422
Upgrade and Maintenance Manual
TX2550 M4
System board and components
Ê
To turn off BitLocker and decrypt the volume, click
Turn Off BitLocker
, and
then click
Decrypt the volume
.
I
Decrypting the volume may be time-consuming. By decrypting the
volume, all of the information stored on that computer is decrypted.
For more information on how to disable BitLocker drive encryption,
see the Microsoft Knowledge Base.
For more information, see the Fujitsu web pages.
Ê
Disable TPM in the system board BIOS. Proceed as follows:
Ê
Switch on or restart your server.
Ê
As soon as the startup screen appears, press the
[F2]
function key to
enter the BIOS.
Ê
Select the
Advanced
menu.
Ê
Select the
Trusted Computing
submenu.
Ê
Set the
TPM Support
and
TPM State
settings to
Disabled
.
Ê
Save your changes and exit the BIOS.
I
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Ê
"Suspending BitLocker functionality" on page 105
Ê
"Shutting down the server" on page 52
Ê
"Disconnecting the power cord" on page 53
Ê
"Getting access to the component" on page 54
Ê
"Removing the system air duct" on page 67
Ê
"Removing the PCI air duct" on page 86
Ê
If applicable,
"Removing the riser module" on page 84
Ê
"Removing the crossbar" on page 88
Ê
Remove the fan bridge, see section
"Handling fan bridges" on page 90
14.3.2.2 Removing the TPM
Ê
Remove the system board, see section
Содержание PRIMERGY TX2550 M4
Страница 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Страница 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Страница 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Страница 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Страница 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Страница 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Страница 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Страница 491: ...TX2550 M4 Upgrade and Maintenance Manual 491 18 Appendix A 18 1 Mechanical overview 18 1 1 Server front ...
Страница 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Страница 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Страница 519: ...FUJITSU Server PRIMERGY TX2550 M4 System Cabling Overview System Cabling Overview English Cable plan for April 2018 ...
Страница 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...