38
Operating Manual
TX1330 M2
Important information
Modules with Electrostatic-Sensitive Devices
Modules with electrostatic-sensitive devices are identified by the following
sticker:
Figure 1: ESD label
When you handle components fitted with ESDs, you must always observe the
following points:
●
Switch off the system and remove the power plugs from the power outlets
before installing or removing components with ESDs.
●
You must always discharge static build-up (e.g. by touching a grounded
object) before working with such components.
●
Any devices or tools that are used must be free of electrostatic charge.
●
Wear a suitable grounding cable that connects you to the external chassis
of the system unit.
●
Always hold components with ESDs at the edges or at the points marked
green (touch points).
●
Do not touch any connectors or conduction paths on an ESD.
●
Place all the components on a pad which is free of electrostatic charge.
I
For a detailed description of how to handle ESD components, see the
relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).
Information for ensuring electromagnetic compatibility
All data and signal cables must have sufficient shielding. The use of cable type
S/FTP Cat5 or higher is recommended.
Use of unshielded or badly shielded cables may lead to increased emission of
interference and/or reduced fault-tolerance of the device.
Содержание PRIMERGY TX1330 M2
Страница 1: ...Operating Manual English FUJITSU Server PRIMERGY TX1330 M2 Operating Manual Edition November 2015 ...
Страница 8: ...Operating Manual TX1330 M2 Contents ...
Страница 12: ...12 Operating Manual TX1330 M2 Introduction ...
Страница 56: ...56 Operating Manual TX1330 M2 Hardware installation ...
Страница 78: ...78 Operating Manual TX1330 M2 Starting up and operation ...
Страница 80: ...80 Operating Manual TX1330 M2 Property and data protection ...