background image

 

DRAWINGS AND FIGURES 

 

Figure 1 

Содержание GS2-200

Страница 1: ...any solid state speed control device WARNING For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors WARNING Use only a 10 Amp fuse CAUTION Do not operate wit...

Страница 2: ...o c a t i n g t h e a i r c l e a n e r Placing the GS2 200 unit as close as possible to the pollution source reduces the amount of ducting needed reduces back pressure lowers power consumption and im...

Страница 3: ...Filter and then press the FILTER RESET button If the light remains illuminated or turns off and comes back on then contact Fumex for assistance The GS2 200 unit contains a VOC sensor to detect odors...

Страница 4: ...s commonly found in industrial manufacturing processes Part FX4 Blend of FX1 with FX2 for broad spectrum gas treatment SELECTING GAS ODOR ADSORBENT FILTERS Media Selection and Service Life Fumex offer...

Страница 5: ...tions only 10 Amp fuse and check the product If the replacement fuse blows a short circuit may be present and the product should be discarded or returned to an authorized service facility for examinat...

Страница 6: ...returned PREPAID to Fumex LLC 1150 Cobb International Pl Kennesaw GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty notwithstanding any knowledge of Fume...

Страница 7: ...flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSwitchO...

Страница 8: ...ia a flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSw...

Страница 9: ...9 DRAWINGS AND FIGURES Figure 1...

Страница 10: ...10 DRAWINGS AND FIGURES Figure 2 Figure 3 ON OFF Relay Activation Switch...

Отзывы: