SPARC Enterprise T5440 Server Service Manual • July 2009
■
“POST Fault Management Overview” on page 19
■
“POST Fault Management Flowchart” on page 20
■
SPARC Enterprise T5440 Server Administration Guide
Identifying Faults Detected by PSH
When a PSH fault is detected, a Solaris console message similar to
Console Message Showing Fault Detected by PSH on page 44
is displayed.
Faults detected by the Solaris PSH facility are also reported through service processor
alerts.
Note –
You can configure ILOM to generate SNMP traps or e-mail alerts when a
fault is detected by Solaris PSH. You can also configure the ALOM CMT
compatibility shell to display Solaris PSH alerts. See the
Integrated Lights Out Manager
3.0 Concepts Guide
.
CODE EXAMPLE: ALOM CMT Alert of PSH Diagnosed Fault on page 44
depicts an
ALOM CMT alert of the same fault reported by Solaris PSH in
Console Message Showing Fault Detected by PSH on page 44
The ILOM
show faulty
command provides summary information about the fault.
See
for more
information about the
show faulty
command.
CODE EXAMPLE:
Console Message Showing Fault Detected by PSH
SUNW-MSG-ID: SUN4V-8000-DX, TYPE: Fault, VER: 1, SEVERITY: Minor
EVENT-TIME: Wed Sep 14 10:09:46 EDT 2005
PLATFORM: SUNW,
system_name
, CSN: -, HOSTNAME: wgs48-37
SOURCE: cpumem-diagnosis, REV: 1.5
EVENT-ID: f92e9fbe-735e-c218-cf87-9e1720a28004
DESC: The number of errors associated with this memory module has exceeded
acceptable levels. Refer to http://sun.com/msg/SUN4V-8000-DX for more
information.
AUTO-RESPONSE: Pages of memory associated with this memory module are being
removed from service as errors are reported.
IMPACT: Total system memory capacity will be reduced as pages are retired.
REC-ACTION: Schedule a repair procedure to replace the affected memory module.
Use fmdump -v -u <EVENT_ID> to identify the module.
CODE EXAMPLE:
ALOM CMT Alert of PSH Diagnosed Fault
SC Alert: Host detected fault, MSGID: SUN4V-8000-DX
Содержание SPARC Enterprise T5440 Server
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 14: ...xii SPARC Enterprise T5440 Server Service Manual July 2009 Field Replaceable Units 176 Index 179 ...
Страница 26: ...xxiv SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 84: ...58 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 180: ...154 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 192: ...166 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 198: ...172 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 212: ...186 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 213: ......
Страница 214: ......