Using Infrastructure Manager
The status of server (node) which failed CPU is installed becomes error.
When replacing the CPU, the status will be updated after getting information
manually or automatically updated daily.
Proceed as follows to get node information with Infrastructure Manager:
▶
Start up the GUI of the Infrastructure Manager and login.
▶
Display the node list from menu (
manage
>
node
).
▶
Select the target node and display the detail screen.
▶
Execute getting node information from action menu.
5.3.8
Enabling the boot watchdog
If the boot watchdog has been disabled for firmware upgrade purposes (see
"Disabling the boot watchdog" on page 100
), it has to be re-enabled to
complete the maintenance task.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web interface.
Enabling the boot watchdog in the BIOS
▶
Enter the BIOS.
▶
Select the
Server Mgmt
menu.
▶
Under
Boot Watchdog
set the
Action
setting to
Reset
.
▶
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Enabling the boot watchdog using the iRMC web interface
▶
Log in to the ServerView iRMC web interface.
▶
Select the
Settings
menu.
Basic software procedures
114
Upgrade and Maintenance Manual
TX1330 M4
Содержание PRIMERGY TX1330 M4
Страница 18: ...Content Upgrade and Maintenance Manual TX1330 M4 ...
Страница 276: ...Hard disk drive HDD solid state disk SSD 276 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 286: ...Fans 286 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 330: ...Expansion cards and backup units 330 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 340: ...Main memory 340 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 402: ...Accessible drives 402 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 412: ... Resuming BitLocker functionality on page 121 Front panel 412 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 474: ...Converting a floorstand model to a rack model 474 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 478: ...Figure 315 Removing the intrusion switch holder A Cabling 478 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 486: ...Cabling 486 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 518: ...Appendix A 518 Upgrade and Maintenance Manual TX1330 M4 ...
Страница 520: ...FUJITSU Server PRIMERGY TX1330 M4 Reference Manual Reference Manual English Cable Plan for April 2022 ...
Страница 560: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...