![Fujitsu Suelo AGY25-KV Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/fujitsu/suelo-agy25-kv/suelo-agy25-kv_operation-manual_2343980008.webp)
En-7
7. ENERGY SAVING OPERATION
7.1. Economy operation
It saves more electricity than other operation modes by changing the set
temperature to a moderate setting.
)
Press
to activate/deactivate the Economy
operation.
[
] indicator on the indoor unit will turn on.
Indicator Lamp
TIMER
OPERATION ECONOMY
: Lighting
: OFF
Operation
mode
Room temperature
Cooling/Dry
Few degrees higher than the set temperature
Heating
Few degrees lower than the set temperature
NOTES:
• In the Cooling, Heating, or Dry mode, the maximum output of this
operation is approximately 70 % of usual operation.
• This operation cannot be performed during the temperature
monitoring by the Auto mode.
8. OTHER OPERATIONS
8.1. Powerful operation
In the Powerful operation, the air conditioner will operate at maximum
power and strong air
fl
ow to cool down or warm up the room quickly.
NOTES:
In multi connection, this function cannot be used.
)
Press
to activate/deactivate the Powerful operation.
When activated, the indoor unit will emit 2 short beeps.
When deactivated, the indoor unit will emit 1 short beep.
The Powerful operation will be turned off automatically in the following
situations:
• The Powerful operation runs for a certain amount of time and the
room temperature reaches the set temperature in the Cooling, Dry,
or Heating mode.
• 20 minutes after the Powerful operation has started.
NOTES:
• The air
fl
ow direction and the fan speed are controlled automatically.
• The Powerful operation cannot be performed simultaneously with
Economy operation.
• The Powerful operation overrides the following operations. If
the following operations are set, they will start after the Powerful
operation
fi
nishes.
- Outdoor Unit Low Noise operation
- Energy Saving program
• If the wired remote controller (optional) is connected, this function is
restricted.
8.2. Outdoor Unit Low Noise operation
The Outdoor Unit Low Noise operation lowers noise from the outdoor
unit. During this operation, the rotation number of the compressor
decreases and the outdoor unit fan rotates slowly.
NOTES:
In multi connection, this function cannot be used.
)
Press
to activate/deactivate the Outdoor Unit Low
Noise operation.
While the Outdoor Unit Low Noise operation is activated,
on the remote controller is displayed.
The setting is preserved even if the air conditioner is turned off.
Examples of Weekly timer
Example 1
7:00
9:00
11:00
17:00
23:00
Monday
to
Friday
Program 1 Program 2
Program 3
Program 4
On
Off
On
Off
26 °C
28 °C
Wake up Leave for
work
Come back
home
Go to
sleep
Saturday
(No timer settings)
Sunday
Program 1
Program 2
Program 3
Program 4
Off
Off
Off
Off
(On)
(On)
(On)
(On)
Example 2: You can specify temperature settings using the On timer in
the Weekly timer.
7:00
9:00
17:00
23:00
Program 1
Program 2
Program 3
Program 4
On
On
On
On
28 °C
26 °C
27 °C
28 °C
6.2. On timer or Off timer
1.
Select On timer or Off timer in step 2 of “Timer setting
procedure”.
2.
Press
(
)
to set on time or off time.
Pressing the button: The time will change by +5/-5 minutes.
Pressing down the button: The time will change by +10/-10 minutes.
• To deactivate the On/Off timer, press
while
is
shown on the remote controller display.
The indicator will disappear.
6.3. Program timer
1.
Set On timer and Off timer. (Refer to “6.2. On timer or Off
timer”).
2.
Select Program timer in step 2 of “Timer setting procedure”.
The timer whose setting time is closer to the current time works
fi
rst.
The order of the timer operation is displayed as follows:
Timer
Indicator on the remote controller display
On
→
Off timer
Off
→
On timer
NOTES:
You can set the Program timer only within a span of 24 hours.
6.4. Sleep timer
1.
Select Sleep timer in step 2 of “Timer setting procedure”.
2.
Press
(
)
to set the time until the operation
stops.
Each time you press the button, the time changes as follows:
9H
00M
7H
00M
5H
00M
3H
00M
2H
00M
1H
00M
0H
30M
hours
(30 min.)
• To deactivate the Sleep timer, press
while
is shown
on the remote controller display.
The indicator will disappear.
During the Sleep timer operation, the setting temperature changes as
the following
fi
gure.
In Heating mode
Set
temperature
Set time
1 hour
Set time
1 hour
1.5 hour
30 min.
1 °C 2 °C 3 °C 4 °C
2 °C
1 °C
In Cooling or Dry mode
After the set time has elapsed, the air conditioner operation turns off.
00_9378532090_OM.indb 7
00_9378532090_OM.indb 7
2020/8/31 16:43:49
2020/8/31 16:43:49