En-8

NOTES: 

•  This operation cannot be performed simultaneously with the Fan 

mode, Dry mode, and Powerful operation.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

 8.3.  10 °C Heat operation

10 °C Heat operation maintains the room temperature at 10 °C so as to 
prevent the room temperature to drop too low.

 

)

Press 

 to activate the 10 °C Heat operation.

The indoor unit will emit 1 short beep and [ 

 ] indicator on the 

indoor unit will turn on.

 

)

Press 

 to turn off the air conditioner. 

 ] indicator will turn off.

 

Indicator Lamp

TIMER

OPERATION ECONOMY

: Lighting 

: OFF

NOTES:

•  During the 10 °C Heat operation, only 

 is valid.

•  When the room temperature is warm enough, this operation will not 

perform.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

9.  SETTINGS ON INSTALLATION

9.1.  Remote controller custom code setting

By setting custom code of indoor unit and remote controller, you can 
specify the air conditioner which the remote controller controls.
When two or more air conditioners are in the room and you wish to 
operate them separately, set the custom code (4 selections possible).

NOTES: 

If custom codes is different between the indoor unit and the 

remote controller, the indoor unit cannot receive a signal from 
the remote controller.

How to set the remote controller custom code

1. 

 Press 

 until only the clock is displayed on the remote 

controller display.

2. 

 Press and hold

 

 

for more than 

5 seconds.

The current custom code will be 
displayed (initially set to A).

3. 

Press 

 to change the 

custom code between A

B

C

(

).

* Match the custom code on the display 
to the air conditioner custom code.

4. 

Press 

 again.

The custom code will be set. 
The display  will return to the clock display.

•  To change the air conditioner custom code, contact an authorized 

service personnel (initially set to A).

•   If you do not press any buttons for 30 seconds after the custom 

code is displayed, the display returns to the clock display. In this 
case, repeat the setting from step 2.

•  Depending on the remote controller, the custom code may return 

to A when replacing the batteries. In this case, reset the custom 
code as necessary. If you do not know the air conditioner custom 
code, try each code until you 

fi

 nd the code which operates the air 

conditioner.

10. CLEANING  AND  CARE

 

CAUTION

•  Before cleaning this product, be sure to turn it off and 

disconnect all the power supply. 

•  Before starting operation, make sure that the intake 

grille has been shut completely. Incomplete closing 

of the intake grille might have an effect on the proper 

working or performance of the air conditioner.

• If the 

fi

 lter cleaning involves high-place work, please 

consult the authorized service

 

personnel.

•  Do not touch the aluminum 

fi

 ns of heat exchanger 

built-in the indoor unit to avoid personal injury when 

you maintain the unit.

•  Do not expose the indoor unit to liquid insecticides or 

hair sprays.

•  Do not stand on slippery, uneven or unstable surfaces 

when you maintain the unit.

The frequency of the cleaning is as shown in the following table.

What to do

Frequency

Cleaning indoor unit body

When you notice

 Cleaning air 

fi

 lter

Every 2 weeks

Cleaning Ion deodorization 

fi

 lter

Every 3 months

Replacing Apple-catechin 

fi

 lter

(Model name: UTR-FA16)
Replacing Ion deodorization 

fi

 lter

(Model name: UTR-FA16-2)

Every 3 years

* The air cleaning 

fi

 lters are sold separately. When you replace them, 

please contact the store of purchase.

Cleaning indoor unit body

NOTES:

•  Do not use water hotter than 40 °C.
•  Do not use scouring cleanser, volatile solvents such as benzene or 

thinner.

1. 

Wipe the indoor unit body gently with a soft cloth moisten 

with warm water.

2. 

Wipe the indoor unit body gently with a dry and soft cloth.

 Cleaning air 

fi

 lter

1. 

Remove the Intake Grille.

Intake grille

Air 

fi

 lters

Indoor unit body

Rope

00_9378532090_OM.indb   8

00_9378532090_OM.indb   8

2020/8/31   16:43:49

2020/8/31   16:43:49

Содержание Suelo AGY25-KV

Страница 1: ... EMPLOI CLIMATISEUR Type àu sol Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo suelo Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo da pavimento Prima di u...

Страница 2: ...ng the power plug Then consult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning...

Страница 3: ...places or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any other electrical products or household belongings under this product Dripping condensation from this product might get them wet and may cause damage or malfunction of your propert...

Страница 4: ...each remote controller The setting must be done while the setting screen is displayed for each function The button is controllable only when the air conditioner is operating For Energy saving operation Refer to page 7 Activates or deactivates the Economy operation Battery loading and remote controller preparation R03 LR03 AAA x 2 5 7 6 4 8 1 2 3 1 3 Put batteries as shown in the figure above 4 Pre...

Страница 5: ...d down airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the timer or clock settin...

Страница 6: ...y setting C 3 Press to switch the temperature unit C F 4 Press to finish the setting If you do not press the button for 30 seconds the displayed temperature unit will be set 5 2 Airflow direction setting For details of the airflow ranges refer to Airflow direction range Up and down airflow direction setting Press to adjust the Up and down airflow direction Left and right airflow direction setting ...

Страница 7: ...be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer 6 TIMER OPERATIONS NOTES When indicator on the indoor unit blinks set the clock and timer again This blinking shows that the internal clock go wrong due to an interru...

Страница 8: ...wly NOTES In multi connection this function cannot be used Press to activate deactivate the Outdoor Unit Low Noise operation While the Outdoor Unit Low Noise operation is activated on the remote controller is displayed The setting is preserved even if the air conditioner is turned off Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Prog...

Страница 9: ...personnel initially set to A If you do not press any buttons for 30 seconds after the custom code is displayed the display returns to the clock display In this case repeat the setting from step 2 Depending on the remote controller the custom code may return to A when replacing the batteries In this case reset the custom code as necessary If you do not know the air conditioner custom code try each ...

Страница 10: ...t beyond the frame 10 Replace the air filter and close the intake grille Refer to steps 4 5 of Cleaning air filter Replacing Ion deodorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter 2 Remove the air filter Lift up the air filter and pull o...

Страница 11: ...for the outdoor unit refer to the outdoor unit installation manual 12 OPTIONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard indicator on the indoor unit will blink Res...

Страница 12: ...g set In this case the indoor unit fan may stop temporarily while the Cooling operation To cancel the Fan control for energy saving refer to page 7 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the set temperature In this case the ou...

Страница 13: ...of Auto restart Reset the clock and timer settings 10 Test run operation for authorized personnel only Press to quit the test run 3 8 times 10 times Fast Refrigerant leakage suspicion Blowing operation is performed to prevent the refrigerant from accumulating Open the windows to ventilate the room and contact an authorized service personnel Press the button to stop the buzzer sound 5 times 4 times...