Operational Steps
1.
Power On
- Press and hold
Power Button
❶
for 5 seconds to power on Handheld Remote
Control (HRC).
2.
Fault indicators
- When power is on
Fault Indicator
❽❾
will show different colours according
to the fault hierarchy listed under
Fault Reference
⓬
when more than one fault occurs, the fault
with lower hierarchy will not be displayed until higher level fault(s) have been cleared.
3.
Test
- When first powered on, the HRC will starts in
Test Mode
and the
Status Indicator
❿
will
show blue. During
Test Mode
the HRC can be used to pair to a specific eSTOP™ unit (Refer to
Pairing section). If the HRC is paired to an eSTOP™ unit the
Fault Indicator
❽❾
will show Blue
and change to green when Synced to the paired eSTOP™ unit (allow up to 1 minute for the Fault
light to turn green and get synced). Once synced the HRC can be used to control the eSTOP™ unit.
Pressing Buttons
❻
or
❼
allows eSTOP™ lanterns to be tested (A quick flashing sequence of the
3 colours to ensure the lights are working).
4.
Activation
- When ready to operate the eSTOP™, hold down
Activation Button
❷
for 5 seconds
to activate the synced eSTOP™ units into
Operation Mode
, the
Status Indicator
❿
will then show
Green. The eSTOP™ will only operate when
Fault Indicator
is green.
5.
Start-up
- Upon switching from
Test Mode
to
Operation Mode
the eSTOP™ lantern will flash
yellow for 5 seconds, then 4 seconds of steady yellow, then default to red. The Hand Control will
lock for 10 seconds and all buttons will not work during this time. After 10 seconds the eSTOP™
unit is in
Operation Mode.
6.
Control Traffic Signals
- Use Buttons
❺❻
or
❼
to operate the eSTOP™ for traffic control. Use
button
❻❼
to switch one or the other signal to turn green. (Note: in order to turn a signal
green one or both signal must be red first). Use button
❺
to change all signals to red. (Note: the
yellow lantern will activate for 4 seconds during the transition from green to red. There is a
minimum red time of 5s. The LED indicators reflect the eSTOP™ lantern status).
7.
De-activation -
In
Operation Mode
, holding
Activation Button
❷
for 5 seconds returns the
eSTOP™ units to
Test Mode
. During transition from
Operation Mode
to
Test Mode
both eSTOP™
unit lanterns flash yellow for 5 seconds.
8.
Power off
- In all modes, hold
Power Button
❶
for 5 seconds to commence power off. During
Operation Mode
the HRC will not power off if the paired units lost sync (comms fail) to an
eSTOP™ unit.
9. Switch off eSTOP™ power and disconnect battery cable before packing up.
Note: While in “off” mode, pressing “STOP” on the HRC will indicate battery life remaining. In the
event of forced power off is required on the HRC, pressing button “1” and “2” at the same time
Fulton Hogan Signs & Graphics | [email protected] | P: 0800 274 463
Page | 15
OP™ Handheld Remote Controller (HRC)
The e TOP™ HRC can be paired to any e TOP™ lantern units. Once a lantern unit is paired to a HRC it
is store in memory, they will be automatically s nce whe p
owere
d up and ready for opett ion. By
de ault a HRC is paired to 1 lante n unit only. Repairing is not required unless the HRC is pairing to a
different laee rn unit pairing 2 lantern unit to 1 HRC, or lanterns has been mixed up and not knowing
which lante n is paired.
It is recommended to bei n pairing by un-pairing all lante n units from the HRC, this will reduce
confus on abt⁴ which lante n unit if alre dy paired previous y. Follow the ste s be ow to bei n the
process.
Power on the HRC and the Lantern units, these must be in test mode for pairing (status
blue on button
❿
)
Un-pairing eSTOP™ units
Un-pairing is required if the HRC is already paired to an unknown lante n and unable to sync.
To do t is the HRC
must be in test mode
(status light is blue, t e USB port
must be
disconnected
from t e e TOP™ unit. Press and hold Unit “Go” butt n
❻
for 5 seconds
until a beep sounds. T e HRC will flash a red light on the
Status Indicator,
te n
Fault1
indicator
will be blank, this indicates no lantern unit is paired to unit1 on HRC.
Repe t this un-pairing process (using Unit2 “Go” button) to un-paire Unit2 (le t s de of the
HRC) if a sen d lantern is paired t Unit side. Aee r un-pairing,
Fault1 and Fault2 indicator
will be blank, where no LED is on.
Pairing eSTOP™ HRC Unit1 (Left side of the HRC)
1. When in test mode attach the micro USB cable from the
top of the HRC unit to the USB conne tor on the bee of the
eSTOP™ lantern unit, s ow on the image.
2. Press and hold Unit1
GO button
❻
for at le st 4 sen ds until a beep su nds. This s ngle beep
indicates pairing has initiate and he button can be rele se .
Whe the pairing press is complete the HRC will su nd e te r a fast double beep as we l as
a green flashing light on te
Status Indicator
or a long s ngle beep with a re light on the
Status Indicator
.
A fast double bee and ee n light indicates s ccess l pairing.
Fault1 indicator
will go blue
once it’s paired and changed to green when synced (wireless communication between HRC
and t e laee rn is established) t te paired unit.
Содержание ESTOP
Страница 28: ......