CHAPTER 2 DEPENDENCE FUNCTIONS
■
Setting Events
The emulator can monitor the MCU bus operation, and generate a trigger for a sequencer at a specified
condition. This function is called an event.
In the event, code (/CODE) and data access (/READ/WRITE) can be specified.
Up to eight events can be set. However, since hardware is shared with trace triggers, the actual numbers is
calculated as follows.
Current maximum constant of events
= 8 - (current number of trace trigger se current number of data monitoring break settings)
Table 2.3-5 shows the conditions that can be set for events.
Note:
In instruction execution (/CODE), an event trigger is generated only when an instruction is executed.
This cannot be specified concurrently with other status (/READ or /WRITE).
Use the following commands to set an event.
SET EVENT :
Sets an event
SHOW EVENT :
Displays the status of event setting
CANCEL EVENT :
Deletes an event
[Example]
>SET EVENT/CODE
func1
>SET EVENT/WRITE data[2],!d=h'10
>SET EVENT/READ/WRITE 102
Table 2.3-5 Conditions for Event and Trace Trigger
Condition
Description
Address
Memory location (address bit masking disabled)
Data
16-bit data (data bit masking enabled)
Access size
Byte, word
Status
Select from code, data read or data write
Содержание SOFTUNE F2 MC-16
Страница 2: ......
Страница 3: ...FUJITSU SEMICONDUCTOR LIMITED F2 MC 16 FAMILY SOFTUNETM Workbench USER S MANUAL ...
Страница 4: ......
Страница 8: ...iv ...
Страница 14: ...x ...
Страница 84: ...70 CHAPTER 2 DEPENDENCE FUNCTIONS Note The F2 MC 16 16H only allows this setup in the debugging mode ...
Страница 342: ...328 CHAPTER 2 DEPENDENCE FUNCTIONS ...
Страница 343: ...329 INDEX INDEX The index follows on the next page This is listed in alphabetic order ...
Страница 352: ...338 INDEX ...
Страница 354: ......