![FULGOR DPA 4 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/fulgor/dpa-4/dpa-4_user-and-installation-manual_2344917009.webp)
9
Features can be modified without any notice
V2020320
BRIDGE USE
To use this mode, two BF inputs must be connected in parallel and use a “+” of a output
channel and a “-“ of the other (see image). Do not drop under 8Ω impedance.
OPTIONAL TR150 OUTPUT TRANSFORMER
TR150 is a autotransformer that allows you to adjust the DPA output impedance with
lines that have different impedances. This allows an optimal power transfer.
The input impedance is 4Ω, while on the output we can have constant impedance at 4Ω-
8Ω-16Ω or high impedance lines at 50V-70V-100V. In the case of using TR150, the number of
transformers varies according to number of power unit outputs: we can add maximum 4 TR1500
and it is NOT possible to use the transformer in the bridge configuration.