
506
Upgrade and Maintenance Manual
TX2550 M4
Appendix A
18.2.2.3 Indicators on the hot-plug HDD/SSD module
Figure 366: Indicators on the hot-plug HDD/SSD module
Pos.
Label
Indicator
Status
Description
1
Access
indicator
off
The HDD/SSD is inactive.
green on
The HDD/SSD being accessed
2
Error
indicator
off
No HDD/SSD error detected.
orange on
An HDD/SSD error has been
detected.
Possible causes:
– The drive is defective and needs
replacing.
– A RAID rebuild process has
failed.
– The HDD/SSD module has not
been inserted correctly.
orange
flashing
slowly
HDD/SSD RAID rebuild is in
progress. Data is being restored
after replacing a drive that has been
combined into a RAID array.
!
Содержание PRIMERGY TX2550 M4
Страница 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Страница 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Страница 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Страница 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Страница 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Страница 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Страница 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Страница 491: ...TX2550 M4 Upgrade and Maintenance Manual 491 18 Appendix A 18 1 Mechanical overview 18 1 1 Server front ...
Страница 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Страница 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Страница 519: ...FUJITSU Server PRIMERGY TX2550 M4 System Cabling Overview System Cabling Overview English Cable plan for April 2018 ...
Страница 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...