It is the minimum temperature that the instrument can achieve during the fast freezing
It is the duration of the fast freezing process.
It is the control temperature to prevent moisture condensation of the air in the door. When
the temperature of sensor S3 (door) is greater than the value set in this function, the
resistance of the door will be turned off.
It is the temperature difference between OFF and RELIGURE the resistance of the door
to avoid condensation.
Above this temperature, in addition to the visual alarm
[aC2,]
and buzzer indications,
the loads driven by the outputs will be turned off. If the S3 sensor input is configured
[,F57]
for another function this alarm is disable. This alarm is ignored until the
instrument reaches the control temperature for the first time and the time set in
[,F83]
is exceeded.
For the loads to be switched on again, the temperature of sensor S3 (condenser) should
drop to the value set in
[,F74]
minus the value set in this parameter. In this condition,
the process proceeds to the refrigeration step.
It is the temperature of the condenser above which the instrument will indicate high visual
alarm
[aC1,]
and audible (buzzer). If the sensor input S is set
[,F57]
to another
function this alarm is deactivated. This alarm is ignored until the instrument reaches the
control temperature for the first time and the time set in
[,F83]
is exceeded.
[,f69]
[,f70]
[,f71]
[,f72]
[,f73]
[,f74]
[,f75]
[no,,]
999
min.
2
-50 (-58)
75.0 (167)
°C (°F)
-25 (-13)
[no,,]
999
min.
[no,,]
-50 (-58)
75.0 (167)
°C (°F)
30.0 (86)
0.1 (1)
20.0 (36)
°C (°F)
3.0 (5)
[no,,]
75.0 (167)
°C (°F)
75.0 (167)
0.1 (1)
20.0 (36)
°C (°F)
3.0 (5)
[no,,]
75.0 (167)
°C (°F)
75.0 (167)
Temperature limit for Fast Freezing
Fast Freezing time
Desired temperature for anti-condensation (sensor
heating setpoint 3) if
[,f57]
=
[,,11]
and
[,f77]
= 3
Differential control for anti-condensation (S3) if
[,f57]
=
[,,11]
and
[,f77]
= 3
Maximum temperature at condenser (S3) to shut
down control outputs if
[,f57]
=
[,,11]
Control differential for maximum condenser
temperature (hysteresis) if
[,f57]
=
[,,11]
[,f76]
High temperature alarm on condenser (S3) if
[,f57]
=
[,,11]
[,f78]
[,f77]
[,,,0]
- Lamp: Controls the illumination.
[,,,1]
- Alarm: Activates the output during the occurrence of alarms of the functions
[,F78]
,
[,F79]
,
[,F80]
and
[,F81]
.
[,,,2]
- Door resistance (without S3 sensor): Door resistance remains on regardless
of door temperature. The resistance is switched off only during the occurrence of the
alarms of the
[,F78]
,
[,F79]
,
[,F80]
and
[,F81]
functions. The buzzer does
not fire during alarms.
[,,,3]
- Door resistance with sensor S3, if
[,F57]
=
[,,11]
: The resistance of
the door to prevent condensation is controlled by the temperature of sensor S3 and the
values set in functions
[,F72]
and
[,F73]
. The output is turned off at the occurrence
of alarms on the
[,F78]
,
[,F79]
,
[,F80]
functions. The buzzer does not fire during
alarms.
Note.: In the
[,,,1]
,
[,,,2]
and
[,,,3]
options, the LED indicator for the
light output is constantly off.
3
0
0
-
[no,,]
999
H
[no,,]
Operating Mode Lamp Output / Alarm / Door
Resistance
2
-
2
[no,,]
[,f67]
[,f68]
0
999
min.
20
0
999
min.
10
CELSIUS (FAHRENHEIT)
FUN
MIN
MAX
UNIT.
DEFAULT
DESCRIPTION
FUNCTION
If the room sensor (sensor S1) is disconnected or out of its measuring range, the
compressor will turn on and off according to the setup configured in these functions.
Compressor ON time in case of error on sensor S1
(room)
Compressor OFF time in case of error on sensor S1
(room)
When the instrument is switched on, the compressor will be kept off for some time, thus
delaying the beginning of the process. The purpose of this is to avoid peaks in electric
power demand when power returns after a power fault and many devices are connected
to the same mains. To do this, just set different times for each device.
Compressor delay time when powering the
controller
Maximum time of compressor operation without
reaching the desired temperature (setpoint)
This is the alarm that indicates when the compressor is active for longer than the
configured time set by this function, without reaching the setpoint.
This is the temperature difference in the current setpoint to activate the alarm (buzzer) for
LOW temperature.
Example: Setpoint =
[,,3.0]
,
[,f79]
=
[,,2.0]
. In this case, the alarm will only be activated
if the room temperature is lower than
[,,1.0]
(
[,,3.0]
-
[,,2.0]
).
This is the temperature difference in the current setpoint to activate the alarm (buzzer) for
HIGH temperature.
Example: Setpoint =
[,,3.0]
,
[,f80]
=
[,10.0]
. In this case, the alarm will only be activated
if the room temperature higher than
[,13.0]
(
[,,3.0]
+
[,10.0]
).
When the door is opened, the
[OPEN]
message will appear on the display and the open
door timer starts. If this time is longer than the set time with this function, the audible alarm
(buzzer) will be activated.
This function is used to stop the alarm for a certain period, due to a possible increase in
temperature.
During the time set in this function, the alarm remains off, waiting for the system to start
working.
When defrost is concluded by time and not by temperature, the user is alerted by a
blinking dot on the lower right corner of the display
(
[,,,,*]
).
With this function enabled, setups are protected against unauthorized changes, and are
available for viewing only. In this state, when trying to change these values, a
[LOC,,]
message will be displayed.
Note: To activate or deactivate the functions lock, please refer to item 9.3
It allows and configures the functions lock; this function may operate in the following
ways:
[no,,]
Does not allow functions lock;
[,,,1]
Allows a partial lock, where the control functions will be locked but the change of
presets is allowed;
[,,,2]
Allows a full lock leaving only the access to the functions of the quick access
menu available.
Note: To activate or deactivate the functions lock, please refer to item 9.3
Minimum room temperature alarm relative to the
setpoint
Maximum room temperature alarm relative to the
setpoint
Door opening time until the alarm is activated
Temperature alarm delay
Alarm delay when powering the controller
Indication to defrost terminated by time
Functions Lock
Time for functions lock