Full Gauge TC-970E+ECO Faston Скачать руководство пользователя страница 1

 3. APPLICATIONS

- Beverage Display;
- Frozen counters.

 1. DESCRIPTION

TC970

e

 

Faston

 and 

TC970

e

 

Easycon

 are electronic controllers for 

+ Efgcfg

+69 Eco

refrigerating  freezers,  beverage  displays,  refrigerated  islands  and  counters.  These  controllers  can 
activate the cooling, defrost, fan and lighting system. In addition to those features, they allow users to 
pre-define up to 4 operating temperatures that are easily changed using a keyboard, in addition to 
specific keys to activate/deactivate the economy mode and turn the lamp on/off.
The controller has 2 temperature sensors for controlling the refrigerated environment and intelligent 
defrost control (start and end of defrost by time or temperature). For better use of energy, ventilation can 
be controlled during the compressor off cycle and use Smooth Defrost, a defrosting technique that 
reduces the final temperature of the electrical resistance and the amount of heat emmited.
Through its digital input it is possible to monitor the opening of the door, activation of economy setpoint, 
temperature control of the door or condenser, defrost or Fast-Freezing. The Fast Freezing feature is an 
alternative used after the process of replacing products in the freezer to speed up the cooling process. 
The 

 line adds control of VCC - Variable Capacity Compressor. The 

 controllers provide 

+69Eco

dddd88d

a series of benefits to the cooling system, such as: reduced energy consumption, less temperature 
fluctuation,  greater  speed  in  reaching  the  desired  temperature.  From  the  configuration  of  its 
parameters,  it  is  possible  to  make  the  controller  compatible  with  the  main  brands  of  variable 
compressors on the market.

 2. SAFETY RECOMMENDATIONS

- Make sure you know the correct way to install the controller;
- Make sure that the power supply is turned off and that it is not going to turn in during the installation of 
the controller;
- Read this manual before installing and using the controller;
- Use appropriate Personal Protective Equipment (PPE);
- Where it will be used in areas subject to splashing water, such as refrigerated counters, install the 
protective film that comes with the controller;
- For protection under more critical conditions, we recommend the Ecase cover, which we offer as an 
option (sold separately);
- The  installation  procedures  must  be  carried  out  by  a  competent  engineer,  with  regard  to  current 
regulations.

 4. TECHNICAL SPECIFICATIONS

 7. WIRING DIAGRAM

5. INDICATIONS AND KEYS

6. INSTALLATION - PANEL E ELECTRICAL CONNECTIONS

71 

 mm

± 0,5

29 

 mm

± 0,5 

Panel (Front View)

Panel 

(Side View)

Size of the Bay for

inserting the device

WARNING

WHERE THE INSTALLATION LOCATION NEEDS TO BE SEALED AGAINST LIQUIDS, THE OPENING IN WHICH THE CONTROLLER 
IS TO BE INSTALLED MUST BE NO MORE THAN 70.5x29mm. THE SIDE CLASPS MUST BE SECURED IN SUCH A WAY AS TO 
CREATE A TIGHT RUBBER SEAL THAT PREVENTS ANY LIQUIDS ENTERING THE OPENING AND THE CONTROLLER.

Power supply 

Control Temperature

Temperature Resolution

Average consumption

Digital input

Maximum Sizes (**) (mm)

Degree of protection

0,1°C / 0,1°F

Configurable Dry Contact type

 

76 x 34 x 84 (WxHxD)

TC-970E + Eco Faston: 

TC-970E + Eco Easycon: 

76 x 34 x 78 (WxHxD)

IP 65 (frontal)

TC-970E + Eco Faston: 115 or 230Vac   10%(*) (50/60Hz) 

±

TC-970E + Eco Easycon: 115 or 230Vac   10%(*) (50/60Hz) 

±

TC-970EL + Eco Faston: 12 or 24Vac/dc   10%(*) 

+

TC-970EL + Eco Easycon: 12 or 24Vac/dc   10%(*) 

+

±

 4VA 

Operating humidity

Operating Temperature

Frequency output

Bay Size (mm)

-50 to 105°C / -58 to 221°F

10 a 90% UR (without condensation)

0 to 50°C / 32 to 122°F

12Vcc (± 25%)

0...300Hz (duty-cycle = 50%)

 X = 71

0,5 (see Image 5) 

±0,5 Y= 29±

Maximum relay current

DEFR:

 8A / 250Vac - defrost output

FAN: 

1/8HP / 250Vac - output of the Fan

AUX:

 1/8HP/1A E-Ballast / 250Vac - auxiliary output

(*) Permissible variation in relation to the rated voltage.
(**) Maximum dimensions without connectors.

Image III - Connection 12 Vac/dc

Image I - Connection 115 Vac

Image II - Connection 230 Vac

Image IV - Connection 24 Vac/dc

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

D1/S3

D1/S3

Frequency Output (VCC)

Frequency Output (VCC)

Frequency Output (VCC)

+

+

+

-

-

-

D1/S3

FAN

FAN

230 Vac

115 Vac

 S1

 S1

 S2

 S2

AUX

AUX

O

R

D

IN

A

R

Y

O

R

D

IN

A

R

Y

C

O

M

U

M

COMP

COMP

COMP

DEFR

DEFR

1

1

2

2

3

4 5 6

7

8

9

10 11 12 13

24 Vac/dc

Power
Supply

FAN

AUX

DEFR

1

2

 S1

 S2

A

A

3

4 5 6

7

8

9

10 11 12 13

D1/S3

Frequency Output (VCC)

+ -

FAN

Power
Supply

12 Vac/dc

 S1

 S2

AUX

C

O

M

U

M

COMP

DEFR

1

2

A

A

The 

S1 sensor 

must be in the environment.

The

 S2 sensor

 must be fixed to the evaporator using a metal clamp.

Controller power supply

Use the pins according to the table below, depending on the device version:

Pins

TC970E Faston / Easycon

TC970E Faston / Easycon

7 and 8
7 and 9

115 Vac
230 Vac

12 Vac/dc
24 Vac/dc

CONNECTION SYSTEM (QUICK COUPLING):

CONNECTION:

- Hold the wire close to its end and insert it into the required opening.
- If necessary, press the button to help make the connection.

DISCONNECTION:

- To disconnect the wire, press the button 
and remove it.

The wire must be stripped 
5mm and tinned.

Rocket pin terminal

NOTE:

-  In  the  push-in  connectors  the  maximum  gauge  that  is  used  is 
1,5mm²;
- The wires must be tinned or use Rocket Pin type terminals;
-  For  connections  1  to  6,  use  Rocket  Pin  type  terminals  with  a 
maximum gauge 0,75mm²;
- For connections from 7 to 13 (Easycon model), use the Rocket Pin 
terminal with a maximum gauge of 1,5mm².

DIGITAL COOLING CONTROLLER

ECOV01-01T

-18762

evolution

 

 

TC-970

       Faston

TC-970

e    

   EasyCon

V

er

.01

V

er

.01

Tc970

 

Tc970

 

Led Indicator for defrosting

Led Indicator for the Unit of Temperature

Economic mode indication led

TC-970

e

 

Up Key

Down Key

Set Key

Menu Access
Key

Led Indicator for the auxiliary outlet

Led Indicator for the 

compressor outlet

Led Indicator for the fan

A

Switch

Off Control

Functions

Function

Lock

Programming

in Series

Degree of
protection

Lamp
on/off

IP 65

FRONT

Economy

mode

Quick 

coupling 

connection

Buzzer

Variable 

compressor

VCC

WIRE INLET

BUTTON

Содержание TC-970E+ECO Faston

Страница 1: ...SEALTHATPREVENTSANYLIQUIDSENTERINGTHEOPENINGANDTHECONTROLLER Power supply Control Temperature Temperature Resolution Average consumption Digital input Maximum Sizes mm Degree of protection 0 1 C 0 1 F...

Страница 2: ...eaudiblealarm brieflypressthe key 8 5 Manual defrost To start stop defrost regardless of the schedule press the key for 4s until the message dEFr appears Then release it The message On will be display...

Страница 3: ...iod of time the defrost will be runfirstandthenitwillgointofastfreezingmode 8 14 Display output frequency The output frequency applied to the variable compressor can be viewed by pressing the key unti...

Страница 4: ...F55 1 On 999 F55 1 On 999 F54 105 0 999 F54 221 0 105 0 500 999 40 0 0 Off 5 104 0 Off 5 1 150 0 Off 1 150 0 Off 4 30 0 Off 4 30 0 Off 999 300 999 105 0 F54 999 9999 221 0 F54 999 9999 999 999 13 999...

Страница 5: ...or example when the electricityreturnsafterapowercut F28 SmoothDefrostif F20 0 Smooth Defrost mode provides a smoother defrosting saving energy and preventing the room temperature from rising as much...

Страница 6: ...parameterworksinconjunctionwith F59 and F60 F59 VariablecompressortimeonincaseoferrorinsensorS1 roomsensor F60 VariablecompressortimeoffincaseoferrorinsensorS1 roomsensor If the room sensor S1 sensor...

Страница 7: ...rtiallocking wherethecontrolfunctionswillbeblockedbuttheadjustmentofthe setpointsandthealterationoftherecipesremainreleased 2 Enablestotallocking leavingonlyaccesstothefunctionsofthefacilitatedmenuava...

Страница 8: ...ols WARRANTY FULL GAUGE CONTROLS Products manufactured by Full Gauge Controls as of May 2005 have a two 02 year warranty as of the date of the consigned sale as stated on the invoice They are guarante...

Отзывы: