- 62 -
Line
Function
Setting range
or display
Setting
increment
Basic
setting
Generator diagnosis
8400
I
Compressor 1
O
ff
, On
O
ff
8402
I
Electrical resistance
fl
ow 1
O
ff
, On
O
ff
8403
I
Electrical resistance
fl
ow 2
O
ff
, On
O
ff
8406
I
Condenser pump
O
ff
, On
O
ff
8407
S
Speed condenser pump
0...100%
--
8410
U
Return temp HP
0... 140 °C
--
Setpoint (
fl
ow) HP
--
8412
U
Flow temp HP
0... 140 °C
--
Setpoint (
fl
ow) HP
--
8413
U
Compressor modulation
0... 100%
--
8414
I
Modulation electric
fl
ow
0... 100%
--
8425
S
Temp di
ff
condensor
-50... 140 °C
--
8450
S
Hours run compressor 1
00:00
--
8454
S
Locking time Heat Pump
Reset ? (no, yes)
0... 2730 h
--
8455
S
Counter number of locks HP
Reset ? (no, yes)
0... 65535
--
8456
S
Hours run electrical
fl
ow
Reset ? (no, yes)
0... 2730 h
--
8457
S
Start counter electrical
fl
ow
Reset ? (no, yes)
0... 65535
--
8458
I
State smart grid
Draw disabled, Draw free,
Draw wish, Draw forced
Draw free
8460
I
Heat pump throughput
0... 65535 l/min
--
Diagnostics consumers
8700
U
Outdoor temperature
-50... 50 °C
--
8701
U
Outdoor temp min
Reset ? (no, yes)
-50... 50 °C
50 °C
8702
U
Outdoor temp max
Reset ? (no, yes)
-50... 50 °C
-50 °C
8703
I
Outdoor temp attenuated
Reset ? (no, yes)
-50... 50 °C
--
This is the average of the outdoor temperature over a 24-hour period.
This value is used for automatic Summer / Winter switchover (line 730).
8704
I
Outdoor temp composite
-50... 50 °C
--
The mixed outdoor temperature is a combination of the current outdoor temperature and the average outdoor
temperature calculated by the regulator. This value is used for calculating the initial temperature.
8730
I
Heating circuit pump, circuit 1
O
ff
, On
O
ff
8731
I
Mixer valve HC1 open
O
ff
, On
O
ff
8732
I
Mixer valve HC1 closed
O
ff
, On
O
ff
8740
U
Room temperature 1
0... 50 °C
--
Room setting 1
20 °C
8743
U
Flow temperature 1
0... 140 °C
--
Flow temperature setpoint 1
--
8749
I
Room thermostat 1
No demand, Demand
No demand
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN