
- 56 -
Line
Function
Setting range
or display
Setting
increment
Basic
setting
Heat pump (HP)
2779
I
Pump speed max condenser pump cooling mode
70... 100 %
1 %
100 %
2793
I
Pump speed max condenser pump
70... 100 %
1 %
100 %
2803
S
Overrun time cond pump
8... 600 s
1 s
240s
2843
S
Compressor o
ff
time min
0... 120 min
1 min
8 min
2844
S
Switch-o
ff
temp max
8... 100 °C
1 °C
75 °C
2862
S
Locking time stage 2 / mod
0... 40 min
1 min
5 min
2873
S
Compressor mod run time
10... 600 s
1 s
240 s
2882
S
Release integr electric
fl
ow
0... 500 °Cmin
1 °Cmin
100 °Cmin
2884
S
Release el
fl
ow below OT
Electrical release - start-up with outdoor
temperature
-30... 30 °C
2 °C
2886
S
Compensation heat de
fi
cit
O
ff
, On,
Only with
fl
oor curing fct
O
ff
2907
S
Silent mode power max
--, 1... 100 %
1 %
--
2916
S
Max setpoint HP DHW charg
8... 80 °C
1 °C
--
2920
S
With electrical utility lock (EX1)
(
fi
g. 45, page 39
)
Locked (Blocked on standby),
Released
Released
Released
: HP = ON _ Back-up DHW = o
ff
_ 1
st
back-up HP = o
ff
_ 2
nd
back-up HP = o
ff
_ Boiler = ON
Locked (Blocked on standby)
: HP = o
ff
_ Back-up DHW = o
ff
_ 1
st
back-up HP = o
ff
_ 2
nd
back-up HP = o
ff
_
Boiler = ON
3026
S
Silent mode on
00:00... --:--
10 min
22:00
3027
S
Silent mode o
ff
00:00... --:--
10 min
07:00
3028
S
Silent mode speed incr start
-50... 50 °C
1 °C
8 °C
3029
S
Silent mode speed incr end
-50... 50 °C
1 °C
7 °C
Energy meter
3095 --> 3110 : Not used
3113
U
Energy brought in
Kwh
--
Cumulation of total consumed electrical energy.
Electrical energy consumed = Electrical energy absorbed by outdoor unit + electric energy absorbed by the heating
electrical backup and / or DHW electrical backup (if installed).
3121 --> 3123 : Not used
3124
U
Energy brought in heating 1 (N - 1)
Kwh
--
3125
U
Energy brought in DHW 1
Kwh
--
3126
U
Energy brought in cooling 1
Kwh
--
3128 --> 3130 : Not used
3131
U
Energy brought in heating 2 (N - 2)
Kwh
--
3132
U
Energy brought in DHW 2
Kwh
--
3133
U
Energy brought in cooling 2
Kwh
--
3135 --> 3137 : Not used
3138
U
Energy brought in heating 3 (N - 3)
Kwh
--
3139
U
Energy brought in DHW 3
Kwh
--
3140
U
Energy brought in cooling 3
Kwh
--
3142 --> 3144 : Not used
Note: "Energy" Counters increment as of 1 July each year.
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN