3-3
DUALPALMA
1-A. Preliminary/Final Checking and
Alignment of Tape Path
Purpose:
To make sure that the tape path is well stabilized.
Symptom of Misalignment:
If the tape path is unstable, the tape will be damaged.
Note:
Do not use an Alignment Tape for this proce-
dure. If the unit is not correctly aligned, the tape may
be damaged.
1. Playback a blank cassette tape and check to see
that the tape runs without creasing at Guide Rollers
[2] and [3], and at points A and B on the lead sur-
face. (Refer to Fig M3 and M4.)
2. If creasing is apparent, align the height of the guide
rollers by turning the top of Guide Rollers [2] and
[3] with a Guide Roller Adj. Screwdriver. (Refer to
Fig. M3 and M5.)
3. Check to see that the tape runs without creasing at
Take-up Guide Post [4] or without snaking between
Guide Roller [3] and AC Head. (Fig. M3 and M5)
4. If creasing or snaking is apparent, adjust the Tilt
Adj. Screw of the AC Head. (Fig. M6)
1-B. X Value Alignment
Purpose:
To align the Horizontal Position of the Audio/Control/
Erase Head.
Symptom of Misalignment:
If the Horizontal Position of the Audio/Control/Erase
Head is not properly aligned, maximum envelope can-
not be obtained at the Neutral position of the Tracking
Control Circuit.
1. Connect the oscilloscope to TP301 (C-PB) and
TP503 (CTL) on the Main CBA. Use TP504 (RF-
SW) as a trigger.
2. Playback the Gray Scale of the Alignment Tape
(FL6NS8) and confirm that the PB FM signal is
present.
3. Set the Tracking Control Circuit to the center posi-
tion by pressing CH UP button then “ PLAY ” button
on the unit. (Refer to note on bottom of page
2-3-4.)
4. Use the X-Value Adj. Screwdriver so that the PB
FM signal at TP301 (C-PB) is maximum. (Fig. M6)
5. Press CH UP button on the unit until the CTL wave-
form has shifted by approx. +2msec. Make sure
that the envelope is simply attenuated (shrinks in
height) during this process so that you will know
the envelope has been at its peak.
Guide Roller [2]
Guide Roller [3]
A
B
Take-up Guide Post [4]
AC Head
Fig. M3
Lead Surface of Cylinder
Tape
Fig. M4
Guide Roller
Tape
Correct
Incorrect
Take-up Guide
Post
Tape
Fig. M5
Azimuth Adj. Screw
X-Value Adj.
Screwdriver
Tilt Adj. Screw
AC Head
Fig. M6
Содержание DPVR-2600
Страница 32: ...1 10 6 1 10 7 1 10 8 H9300SCM2 Main 2 7 Schematic Diagram VCR Section ...
Страница 33: ...Main 3 7 Schematic Diagram VCR Section 1 10 9 1 10 10 1 10 11 H9300SCM3 ...
Страница 34: ...Main 4 7 Schematic Diagram VCR Section 1 10 12 1 10 13 1 10 14 H9300SCM4 ...
Страница 35: ...1 10 15 1 10 16 Main 5 7 Schematic Diagram VCR Section H9300SCM5 ...
Страница 36: ...1 10 17 1 10 18 H9300SCM6 Main 6 7 Schematic Diagram VCR Section ...
Страница 37: ...1 10 19 1 10 20 H9300SCM7 Main 7 7 Schematic Diagram VCR Section ...
Страница 43: ...1 10 31 1 10 32 BH9311F01012 B Function CBA Top View Function CBA Bottom View ...
Страница 46: ...1 10 38 1 10 39 1 10 40 BH9311F01012 A Main CBA Bottom View ...
Страница 47: ...1 10 41 1 10 42 1 10 43 H9300SCD1 DVD Main 1 4 Schematic Diagram DVD Section ...
Страница 48: ...1 10 44 1 10 45 1 10 46 H9300SCD2 DVD Main 2 4 Schematic Diagram DVD Section ...
Страница 49: ...1 10 47 1 10 48 1 10 49 H9300SCD3 DVD Main 3 4 Schematic Diagram DVD Section ...
Страница 50: ...1 10 50 1 10 51 1 10 52 H9300SCD4 DVD Main 4 4 Schematic Diagram DVD Section ...
Страница 72: ...2 4 6 DUALPALDA S 12 19 Cap Belt Fig DM11 Fig DM12 20 C 1 21 ...
Страница 79: ...3 1 3 H9300PEX S1 A14 X20 X6 B Some Ref Numbers are not in sequence X2 X3 X4 X1 Unit S3 X5 S2 S2 Packing ...
Страница 99: ...DPVR 2600 DPVR 2700 DPVR 2605 H9300 06 20ED ...