XG Series User's Guide
Chapter 5 Command Reference
System Operations and Display Commands
365
4)
machine_state
State of the device
RUNNING
: The device is active.
FALLBACK
: The device is into fallback state.
5)
access_direction
Direction where a device is installed in.
front access
: The device should be installed forward. (XG0440DC)
rear access
: The device should be installed backward. (XG0440DCR)
6)
power_redundancy
State of the redundant power unit.
single
: The device has no redundant power unit.
redundant
: The device has a redundant power unit.
7)
PSU1 state
State of the power unit (PSU1).
PSU2 state
Type of the power unit (PSU2).
NORMAL
: The power unit works normally.
NO PRESENT
: The power unit is not installed.
NO POWER
: The power unit has been turned off.
FAIL
: The power unit has been abnormal.
UNKNOWN
: The power unit is invalid type.
WARNING
: The power unit has been incorrectly mounted.
8)
PSU1 type
Type of the power unit (PSU1).
PSU2 type
Type of the power unit (PSU2).
AC
: The power unit is AC.
--
: The power unit is not installed or invalid type.
9)
power_consumption
Power consumption of the device.
10)
FAN state
State of the fan module 1.
NORMAL
: The fan module works normally.
FAIL
: The fan module has been abnormal.
NO PRESENT
: The fan module is not installed.
UNKNOWN
: The fan module is invalid direction.
WARNING
: The fan module has been incorrectly mounted.
11)
inspiration_state
State of environment temperature monitor.
internal_state
State of device inside temperature monitor.
NORMAL
: The temperature is normal.
WARNING
: The device changes to a high temperature state.
ALARM
: Thermal alarm occurs in the device.
12)
State of changing thermal state
warning time
: The time when a device changed in a high temperature state.
recover time
: The time when a device returned to a normal state.