454
Upgrade and Maintenance Manual
TX2550 M4
System board and components
Ê
Place the removed and the new system board on an antistatic surface.
Ê
Remove the TPM, see section
"Removing the TPM" on page 421
14.7.1.3 Installing the new system board
I
For the cable plan see chapter
Ê
Check the settings on the new system board (see section
).
Ê
Insert the system board by holding it at a slight angle. Insert the connectors
into the I/O panel (see figure
).
Ê
Lower the system board carefully into the chassis.
Ê
Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion (orange circles in figure
show the centering bolts).
Ê
Fasten the system board with the 13 screws (see figure
Ê
For Japan / APAC / North America only:
Replace the CMOS battery installed on the new system board with a new
CMOS battery (see section
), because
charging of CMOS battery might be reduced during stocked in warehouse.
Ê
Remove the heat sink with the CPU from the defective system board, see
section
"Removing the heat sink" on page 366
.
Ê
Remove the protective plastic cover from the CPU socket of the new system
board and fit it onto the socket of the defective system board which will be
sent back to spares.
I
Returned system boards without this cover probably have to be
scrapped.
Ê
Install the heat sink with the CPU on the new system board, see section
"Installing the CPU and heat sink" on page 358
Ê
Connect all cables to the system board:
– Front panel cable
– Front USB cable
– Power cable(s) for HDD backplane(s)
– SATA cable(s) for HDD backplane(s)
Содержание PRIMERGY TX2550 M4
Страница 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Страница 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Страница 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Страница 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Страница 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Страница 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Страница 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Страница 491: ...TX2550 M4 Upgrade and Maintenance Manual 491 18 Appendix A 18 1 Mechanical overview 18 1 1 Server front ...
Страница 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Страница 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Страница 519: ...FUJITSU Server PRIMERGY TX2550 M4 System Cabling Overview System Cabling Overview English Cable plan for April 2018 ...
Страница 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...