/BB0/PCI8
PCIE
PCIE3
primary
EMP
/BB1/CMUL/NET0
PCIE
PCIE8
domain01
OCC
/BB1/CMUL/SASHBA
PCIE
PCIE8
domain01
OCC
/BB1/PCI0
PCIE
PCIE9
domain01
EMP
/BB1/PCI3
PCIE
PCIE10
domain01
EMP
/BB1/PCI4
PCIE
PCIE10
domain01
EMP
/BB1/PCI7
PCIE
PCIE11
domain01
EMP
/BB1/PCI8
PCIE
PCIE11
domain01
EMP
#
ldm
stop
domain01
#
ldm
rm-io
PCIE8
domain01
#
ldm
rm-io
PCIE9
domain01
#
ldm
rm-io
PCIE10
domain01
#
ldm
rm-io
PCIE11
domain01
#
ldm
list-io
NAME
TYPE
BUS
DOMAIN
STATUS
----
----
---
------
------
PCIE0
BUS
PCIE0
primary
IOV
PCIE1
BUS
PCIE1
primary
IOV
PCIE2
BUS
PCIE2
primary
IOV
PCIE3
BUS
PCIE3
primary
IOV
PCIE8
BUS
PCIE8
PCIE9
BUS
PCIE9
PCIE10
BUS
PCIE10
PCIE11
BUS
PCIE11
/BB0/CMUL/NET0
PCIE
PCIE0
primary
OCC
/BB0/CMUL/SASHBA
PCIE
PCIE0
primary
OCC
/BB0/PCI0
PCIE
PCIE1
primary
EMP
/BB0/PCI3
PCIE
PCIE2
primary
EMP
/BB0/PCI4
PCIE
PCIE2
primary
EMP
/BB0/PCI7
PCIE
PCIE3
primary
EMP
/BB0/PCI8
PCIE
PCIE3
primary
EMP
/BB1/CMUL/NET0
PCIE
PCIE8
/BB1/CMUL/SASHBA
PCIE
PCIE8
/BB1/PCI0
PCIE
PCIE9
/BB1/PCI3
PCIE
PCIE10
/BB1/PCI4
PCIE
PCIE10
/BB1/PCI7
PCIE
PCIE11
10.
Delete
all
the
I/O
devices
from
the
domain
to
which
the
I/O
devices
of
the
system
board
to
be
deleted
are
assigned.
In
the
following
example,
domain01
is
stopped
and
the
PCIe
root
complexes
that
are
owned
by
domain01
and
related
to
the
system
board
to
be
deleted
are
released.
11.
Execute
the
ldm
list-io
command
again
to
check
the
usage
status
of
the
I/O
devices.
The
following
example
shows
that
the
values
displayed
under
[DOMAIN]
for
PCIE8,
PCIE9,
PCIE10,
and
PCIE11,
which
were
used
by
domain01,
are
deleted
and
the
I/O
devices
are
released.
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service
Manual
・
February
2014
60
Содержание SPARC M10-4
Страница 20: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 xx ...
Страница 34: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 10 ...
Страница 49: ...A Figure 2 12 Location of system locator SPARC M10 4 M10 4S Chapter 2 Understanding the System Components 25 ...
Страница 56: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 32 ...
Страница 94: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 70 ...
Страница 110: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 86 ...
Страница 212: ...4 Close the rack door Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 188 ...
Страница 246: ...4 Close the rack door Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 222 ...
Страница 264: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 240 ...
Страница 290: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 266 ...
Страница 306: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 282 ...
Страница 328: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 304 ...
Страница 338: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 314 ...
Страница 382: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 358 ...
Страница 394: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 370 ...
Страница 416: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 392 ...
Страница 440: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 416 ...
Страница 459: ...Figure 28 22 Removing the cable cable PWR Chapter 28 Maintaining the Cable Kit of the Crossbar Box 435 ...
Страница 465: ...Figure 28 28 Securing the cable cable PWR Chapter 28 Maintaining the Cable Kit of the Crossbar Box 441 ...
Страница 468: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 444 ...
Страница 480: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 456 ...