Extended Panel

Full Gauge Controls extended panel allows controllers to be installed in Evolution and Ri lines (the opening 
must measure 71x29mm for the extended panel to be installed), as the opening does not need to be 
precise for the device to be properly installed. The panel has space to be branded with the company logo 
and contact information, and it has 10A switches (250 V ac) that can be used for switching on internal 
lighting, ventilation or fan systems.

EASYPROG

IN ORDER TO COMMUNICATE WITH EASYPROG, THE EQUIPMENT MUST NOT 
BE LINKED TO SITRAD SOFTWARE.

IMPORTANT

12. OPTIONAL ITEMS - Sold separately

EasyProg 

- version 2 or higher

This is an accessory, whose main function is to store the parameters of the controllers. You can load new 
parameters  from  a  controller  at  any  time,  and  download  them  to  a  production  line  (from  the  same 
controller), for example.
It has three types of connection for loading or clearing parameters:

-

 

Serial RS-485:

 Connect it to the controller using the RS-485 network 

(only controllers that can access RS-485).

- USB:

 If connected to the computer by a USB port, it can use Sitrad's Program Editor.

- Serial TTL:

 The controller can connect directly to

EasyProg 

by a Serial TTL connection.

 11. GLOSSARY

°C:

 Temperature in degrees Celsius. 

°F:

 Temperature in degrees Fahrenheit. 

Defr (defrost)

: Defrosting. 

LOC:

 Locked. 

No:

 No.

OFF:

 Turned Off/ deactivated. 

ON: 

Turned On / activated. 

Refr:

 Refrigeration. 

SET :

 set or configure. 

Image VI

PANEL

CLAMPS

CONTROLLER

CONTROLLER

13. ANNEXES - Reference Diagrams

Image V

Y

X

PANEL

To ensure it is properly and safely 
installed, connect all leads before 
putting the controller in position.

14. WARRANTY

ENVIRONMENTALINFORMATION
Packaging:

The materials used in the packaging of Full Gauge products are 100% recyclable. Try to perform 
disposal through specialized recyclers.

Product:

The  components  used  in  Full  Gauge  controllers  can  be  recycled  and  reused  if  disassembled  by 
specialized companies.

Disposal:

Do not incinerate or dispose the controllers that have reached the end of their service as household 
garbage. Observe the laws in your area regarding disposal of electronic waste. If in doubt, please 
contact Full Gauge Controls

W

ARRANTY

 - FULL

 GAUGE CONTROLS

Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) year   warranty, 

as  of  the  date  of  the  consigned  sale,  as  stated  on  the  invoice.  They  are  guaranteed    against 
manufacturing defects that make them unsuitable or inadequate for their intended use.

EXCEPTIONS TO WARRANTY

The  Warranty  does  not  cover  expenses  incurred  for  freight  and/or  insurance  when  sending  

products  with  signs  of  defect  or  faulty  functioning  to  an  authorized  provider  of  technical  support 
services.  The  following  events  are  not  covered  either:  natural  wear  and  tear  of  parts;  external 
damage caused by falls or inadequate packaging of products

LOSS OF WARRANTY

Products will automatically lose its warranty in the following cases:
-  The  instructions  for  assembly  and  use  found  in  the  technical  description  and  installation  

procedures in Standard IEC60364 are not obeyed;

- The product is submitted to conditions beyond the limits specified in its technical description;
- The product is violated or repaired by any person not a member of the technical team of Full 

Gauge Controls;

- Damage has been caused by a fall, blow and/or impact, infiltration of water, overload and/or 

atmospheric discharge.

USE OF WARRANTY

To make use of the warranty, customers must send the properly packaged product to Full Gauge 

Controls together with the invoice or receipt for the corresponding purchase. As much information as 
possible in relation to the issue detected must be sent to facilitate analysis, testing and execution of 
the service

These  procedures  and  any  maintenance  of  the  product  may  only  be  provided  by  Full  Gauge 

Controls Technical Support services in the company's headquarters at Rua Júlio de Castilhos, 250 - 
CEP 92120-030 - Canoas - Rio Grande do Sul – Brasil

Rev. 03

Copyright 2021  Full Gauge Controls    All rights reserved

ECASE PROTECTIVE COVER

Ecase protective cover

Recommended for the Evolution line, it prevents water from 
entering  the  back  of  the  instrument.  Protects  the  product 
when washed in the installation site.

Note:

 Ecase is compatible with the use of small type Faston 

terminals, usually with silicone protection.

Image IX

VYNIL

CONTROLLER

Image VIII

Image VII

Important Note:

Faston connectors must be 
protected with covers, preferably 
made of silicone.

Содержание TC-970E+ECO Faston

Страница 1: ...SEALTHATPREVENTSANYLIQUIDSENTERINGTHEOPENINGANDTHECONTROLLER Power supply Control Temperature Temperature Resolution Average consumption Digital input Maximum Sizes mm Degree of protection 0 1 C 0 1 F...

Страница 2: ...eaudiblealarm brieflypressthe key 8 5 Manual defrost To start stop defrost regardless of the schedule press the key for 4s until the message dEFr appears Then release it The message On will be display...

Страница 3: ...iod of time the defrost will be runfirstandthenitwillgointofastfreezingmode 8 14 Display output frequency The output frequency applied to the variable compressor can be viewed by pressing the key unti...

Страница 4: ...F55 1 On 999 F55 1 On 999 F54 105 0 999 F54 221 0 105 0 500 999 40 0 0 Off 5 104 0 Off 5 1 150 0 Off 1 150 0 Off 4 30 0 Off 4 30 0 Off 999 300 999 105 0 F54 999 9999 221 0 F54 999 9999 999 999 13 999...

Страница 5: ...or example when the electricityreturnsafterapowercut F28 SmoothDefrostif F20 0 Smooth Defrost mode provides a smoother defrosting saving energy and preventing the room temperature from rising as much...

Страница 6: ...parameterworksinconjunctionwith F59 and F60 F59 VariablecompressortimeonincaseoferrorinsensorS1 roomsensor F60 VariablecompressortimeoffincaseoferrorinsensorS1 roomsensor If the room sensor S1 sensor...

Страница 7: ...rtiallocking wherethecontrolfunctionswillbeblockedbuttheadjustmentofthe setpointsandthealterationoftherecipesremainreleased 2 Enablestotallocking leavingonlyaccesstothefunctionsofthefacilitatedmenuava...

Страница 8: ...ols WARRANTY FULL GAUGE CONTROLS Products manufactured by Full Gauge Controls as of May 2005 have a two 02 year warranty as of the date of the consigned sale as stated on the invoice They are guarante...

Отзывы: