En-6
6.1. Weekly timer
Setting details
1.
Select Weekly timer in step 2 of “Timer setting procedure”.
2.
Press
(
)
to select the program number and the
day of the week.
Selected program number (1~4) and the day of the week will blink.
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
3.
Press
.
4.
Press
(
)
to choose the timer operation.
5.
Press
.
* When you chose “Without a timer” in step 4, the setting display will
return to step 1.
6.
Press
(
)
to set on time or off time.
7.
Press
.
* When you chose “Off timer” in step 4, the setting display will return
to step 1.
8.
Press
(
)
to set the temperature.
Temperature setting range
Auto, Cooling, or
Dry mode:
18.0 to 30.0 °C
*Even if you set to 10.0, 16.0-17.5 °C, the air
conditioner will run at 18.0 °C.
Heating mode:
10.0 or 16.0 to 30.0 °C
9.
Press
.
The setting display will return to step 1.
10.
Press
to complete the setting.
Be close to the indoor unit.
NOTES:
[
] indicator on the indoor unit will not turn on even if
the setting is complete.
• If you want to return the previous step, press
.
• To check the schedule, use
(
)
to browse the Weekly
timer settings in step 1.
To
fi
nish checking, press
.
• To deactivate the Weekly timer, press
while
is
shown on the remote controller display.
The indicator will disappear.
NOTES:
• The operation modes will be the same as the mode at the last time
operation was stopped, so Cooling
→
Heating
→
Cooling
→
Heating
type of operations cannot be set automatically.
• If you set the On timer and Off timer on the same time, the On timer
will work.
• If two On timers are set on the same time, the air conditioner will run
in the order of the program number.
• You cannot the Weekly timer and the other timers simultaneously.
If you use the On/Off timer, the Program timer, or the Sleep timer
while the Weekly timer is activated, the Weekly timer will be
deactivated.
In such a case, activate the Weekly timer after the other timer
fi
nishes.
• If the wired remote controller (optional) is connected, this function is
restricted.
Day of the week
Program number
(Without a timer)
(On timer)
(Off timer)
6. TIMER OPERATIONS
NOTES:
When [
] indicator on the indoor unit blinks, set the clock
and timer again. This blinking shows that the internal clock go
wrong due to an interruption of the power supply. (Refer to
page 10.)
Timer setting procedure
Before setting the timer, please adjust the clock. (Refer to “remote
controller preparation”).
1.
Press
.
on the remote controller display will blink.
2.
Press
(
)
to choose timer operation.
The timer operation will change as follows:
[
]
[
]
[
]
Weekly timer
Enables you to set operation
schedules up to 4 setting for each
day of the week.
On timer
Starts the operation at your desired
time.
Off timer
Stops the operation at your desired
time.
Program timer
Operates as the combination of the
On timer and Off timer.
Sleep timer
Supports your comfortable sleep
by moderating the air conditioner
operation gradually.
3.
Press
.
4.
Set each timer operation.
For details, refer to the following instructions of each timer setting.
5.
Press
to complete the timer setting.
Be close to the indoor unit.
• To cancel the timer setting during the procedure, press
again.
• How to set to blow out air from the upper and lower air outlets.
Air Outlet Selection switch
Upper air
fl
ow
Upper and lower air
fl
ow
NOTES:
• Set the air outlet selection switch to the end. Otherwise, air outlet
cannot be selected as intended.
Description of operation
Operation Mode
Air
fl
ow
Conditions
Cooling
Upper and lower
air
fl
ow
Room temperature and set
temperature are different.
Upper air
fl
ow
Room temperature is close
to set temperature, or the air
conditioner has operated for
1 hour.
Dry
Upper and lower
air
fl
ow
-
Heating
Upper and lower
air
fl
ow
Air
fl
ow temperature is high
Upper air
fl
ow
Air
fl
ow temperature is low.
(During defrosting operation,
start of operation, etc.)
00_9378532090_OM.indb 6
00_9378532090_OM.indb 6
2020/8/31 16:43:49
2020/8/31 16:43:49