Full Boar SD4000IRS Скачать руководство пользователя страница 6

6

•   The generator is designed to give safe and dependable service if operated according to 

instructions.

•   Read and understand the Owner’s Manual before operating the generator. Failure to do 

so could result in personal injury or equipment damage.

•   Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well 

ventilated area with the engine stopped.

•   Keep away from cigarette, smoke and sparks when re-fuelling the generator. Always 

refuel in a well ventilated location.

•   Prevent the spilling of fuel as this may also ignite with the hot motor. Wipe up spilled 

gasoline at once. Never refuel whilst the engine running.

•   Connections for standby power to a building’s electrical system must be made by a 

qualified electrician and must comply with all applicable laws and electrical codes. 

Improper connections can allow electrical current from the generator to back feed 

into the utility lines. Such back feed may electrocute utility company workers or others 

who contact the lines during a power outage, and when utility power is restored, the 

generator may explode, burn, or cause fires in the building’s electrical system.

•  Store the generator in a dry area away from inflammable liquids.
•   Always make a pre-operation inspection before you start the engine. You may prevent an 

accident or equipment damage.

•   Place the generator at least 1m (3ft) away from buildings or other equipment during 

operation. ALWAYS operate generator a minimum of 2 meters from any conductive 

surface eg. metals.

•  Persons who are fitted with a heart pacemaker,  or similar medical conditions should take 

care when using this device. Even the extra low voltage of the Battery charging output 

should not be handled by a person with medical conditions as or similar to the above.

•   Operate the generator on a level surface. If the generator is tilted, fuel spillage may 

result.

•  Do not operate in a hazardous location. Such areas include where there is a risk of 

explosion of petrol fumes, leaking gas or explosive dust.

•   Know how to stop the generator quickly and understand operation of all the controls. 

Never permit anyone to operate the generator without proper instructions.

•   Keep children and pets away from the generator when it is in operation.
•   Keep away from rotating parts while the generator is running.
•   The generator is a potential source of electrical shocks when misused; do not operate 

with wet hands.

SAFETY WARNINGS FOR GENERATORS 

IMPORTANT!

 When using the equipment, a few safety precautions must be 

observed to avoid injuries and damage. Please read the complete operating manual 

with due care. Keep this manual in a safe place so that the information is available at 

all times. If you give the equipment to any other person, give them these operating 

instructions as well.
We cannot accept any liability for damage or accidents which arise due to a failure 

to follow these instructions and the safety information.

Содержание SD4000IRS

Страница 1: ...follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference 0620 INVERTER GENERATOR 4000W MAX POWER 3500W RUNNI...

Страница 2: ...RUN CHOKE 6 Routine maintenance cover 7 Oil access cover 8 AC sockets 9 Funnel 10 Overload indicator LED 11 Output indicator LED 12 Oil alert indicator LED 13 Economy throttle switch 14 DC socket 15 D...

Страница 3: ...12V DC 8A 5V DC 2 1A 1 0A AC 240V AC 240V OFF ON AC SW PARALLEL OPERATION OUTLETS OVERLOAD OUTPUT OFF RUN CHOKE ON OFF 4 4 3 KNOW YOUR PRODUCT cont 10 18 17 11 26 21 22 23 24 12 13 20 14 15 19 16 1 3...

Страница 4: ...02 INTRODUCTION Page 05 SAFETY INSTRUCTIONS Page 05 EXPLANATION OF RISKS Page 08 PRE OPERATION CHECK Page 12 OPERATION Page 14 MAINTENANCE Page 20 TRANSPORTING STORAGE Page 23 TROUBLE SHOOTING Page 24...

Страница 5: ...mage SAFETY INSTRUCTIONS ELECTRICAL SAFETY Read and understand the manual prior to operating this tool Save these instructions and other documents supplied with this tool for future reference The petr...

Страница 6: ...m 3ft away from buildings or other equipment during operation ALWAYS operate generator a minimum of 2 meters from any conductive surface eg metals Persons who are fitted with a heart pacemaker or simi...

