EN
13
Turning off/changing the timer
• The timer can be changed or turned off at any time by turning
on the touch display again, if no cooking area is on, and
pressing the + and - buttons simultaneously to select the timer.
At this point, set it to “0” by pressing the - button, to turn it
off, or by pressing the + button to increase the time setting.
• The independent timer remains active even when the On/
Off button is pressed
Programming the timer for the cooking areas
By turning on the touch display, you can program an
independent timer for each cooking area.
• At least one cooking area must be on and set to a certain
level.
• By pressing the + and - buttons simultaneously, you can set
a countdown for turning off the cooking area. There are
illuminated clock icons
(13)
next to the display of the cooking
area. To set the timer on a cooking area when there are
more than one cooking area on, you must press the + and -
buttons simultaneously. You will note that the clock icon will
light and move to successive cooking areas each time you
simultaneously press the + and - buttons.
• When the timer of the cooking area is selected, the related
clock icon near the display becomes brighter
(13)
. The timers
programmed for each cooking zone remain active.
• Other functions of the timer are the same as the independent
timer. To increase the time, use the + (plus) button.
• The beeping and flashing of the display stops:
a- Automatically after 2 minutes.
b- When you press the + or - buttons, the timer display turns off.
Error codes
Error codes are displayed by the 7-segment display with “E” or “ER” plus the error number.
Error message
Description
Possible error reason
Troubleshooting
“flash”
Control is detecting a button
being activated for more than 10
seconds.
Water or cooking utensils on
the glass above the control unit
Cleaning of the operational
surface
Er 22
Defective Key evaluation . Control
unit cuts off after 3.5 - “7.5 sec.
Short-circuit or no continuity in
the range of the key evaluation
Exchange control unit
Er20
Flash-failure
Faulty microcontroller
Exchange control unit
Er36
NTC value is not
within its specification
(value < 200mV or > 4.9V;
control unit cuts off
Short-circuit or cut-off at NTC
Exchange control unit
Er31
Configuration data incorrect
Configuration of induction
necessary
New Configuration
Er47
Communication error between TC
and induction
None or faulty communication! Ensure that connection cable
is plugged on correctly and
functional.
E2
Overheating of the induction coils
Cooling down necessary
U400
Secondary voltage of the power
unit too high (primary > 300V).
Control unit cuts off after 1 sec
releasing a permanent tone.
Control unit is wrongly
connected
Connect to correct mains
voltage
E5
Error on filter board
Exchange filter board
E6
Error on power unit
Exchange power unit
E9
Coil temperature sensor defective
Exchange temperature sensor