background image

w w w . f u l l w a t . c o m

LIR18650-34

 

 

Li-ion cylindrical rechargeable battery

 6.5 Cycle Life

Charge cells per 6.1. 2. Rest 15 minutes. Discharge per 6.2.3. Rest 15 minutes before recharge. The test 
environmental  temperature  is  25ºC±2ºC. A  cycle  is  defined  as  one  charge  and  one  discharge.  Discharge 
capacity shall be measured after 500 cycles. 

Discharge capacity (500th Cycle) ≥ 70% of 1st Cycle Capacity 

 6.6 Storage characteristics

After  charge  as  per  standard  charge  method  6.1.1,  store  the  testing  cells  at  25ºC±2ºC  for  28  days. Then 
discharge as per 6.2.2. Then the same cell is fully charged as per 6.1.1 again and discharged a second time 
and measured as per 6.2.2. 

The recovery discharge capacity (2nd discharge capacity) ≥90% of Initial capacity. 

 6.7 Temperature Characteristics 

Cells shall be charged per standard charge method and discharged per 6.2.3. Cells, full charged, shall be stored 
for 3 hours at the test temperature prior to discharging and then shall be discharged at the test temperature. The 
capacity of a cell at each temperature shall be compared to the capacity achieved at 25ºC and the percentage 
shall be calculated. Each cell shall meet or exceed the requirements of Table 2.

Table 2

-10ºC

0ºC

25ºC

45ºC

≥70%

≥80%

100%

≥95%

  7. SAFETY

 7.1 External short-circuiting. Test at 25ºC

Cell charged per standard charge method, is to be short circuited by connecting the positive (+) and negative 
(-) terminals with a total external resistance of 80±20mohm. Stop the test when the cell voltage falls below 0.1V 
and the cell case temperature has returned to a value within 10ºC of the original testing temperature. 

Criteria:

 No Fire, No Explosion 

 7.2 Overcharge test

Cell charged per standard charge method, is to be overcharged with 3C to 4.2V while tapering the charge 
current. Monitoring change of cell temperature during testing. The charge duration is 7 hours. Stop the test 
when cell temperature decays to room temperature. 

Criteria:

 No Fire, No Explosion 

 873 Overdischarge test

Cell charged per standard charge method, is discharged at constant current of 1C for 90min.

Criteria:

 No Fire, No Explosion

 7.4 Heating test

Cell charged per standard charge method, is to be placed in the hot oven. Store the testing cells connecting 
with thermocouple in constant temperature box, heating the cells and box (speed of ascending temperature is 
5ºC±2ºC per min) together at room temperature simultaneity, monitor the temperature change of the box, keep 
for 30 minutes after the box temperature reaches 130ºC±2ºC, then stop the test.

Criteria:

 No Fire, No Explosion

Содержание LIR18650-34

Страница 1: ...w w w f u l l w a t c o m LIR18650 34 Li ion cylindrical rechargeable battery...

Страница 2: ...LIR18650 34 Li ion cylindrical rechargeable battery 1 Scope This product specification has been prepared to specify the Cylindrical Lithium ion Cell 2 Cell dimensions fig 1 Item Specification D 18 4 0...

Страница 3: ...rrent not for cycle 0 C T 10 C 0 1C 335mA 10 C T 20 C 0 2C 670mA 20 C T 45 C 0 3C 1005mA 3 6 Charge time Standard charge 6 0h Rapid charge 4 0h 3 7 Standard discharge Constant current CC Current 0 2C...

Страница 4: ...ng shall be terminated when the charging current has tapered to 0 02C 6 1 2 Charging shall consist of charging at a 0 3C constant current rate until the cell voltage reaches 4 2V The cell shall then b...

Страница 5: ...equirements of Table 2 Table 2 10 C 0 C 25 C 45 C 70 80 100 95 7 SAFETY 7 1 External short circuiting Test at 25 C Cell charged per standard charge method is to be short circuited by connecting the po...

Страница 6: ...floor by the positive and negative terminal down Wait for 1h Criteria No Fire No Explosion 8 Packaging Loading 100 cells per box 2 boxes per case for a total of 200 cells 9 Others Any matter not incl...

Страница 7: ...e end voltage must be over 2 5V 1 2 2 Discharge temperature range should be 20 C 45 C see spec 3 8 If surface temperature exceeds 55 degrees the discharge must be stopped 1 3 Storage Any storage cell...

Страница 8: ...ture protection Set the temperature protection of pack according to the cell use condition in SPEC Battery pack should have cell voltage balancing function and cell imbalance protection circuit Batter...

Страница 9: ...ay fire smoke explode or cause heat 2 1 8 Don t charge near high temperatures If the battery is charged near the high temperature the battery can not be recharged due to the protection line In this ca...

Страница 10: ...e if the battery has an abnormal smell heat or rust please contact the supplier 2 3 7 Keep away from flammable materials during charging and discharging May cause fire smoke explosion or cause heat 2...

Отзывы: