Fulham HOTSPOT LED FHSAC1-UNV-40L Скачать руководство пользователя страница 1


      Output Wattage: 40W Max.

      Universal Voltage: 120-277V  , 50/60Hz

~

      Output Current: 250-1400mA

 

    

Output voltage range of 11-55V

General Specifications

Input  Voltage 
Input  Current 
Input Power

Standby Input Power 

Output Current
Output Voltage Range
Output Power

Number of Output Channels

RFI/EMI  
Output Type

Ambient Operating Temperature Range

Input Surge Protection

Protections

Service Life

Approvals / Class 

120-277VAC, 50/60Hz 

0.43A  @ 120VAC 
54W

<0.85W
Constant Current 

11-28VDC ( 250-1400mA ) , 11-40VDC ( 250-1000mA ) , 11-55VDC ( 250-730mA )
40W Max. ( Figure 1 )

1 Channel

FCC Part 15A Non-Consumer , EN55015
LED Class 2

 0°C to 50°C(32 to 122°F) 

Line-Neutral 3kV , Line & Neutral-Gound 6kV , Ring Wave ANSI/IEEEC62.41
Input Current Protection
Output Open Circuit Protection 

50,000 hours
RoHS , cULus LISTED, CE, CEC , Dry or Damp Locations

250-1400mA [ TPSB 100 ( Program Box ) , Figure 1 ] ; Record New Setting On 1"x0.5" Label

This Driver Will Operate The Following LED Modules: Any LED module designed to accept input voltage range of 11-55VDC and can operate 
up to current of 250-1400mA.

Battery Type

LiFePO4 6.4VDC (Part# FHSBATL2-3.2)

Battery Capacity Available  

Max. Case Temperature

3200mAh

62°C(143.6°F)

Battery Recharge Time

12 Hours

Page 1 of 7

Driver Type

FHSAC1-UNV-40L

SPECIFICATIONS

2017-735-1 Rev A

MECHANICAL DATA

Power Factor

>0.9
<20%

THD

5W or 10W Initial @ Emergency Mode

Sound Rating

A

Over Temperature Protection 

Overload Protection 

Dimming Controller Type / Dimming Range

0-10V / 100% - 1% ,0%( Figure 2 ) / Custom Dimming Curve / Dimmed To Off

100%-1%,0%

 

E477042

LiFePO4

 

    

Linear case with side leads

MECHANICAL DATA

Case Tolerance=±0.02" 

Tc

0.79"[20mm]

3.32"[84.45mm]

LED Driver with integrated emergency backup

( Min. 180 Minutes Runtime @ 5W Setting , Min. 90Minutes Runtime @ 10W Setting )

 

    

Fulham extends a limited warranty to the original purchaser or first user for a period of 5 years from the date of manufacture when properly installed 
and operated under normal conditions of use. For complete terms and conditions, please refer to the Warranty Center at www.fulham.com. 
Specifications subject to change without notice.

Содержание HOTSPOT LED FHSAC1-UNV-40L

Страница 1: ...s Any LED module designed to accept input voltage range of 11 55VDC and can operate up to current of 250 1400mA Battery Type LiFePO4 6 4VDC Part FHSBATL2 3 2 Battery Capacity Available Max Case Temperature 3200mAh 62 C 143 6 F Battery Recharge Time 12 Hours Page 1 of 7 Driver Type FHSAC1 UNV 40L SPECIFICATIONS 2017 735 1 Rev A MECHANICAL DATA Power Factor 0 9 20 THD 5W or 10W Initial Emergency Mod...

Страница 2: ...igure 2 Figure 1 700 R SET Curve 400 500 600 700 Io mA 200 300 0 4 8 12 16 20 Resistor Value Kohm 0 10V Linear Dimming Curve 40 60 80 100 o Value 0 20 0 1 2 3 4 5 6 7 8 9 10 Io Dimming Voltge V 0 1 2 3 4 5 6 7 8 9 10 60 80 100 e 0 10V Log Dimming Curve 0 20 40 Io Value Dimming Voltge V 800 1000 1200 1400 max mA 200 400 600 Io m Vo vs Io max Curve 10 20 30 40 50 Output Voltage V 90 Efficienc Vs Out...

Страница 3: ...2 88 90 Efficienc Vs Output Voltage at 277Vac 750mA 80 82 84 86 Efficienc 1000mA 1250mA 1400mA 20 25 30 35 40 45 50 55 Output Voltage V 80 100 120 140 e Khrs Lifetime vs Tcase 0 20 40 60 50 55 60 65 70 75 80 85 Lifetime Tcase C 6 8 10 THD Vs Output Power 277V 60Hz 230V 50Hz 0 2 4 20 25 30 35 40 THD Output Power W 120V 60Hz p 80 90 100 110 Io vs Ext NTC Curve 10 20 30 40 50 60 70 80 Io Ratio 0 0 2 ...

Страница 4: ...D light source illuminates as intended A full discharge test shall be conducted once a year the LED light source shall illuminate for a minimum of ninety 90 minutes for the 10W load Dip Switch 1 is set to the ON position or one hundred eighty 180 minutes for 5W load Dip Switch 1 is set to the OFF position If Dip Switch 2 Self Diagnostic Switch is set to the ON position The self diagnostic feature ...

Страница 5: ...rve LED NTC Thermal Protection LED Indicators Status EM Driver Status Mode Solid Green System OK AC OK Self diagnostic Enabled or Disabled Slow Flashing Red 4s on 1s off Battery not detected check battery switch or connection Flashing Red 1s on 1s off Battery Failure replace battery Flashing Green 1s on 1s off Self Diagnostic test underway Fast Flashing Red 0 1s on 0 1s off Abnorm al driver perfor...

Страница 6: ... O ring Seal Mechanical Data Tolerance 0 5 12 7mm General Specifications FHS EXT 48 TST Light Push Button Test Switch Extension Wire Length Ambient Operating Temperature Range Warranty 48 25 C to 55 C 5 years 48 Extension Mechanical Data Tolerance 0 5 12 7mm SPECIFICATIONS MECHANICAL DATA 100 1 0 E477042 LiFePO4 FHSAC1 UNV 40L Page 6 of 7 2017 735 6 Rev A Fulham extends a limited warranty to the or...

Страница 7: ...n switched AC power source of 120VAC to 277VAC is acceptable for the black lead only TESTING SYSTEM The emergency battery requires a minimum charge time of one 1 hour before testing the circuit A minimum of twelve 12 hours is required for a full charge ASSEMBLY and FIELD INSTALLATION WIRING WARNING AC power must be off before proceeding with assembly installation or servicing of emergency driver A...

Отзывы: