After replacing a network controller or the system board, switch on and boot
the server, see
"Switching on the server" on page 81
The hardware configuration tool for Red Hat Linux, will launch at boot and
detect the new and/or changed hardware on your system.
▶
For the changes to take effect, you need to reboot the network by entering
the following command:
# service network restart
If the system board or network controller offers multiple LAN ports, it
is necessary to update the remaining
ifcfg-eth<x>
definition files
accordingly.
▶
Update the NIC configuration file to reflect the new card sequence and MAC
address.
5.3.14
Resuming BitLocker functionality
If BitLocker Drive Encryption has been suspended for maintenance purposes
(see
"Suspending BitLocker functionality" on page 99
to complete the service task.
▶
If applicable, ask the system administrator to enter the recovery key in order
to boot the OS.
If BitLocker Drive Encryption has been suspended prior to replacing
components you won't be asked for a recovery key when rebooting
the server after the maintenance task. However, if BitLocker
functionality has not been suspended, Windows will enter recovery
mode and ask you to input recovery key for further booting.
▶
Ask the system administrator to enable the previously suspended BitLocker
protection on the system volume, using the
BitLocker Drive Encryption
control panel item:
▶
Click
Start
-
Control Panel
-
System and Security
-
BitLocker Drive
Encryption
to open the BitLocker Drive Encryption.
▶
Select the system volume, and click
Resume Protection
.
Basic software procedures
TX1330 M4
Upgrade and Maintenance Manual
121
Содержание PRIMERGY TX1330 M4
Страница 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Страница 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 412: ... Resuming BitLocker functionality on page 121 Front panel 412 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 478: ...Figure 315 Removing the intrusion switch holder A Cabling 478 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 520: ...FUJITSU Server PRIMERGY TX1330 M4 Reference Manual Reference Manual English Cable Plan for April 2022 ...
Страница 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...