Страница 7: ...ian before connecting the grounding terminal or when using the generator for applications other than direct connection of appliances such as connection to a caravan WARNING The output of this generati...

Страница 8: ...well ventilated area Make sure hands are dry before touching unit Placing generator on or against highly conductive surface such as a steel walkway or metal roof Accidental leakage of electrical curre...

Страница 9: ...speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the engine t...

Страница 10: ...rator components Contact with hot surfaces such as engines exhaust components could result in serious burns During operation touch only the control surfaces of the generator Keep children away from th...

Страница 11: ...peration and controls of the generator Know how to shut it off quickly Equip area of operation with a fire extinguisher certified to handle gasoline or fuel fires Keep children or others away from the...

Страница 12: ...ick in the filler hole without screwing it in and then removing it again fig 2 4 If the oil level is below the end of the dipstick refill using funnel 9 until it registers on the halfway mark of the d...

Страница 13: ...when refuelling Spilled fuel or fuel vapour may ignite If any fuel is spilled make sure the area is dry before starting the engine WARNING Never refuel the inverter generator while the engine is runni...

Страница 14: ...moisture collecting on in or around the generator 1 Turn the engine control switch 5 to the CHOKE position fig 6 2 Hold the generator steady with one hand With the other hand pull slightly on the reco...

Страница 15: ...M will increase according to the load applied 2 To run the inverter at maximum power and RPM press the efficiency mode switch to the OFF O position Upper level allowed OFF RUN CHOKE 91 R O N U nl ea d...

Страница 16: ...ights the overload indicator LED red 10 may damage the generator Marginal overloading that temporarily lights the overload indicator LED red 10 may shorten the service life of the generator Stop the e...

Страница 17: ...rning Fig 13 AC Applications Check the total rating of the appliance to be connected and ensure the rating of the appliance s does not exceed the rating of the inverter generator 1 Make sure the outpu...

Страница 18: ...or the battery may occur 2 Connect the charging cable and clamp set 18 plug to DC socket 14 fig 16 The battery will begin charging 3 When disconnecting remove the plug from the inverter generator bef...

Страница 19: ...ngine and attached devices run evenly before plugging in the next load Maximum Power in Parallel Operation 7 2kVA Rated Power in Parallel Operation 6 3kVA Limit operation time to 3 seconds for load re...

Страница 20: ...ent parts which are not of equivalent quality may damage the generator REGULAR SERVICE PERIOD 1 EACH USE FIRST MONTH OR 20HRS EVERY 3 MONTHS OR 50 HRS EVERY 6 MONTHS OR 100 HRS EVERY YEAR OR 200 HRS I...

Страница 21: ...s Do not throw it in the trash or pour it on the ground Air cleaner service A dirty air cleaner will restrict air flow to the carburettor To prevent carburettor malfunction service the air cleaner reg...

Страница 22: ...rk plugs To ensure proper engine operation the spark plug must be properly gapped and free of deposits 1 Remove the routine maintenance cover 6 to gain access to the spark plug 2 Take out the spark pl...

Страница 23: ...e taken to prepare the inverter for any storage 1 Be sure the storage area is free of excessive humidity and dust 2 Completely drain the fuel from the tank Start the engine and operate it in the idle...

Страница 24: ...rter a few times to ensure that fuel enters the carburettor Is the spark plug working Replace spark plug Contact Ozito customer service yes yes yes yes no no no no no no Engine will not start There is...

Страница 25: ...after the unit is turned off Exhaust contains poisonous carbon monoxide Do not operate generator in confined area Do not parallel connect other cables to receptacles use special jack or it may cause a...

Страница 26: ...facilities exist Check with your local council authority for recycling advice Recycling packaging reduces the need for landfill and raw materials Reuse of recycled material decreases pollution in the...

Страница 27: ...s not cover components that have been subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain the inverter generator as instructed in this manual N...

Страница 28: ...ilable to you under law The warranty covers manufacturer defects in materials workmanship and finish under normal use 1 YEAR WARRANTY Your product is guaranteed for a period of 12 months from the orig...

Отзывы: