![FULGOR DPA 4 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/fulgor/dpa-4/dpa-4_user-and-installation-manual_2344917006.webp)
6
Features can be modified without any notice
V2020320
POWER SUPPLY
The device is intended for operating with 230VCA – 50/60Hz. In case of power disfunction,
check the external protection fuses and eventually replace them with others of same calibration;
if one of the fuses burns out immediately, do not insist and have the device checked by a
specialized FULGOR SERVICE laboratory.
Alway remove the plug from 230VAC electric socket before removing the fuses and, in any case,
before opening the carpentry.
SPEAKERS CONNECTION
DPA is equipped with a double terminal block for each 4-way output channel for
connection to constant impedance lines.
It is necessary to be sure about the real impedance value of the line you are connecting
(minimum value 4Ω) to protect yourself from the malfucntion of the amplifier and to grant the
maximum system efficiency. To get this, each speaker must be without transformer and must
be connected in “series” or in “series-parallel” groups; in any case, the speakers must have the
same power (or greater). By using the TR150 it is possible to connect load of 4Ω-8Ω-16Ω o 50V-
70V-100V, always keeping in mind the rules above mentioned.
TECHNICAL CHARACTERISTICS
Description
Multichannel power amplifier
Type
4 channels 150W
Maximum rated power
RMS 4x150W – peak 4x300W
Bridge power (8Ω)
RMS 2X300 – peak 2X600
Cooling
Air cooling with dissipator
Protections
Short circuit on output and anti
bump on power on/off
Passband
20 – 22.000Hz ±2dB
BF line inputs
4 XLR – 10KΩ
Gain inputs
0-6-9-12dB
Outputs
4Ω
Power IN
230VAC / 50-60Hz IEC
Out
230VAC / 50-60Hz IEC
External volume control
External connection provided
Mechanics
2U Standard rack
Dimensions
483x 290 x 90mm
Weight