Setting Sequencer
The sequencer operates in the following order:
1) The sequencer starts after the program execution.
2) Depending on the setting at each level (1 & 2), branching to the next level is performed
when the condition is met.
3) The sequencer is restarted when the restart condition is met.
4) The sequencer is terminated and a break occurs when the level 3 condition is met.
■
Setting Sequencer
The sequencer operates in the following order: The event can be set at each level and as a restart condition.
1. The sequencer starts after the program execution.
2. Depending on the setting at each level (1 & 2), branching to the next level is performed when the
condition is met.
3. The sequencer is restarted when the restart condition is met.
4. The sequencer is terminated and a break occurs when the level 3 condition is met.
Use the following commands to set the sequencer.
SET SEQUENCE: Setting an event for the sequencer
[Example]
>SET SEQUENCE 1, 3, 2, r=4
Set event 1, 3, 2 to level 1, 2, 3 respectively, and event 4 for the restart condition.