SPECIFICATIONS

MECHANICAL DATA

100%-1%,0%

 

E477042

LiFePO4

FHSAC1-UNV-40L

Important Safety Instructions

When using electrical equipment and this lighting device basic safety precaution should 
be followed at all times including but not limited to the following: 

 

 

·CAUTION

: Do not let power supply cords touch hot surfaces.

 

·CAUTION

: Do not mount near gas or electric heaters.

 

·

IMPORTANT:

 

An un-switched AC power source of 120VAC to 277VAC is required for the

·This device is designed for use in fixtures listed for 

dry and damp locations

PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY

·CAUTION: 

Make sure all electrical connections conform to the National Electrical Code and all applicable local 

regulations.

·CAUTION: 

Battery is rechargeable LiFePO4 type and must be recycled or disposed of properly.

·CAUTION:

 Do not use this emergency driver with accessory equipment other than recommended by 

manufacturer; failure to follow this may cause an unsafe condition. Servicing should only be performed 
by qualified service personnel.  

 

·CAUTION: 

Do not use this emergency driver for other than intended use.

·CAUTION: 

Equipment should be mounted in locations and at heights where it will not readily be subjected 

to tampering by unauthorized personnel.   

yellow/black and white leads.

·

IMPORTANT: A switched or un-switched AC power source of 120VAC to 277VAC is acceptable

for the black lead only.

TESTING SYSTEM: 

The emergency battery requires a minimum charge time of one (1) hour before testing the circuit.  

A minimum of twelve (12) hours is required for a full charge.    

ASSEMBLY and FIELD INSTALLATION WIRING:  WARNING: 

AC power must be off before proceeding with assembly, 

installation or servicing of emergency driver. Additionally ensure that the battery is disconnected (Battery Switch set to OFF).   

RATED EMERGENCY OPERATION: 

Ninety (90) minutes for the 10W load or one hundred eighty (180) minutes for the 5W

load. The 10W or 5W option is determined by the position of Dip Switch 1 (Emergency Power Selection Switch).    

Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years from the date of manufacture when properly installed 
and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com. 
Specifications subject to change without notice.

BATTERY DISABLE PROCEDURE:

 Unit must be powered within 6 months. To ship a fixture with the battery 

connected without draining the battery the procedure is:

1.   Driver is installed in a fixture.
2.   Battery is switched to the “ON” position.
3.   Fixture is powered and tested.
4.   Fixture is un-powered, the unit enters EM mode.
5.   Battery is switched to “OFF”, wait about 3 seconds then switch the battery back to the “ON” position.

Note:

 Not recommended for installations where unit will be without power for more than 6 months.

Содержание HOTSPOT LED FHSAC1-UNV-40L

Страница 1: ...s Any LED module designed to accept input voltage range of 11 55VDC and can operate up to current of 250 1400mA Battery Type LiFePO4 6 4VDC Part FHSBATL2 3 2 Battery Capacity Available Max Case Temperature 3200mAh 62 C 143 6 F Battery Recharge Time 12 Hours Page 1 of 7 Driver Type FHSAC1 UNV 40L SPECIFICATIONS 2017 735 1 Rev A MECHANICAL DATA Power Factor 0 9 20 THD 5W or 10W Initial Emergency Mod...

Страница 2: ...igure 2 Figure 1 700 R SET Curve 400 500 600 700 Io mA 200 300 0 4 8 12 16 20 Resistor Value Kohm 0 10V Linear Dimming Curve 40 60 80 100 o Value 0 20 0 1 2 3 4 5 6 7 8 9 10 Io Dimming Voltge V 0 1 2 3 4 5 6 7 8 9 10 60 80 100 e 0 10V Log Dimming Curve 0 20 40 Io Value Dimming Voltge V 800 1000 1200 1400 max mA 200 400 600 Io m Vo vs Io max Curve 10 20 30 40 50 Output Voltage V 90 Efficienc Vs Out...

Страница 3: ...2 88 90 Efficienc Vs Output Voltage at 277Vac 750mA 80 82 84 86 Efficienc 1000mA 1250mA 1400mA 20 25 30 35 40 45 50 55 Output Voltage V 80 100 120 140 e Khrs Lifetime vs Tcase 0 20 40 60 50 55 60 65 70 75 80 85 Lifetime Tcase C 6 8 10 THD Vs Output Power 277V 60Hz 230V 50Hz 0 2 4 20 25 30 35 40 THD Output Power W 120V 60Hz p 80 90 100 110 Io vs Ext NTC Curve 10 20 30 40 50 60 70 80 Io Ratio 0 0 2 ...

Страница 4: ...D light source illuminates as intended A full discharge test shall be conducted once a year the LED light source shall illuminate for a minimum of ninety 90 minutes for the 10W load Dip Switch 1 is set to the ON position or one hundred eighty 180 minutes for 5W load Dip Switch 1 is set to the OFF position If Dip Switch 2 Self Diagnostic Switch is set to the ON position The self diagnostic feature ...

Страница 5: ...rve LED NTC Thermal Protection LED Indicators Status EM Driver Status Mode Solid Green System OK AC OK Self diagnostic Enabled or Disabled Slow Flashing Red 4s on 1s off Battery not detected check battery switch or connection Flashing Red 1s on 1s off Battery Failure replace battery Flashing Green 1s on 1s off Self Diagnostic test underway Fast Flashing Red 0 1s on 0 1s off Abnorm al driver perfor...

Страница 6: ... O ring Seal Mechanical Data Tolerance 0 5 12 7mm General Specifications FHS EXT 48 TST Light Push Button Test Switch Extension Wire Length Ambient Operating Temperature Range Warranty 48 25 C to 55 C 5 years 48 Extension Mechanical Data Tolerance 0 5 12 7mm SPECIFICATIONS MECHANICAL DATA 100 1 0 E477042 LiFePO4 FHSAC1 UNV 40L Page 6 of 7 2017 735 6 Rev A Fulham extends a limited warranty to the or...

Страница 7: ...n switched AC power source of 120VAC to 277VAC is acceptable for the black lead only TESTING SYSTEM The emergency battery requires a minimum charge time of one 1 hour before testing the circuit A minimum of twelve 12 hours is required for a full charge ASSEMBLY and FIELD INSTALLATION WIRING WARNING AC power must be off before proceeding with assembly installation or servicing of emergency driver A...

Отзывы: