![Full Boar SD4000IRS Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/full-boar/sd4000irs/sd4000irs_instruction-manual_2345212015.webp)
15
KNOW YOUR PRODUCT
Efficiency mode
The inverter is equipped with an Economy throttle switch (13) to minimize fuel
consumption. In efficiency mode, the inverter will sense the load and adjust the
engine RPM to the current load requirements. Efficiency mode should be used
only after the inverter has been warmed up to operating temperature.
1.
To turn on the efficiency mode, press the switch to
the ON (I) position (fig. 12). If no load is present,
the inverter RPM will drop down to an idle speed.
As a load is applied, the inverter will sense the load
and engine RPM will increase according to the load
applied.
2.
To run the inverter at maximum power and RPM,
press the efficiency mode switch to the OFF (O) position.
Upper
level
allowed
OFF
RUN
CHOKE
91 RON
Unleaded
Petr
ol
OFF
ON
ECONOMY
12V DC 8A
5V DC
2.1A
1.0A
AC 240V
AC 240V
OFF
ON
AC SW.
PARALLEL
OPERATION OUTLETS
OVERLOAD
OUTPUT
OFF
RUN
CHOKE
ON
OFF
+
Fig. 11
Fig. 12
OPERATION (cont.)
Stopping the engine
In normal operation
1.
Switch off the connected equipment and pull out the plug.
2.
Turn the AC switch (22) to OFF (O) (fig. 10).
3.
Turn the engine control switch (5) to the OFF
position (fig. 11).
In emergency situation
If there is an emergency and the inverter must be stopped quickly, move the
engine control switch (5) to the OFF position immediately.
OFF
RUN
CHOKE
OFF
ON
AC SW.
OFF
ON
AC SW.
OFF
RUN
CHOKE
Fig. 10