background image

88

Operating Manual

 TX1320 M3

Troubleshooting and tips

8.2

Server switches itself off

Server Management has detected an error

Ê

Check the error list of System Event Log in ServerView Operations Manager 
or in the iRMC web interface, and attempt to eliminate the error.

8.3

Screen remains blank

Monitor is switched off

Ê

Switch on your monitor.

Screen has gone blank

Ê

Press any key on the keyboard.

or

Ê

Deactivate screen saver. Enter the appropriate password.

Brightness control is set to dark

Ê

Set the brightness control on the monitor to light. For detailed information, 
refer to the operating manual supplied with your monitor.

Power cable or monitor cable not connected

Ê

Switch off the monitor and the server.

Ê

Check whether the power cable is properly connected to the monitor and to 
the grounded power outlet.

Ê

Check whether the monitor cable is properly connected to the server and 
monitor (if it is plugged in with a connector). If a separate graphics card is 
installed in the server, then the monitor cable must be connected to the 
graphics card.

Ê

Switch on the monitor and the server.

Содержание PRIMERGY TX1320 M3

Страница 1: ...rver PRIMERGY TX1320 M3 Operating Manual March 2017 Questo manuale d istruzione è fornito da trovaprezzi it Scopri tutte le offerte per Fujitsu PRIMERGY TX1320 M3 VFY T1323SX120IT o cerca il tuo prodotto tra le migliori offerte di Server ...

Страница 2: ...kumentation mbH www cognitas de Copyright 2017 FUJITSU LIMITED All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights arising f...

Страница 3: ...se components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The custome...

Страница 4: ...d by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferred to non residents...

Страница 5: ...tion 33 4 1 Safety instructions 33 4 2 ENERGY STAR 42 4 3 CE conformity 42 4 4 FCC Class A Compliance Statement 43 4 5 Environmental protection 44 5 Hardware installation 47 5 1 Unpacking the server 48 5 2 Setting up the server 49 5 2 1 Positioning the server vertically 50 5 2 2 Positioning the server horizontally 53 5 3 Connecting devices to the server 54 5 4 Connecting the server to the mains 56...

Страница 6: ...ts FJBU 75 6 4 ID card 76 6 5 Switching the server on and off 77 6 6 Configuring the server 80 6 6 1 Configuring the onboard SATA controller 80 6 6 2 Configuring the SAS SATA RAID controller 81 6 6 3 Configuring the server and installing the operating system with the ServerView Installation Manager 82 6 6 4 Configuring the server and installing the operating system without the ServerView Installat...

Страница 7: ...n monitor screen 89 8 5 No screen display or display drifts 89 8 6 No mouse pointer displayed on screen 89 8 7 Incorrect date and time 90 8 8 Drives reported as dead when starting system 90 8 9 Added drive reported as defective 90 8 10 Error message on screen 91 ...

Страница 8: ...Operating Manual TX1320 M3 Contents ...

Страница 9: ...ager for server management Prefailure Detection and Analysing PDA and Automatic Server Reconfiguration and Restart ASR R Security functions in the BIOS setup protect the data on the server against manipulation Additional security is provided by the lockable drive cover 1 1 Concept and target groups for this manual This operating manual describes how to install set up and operate your server This o...

Страница 10: ... D3373 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M3 Reference Manual I All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at http manuals ts fujitsu com For Japan http www fujitsu com jp products computing servers primergy manual The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at ftp ftp t...

Страница 11: ...nu items Quotation marks indicate names of chapters and terms that are being emphasized Ê describes activities that must be performed in the order shown V CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates additional information notes and tips ...

Страница 12: ...12 Operating Manual TX1320 M3 Introduction ...

Страница 13: ...mponents yourself in the event of an error Hot plug HDD SSD modules Hot plug PSUs Memory modules System fans Expansion cards For information on replacing these components see the FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises In addition CSS errors are dis...

Страница 14: ...rm Module TPM A Trusted Platform Module TPM for safer storage of keys can be implemented as an option This module enables programs from third party manufacturers to store key information e g drive encryption using Windows Bitlocker Drive Encryption The TPM is activated via the BIOS system for more information refer to the D3373 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M3 Reference Man...

Страница 15: ...e cage Each HDD module can accommodate an SAS SATA HDD with a 2 5 inch format The modules are connected to the SAS SATA backplane wirelessly This allows HDD modules to be plugged in or pulled out easily If the server has a corresponding RAID configuration defective HDD modules can also be replaced during operation Onboard SATA controller A SATA controller is integrated on the system board up to fo...

Страница 16: ...iguring the SAS SATA RAID controller on page 81 Further information on SAS SATA RAID controllers is provided in the Modular RAID Controller Installation Guide on the Fujitsu manuals server under x86 Servers Expansion Cards Storage Adapters Further information on other SAS SATA RAID controllers e g for operating external SAS SATA HDDs or tape drives is available on the Fujitsu manuals server under ...

Страница 17: ...re is not available in Red Hat Enterprise Linux environment Please use the IPMI function at Linux environment Advanced Thermal Design The Advanced Thermal Design option allows you to operate the system with a wider temperature range of 5 C to 40 C depending on your system and configuration V CAUTION In a system that is configured with Advanced Thermal Design only certain components which support t...

Страница 18: ...matic Server Reconfiguration and Restart restarts the system in the event of an error and automatically hides the defective system components The PDA Prefailure Detection and Analysis technology from Fujitsu analyzes and monitors all components that are critical for system reliability A RAID controller supports different RAID levels and increase the availability and data security of the system The...

Страница 19: ...ng Browser access via iRMC S4 s own Web server Secure communication SSH SSL Power Management for the managed server depending on its system status Power Consumption Management Connecting virtual drives as remote storage Text based and graphic console bypass Advanced Video Redirection Remote Storage Command Line Interface CLI Simple interactive or script based iRMC S4configuration Customer Self Ser...

Страница 20: ...GY servers in the network via a central console The ServerView Operations Manager supports the following functions Round the clock monitoring regardless of server status High performance graphical console bypass AVR protected by HTTPS SSL 128 bit Remote storage via USB Remote power on Intrusion detection in the floorstand model Temperature monitoring of the CPU and the surrounding area Detailed st...

Страница 21: ... and immediate recognition In order to prevent the components from being damaged by incorrect handling when they are being installed and removed the areas of all components that can be touched without damaging them are also marked green PRIMERGY diagnostic LEDs fitted on the system board indicate which component memory module CPU fan or expansion card is not functioning properly The Flash EPROM pr...

Страница 22: ...leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution The administrator can access all system information and information from the sensors such as fan speeds or voltages via the iRMC S4 s Web interface see section iRMC S4 with integrated management LAN connector on page 19 You can also start the text based or graphic console by...

Страница 23: ...s Configuration System board type D3373 Chipset Intel E3 1200V6 and Intel C236 CPU quantity and type 1x Intel Xeon E3 1200 v6 quad core Pentium Core i3 Memory slots 4 Memory slot type UDIMM DDR4 Memory capacity min max 4 GB 64 GB Memory protection ECC Memory notes Dual channel support For dual channel performance a minimum of 2 memory modules has to be ordered Capacity per channel has to be the sa...

Страница 24: ...r Host Bus Adapter with Integrated RAID IR RAID levels 0 and 1 are supported for internal HDD configurations Modular RAID 0 1 controller with MegaRAID functionality integrated MegaRAID RAID levels 0 1 10 5 and 50 are supported for internal HDD configurations Modular RAID 5 6 controller with MegaRAID functionality MegaRAID RAID levels 0 1 10 5 50 6 and 60 are supported for internal HDD configuratio...

Страница 25: ...1x PCI Express occupied by modular RAID controller Hard disk bay configuration 8x 2 5 inch hot plug SAS SATA or 2x 3 5 inch non hot plug SATA Accessible drive bays 1x 3 5 1 6 inch for backup devices Ultra Slim ODD Notes accessible drives all possible options described in relevant system configurator Operating buttons Reset button NMI button ID button On Off button Status LEDs ID indicator blue CSS...

Страница 26: ...ition W x D x H 193 mm x 438 mm x 360 mm including feet Horizontal operating position W x D x H 340 mm x 400 mm x 101 mm Weight up to 11 kg Weight notes Weight may vary depending on actual configuration Environment class 3K2 Environment class 2K2 EN60721 IEC 721 Part 3 3 EN60721 IEC 721 Part 3 2 Temperature Operation 3K2 5 C 40 C with ATD 10 C 35 C without ATD Transport 2K2 25 C 60 C Humidity 10 8...

Страница 27: ...9 dB A standby 33 dB A operation Declared noise emission according to ISO 9296 Standby Operating ISO 7779 ETSI 300 753 Class 3 1 LpAm at bystander position A weighted sound power level LWAd Standby fan control standard 20 dB A 3 3 B Standby fan control performance active with INTEL LAN X540 T2 10 GB 30 dB A 4 5 B Operation OLTIS 100 depending on the configuration 22 dB A 3 5 B Standby fan control ...

Страница 28: ...nge 100 240 V Rated frequency range 50 60 Hz Rated current 5 0 A 2 5 A 250 W AC outlet included 3 A 1 5 A 450 W Main power fuse 16 A Protection class I Battery unit configuration 1x hot plug power supply and an FJBU inserted in slot 2 Max output 280 W Backup duration Max 2 seconds 380W 4 minutes 280W with FJBU M2 Charge duration 4 hours to 90 5 hours to 100 Battery spec Nickel Metal Hydrite batter...

Страница 29: ... 1 2ed EN 62479 Ergonomics EK1 ITB 2003 2007 USA Canada CSA C22 2 No 60950 1 07 2ed UL 60950 1 2ed Taiwan CNS 14336 China GB 4943 Electromagnetic compatibility International CISPR 22 Europe EN 55032 Class A EN 55024 EN 61000 3 2 EN 61000 3 3 ETSI 300386 USA Canada 47CFR part 15 Class A ICES 003 Taiwan CNS 13438 Class A China GB 9245 GB 17625 Japan VCCI Class A JEITA Korea KN 32 KN 35 CE marking to...

Страница 30: ...30 Operating Manual TX1320 M3 Functional overview ...

Страница 31: ...ery note see section Unpacking the server on page 48 Ê Make sure that all necessary manuals see Documentation overview on page 10 are available print out the PDF files if required Ê Set up the server see section Setting up the server on page 49 Ê Components that have been ordered additionally may be delivered loose with the server Install these in the server as described in the supplied documentat...

Страница 32: ...erView Suite Server Installation and Deployment Configuration information can also be found in section Configuring the server and installing the operating system with the ServerView Installation Manager on page 82 Local configuration and installation with or without the ServerView Installation Manager see section Configuring the server and installing the operating system with the ServerView Instal...

Страница 33: ...ur sales outlet or our customer service team The actions described in this manual shall be performed by technical specialists A technical specialist is a person who is trained to install the server including hardware and software Repairs to the server that do not relate to CSS failures shall be performed by service personnel Please note that unauthorized interference with the server will void the ...

Страница 34: ... C or 45 C If the server is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for type A connectors The server automatically adjusts itself to a mains voltage see the type label of your server Ensure that the local mains volta...

Страница 35: ...transmission lines during a storm risk of lightning hazard Make sure that no objects e g jewelry paperclips etc or liquids can get inside the server risk of electric shock short circuit In emergencies e g damaged casing controls or cables penetration of liquids or foreign bodies contact the server administrator or your customer service team Only disconnect the server from the mains power supply if...

Страница 36: ... void the warranty and exempt the manufacturer from all liability The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity To ensure reliable protection you must wear an earthing band on your wrist when working with this type of module and connect it to an unpainted conducting metal part of the server Do not touch the circuitry on boards or sol...

Страница 37: ...e followed V CAUTION Only use CDs DVDs BDs that are in perfect condition in order to prevent data loss equipment damage and injury Check each CD DVD BD for damage cracks breakages etc before inserting it in the drive Note that any additional labels applied may change the mechanical properties of a CD DVD BD and cause imbalance and vibrations Damaged and imbalanced CDs DVDs BDs can break at high dr...

Страница 38: ...ter record sprays antistatic agents or silicone impregnated cloth Be careful not to damage the CD DVD BD surface Keep the CDs DVDs BDs away from heat sources Do not bend or place heavy objects on CDs DVDs BDs Do not write with ballpoint pen or pencil on the label printed side Do not attach stickers or similar to the label side Doing so may cause rotational eccentricity and abnormal vibrations When...

Страница 39: ...ser class 1 V CAUTION The optical disk drive contains a light emitting diode LED which under certain circumstances produces a laser beam stronger than laser class 1 Looking directly at this beam is dangerous Never remove parts of the optical disk drive casing Modules with Electrostatic Sensitive Devices ESD modules Modules with electrostatic sensitive devices are identified by the following sticke...

Страница 40: ...ge I For a detailed description of how to handle ESD modules see the relevant European or international standards EN 61340 5 1 ANSI ESD S20 20 Transporting the server V CAUTION Only transport the server in its original packaging or in packaging that protects it from impacts and jolts In Japan and APAC transporting the server in its original packaging does not apply Do not unpack the server until i...

Страница 41: ...e safety information of the rack and the warning label If the server rack is intended for permanent connection to the mains only an authorized specialist electrician is allowed to work Please follow the regulation of each country If the server is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector the power supply s fuse protection...

Страница 42: ...g out measurement values including those relating to current energy consumption and air temperatures Either the Performance Monitor or the Task Manager can be used to read out CPU utilization levels The system complies with the requirements of European Regulations Find the CE declaration on certificate portal https sp ts fujitsu com sites certificates default aspx To open the CE declaration applic...

Страница 43: ...ence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between equipment and the receiver Connect...

Страница 44: ...ched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information does not apply in Japan and APAC Do not throw away the packaging You may need it later for transporting the server If possible the equipment should only be transported in its original packaging Information on handling consumables Please di...

Страница 45: ...ables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or at http ts fujitsu com recycling The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2012 19 EU on waste electrical and electronic equipment WEEE This directive sets the framework for returning and recycling used equipment and i...

Страница 46: ...46 Operating Manual TX1320 M3 Important information ...

Страница 47: ... and heat Make sure that the server is acclimatized for the time indicated in this table before putting it into operation In the table Acclimatization time the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously outside transport or storage temperature Temperature difference C Minimum acclimati...

Страница 48: ...he server to the place where you want to set it up Ê Unpack all individual parts Keep the original packaging in case you want to transport the server again does not apply to Japan Ê Check the delivery for any damage during transport Ê Check whether the items delivered match the details on the delivery note The product name and serial number of the product can be found on the ID card see section ID...

Страница 49: ...tances for operation and maintenance areas must be adhered to The server must be accessible at the rear for connection to other devices e g memory subsystem The mains plug must be accessible easily and safely There must be a clearance of at least 200 mm in front of and behind the server to ensure adequate ventilation of the system Ê Wire the server Follow the instructions in sections Connecting de...

Страница 50: ...rver is positioned vertically the stabilizers must be attached The stabilizers must be attached in the correct direction see figure 4 on page 52 Clipping the stabilizers together Figure 2 Clipping the stabilizer together Ê Clip the stabilizers together in the direction of the arrow as far as the marking line a a ...

Страница 51: ...e installation Adjusting the width of the stabilizers Figure 3 Adjusting the width of a stabilizer You may have to adjust the width of the stabilizers Ê Press the two locking levers 1 and keep them pressed Ê Pull the stabilizer apart 2 0 0 ...

Страница 52: ...3 Hardware installation Placing the server on the stabilizers Figure 4 Placing the server on stabilizers Ê Place the server on the stabilizers 1 Position the stabilizers between the rubber feet 2 Ê Press the stabilizers together 3 ...

Страница 53: ...nstallation 5 2 2 Positioning the server horizontally V CAUTION If the server is positioned horizontally ensure that the rubber feet are pointing downward Figure 5 Positioning the server horizontally Ê Place the server on its four rubber feet ...

Страница 54: ...connectors for external devices are on the front and rear of the server The additional connectors available on your server depend on the expansion cards installed Two color coded USB connectors are located on the front of the server Figure 6 Connectors on the front 1 2 x USB 3 0 connectors blue ...

Страница 55: ...s that can be connected may require special drivers see the documentation for the connected device Ê Connect the data cables to the server and peripherals 1 Management LAN connector for iRMC S4 server management function 2 Shared LAN connector LAN1 3 Standard LAN connector LAN2 4 2x USB 3 0 connectors blue 5 4x USB 2 0 connectors black 6 Video connector blue 7 Serial connector COM1 turquoise ...

Страница 56: ...d hot plug PSU can be installed optionally to serve as a redundant power supply If one PSU fails the second PSU in the redundant configuration ensures operation can continue uninterrupted V CAUTION The server is automatically set to a mains voltage in the range 100V 240V You may only operate the server if its rated voltage range corresponds to the local mains voltage Ê Connect the power cord to th...

Страница 57: ...cted from the PSU accidentally The cable tie is included in the accessories pack that is delivered together with the server Figure 8 Using cable ties Ê Thread the cable tie through the eye 1 Ê Pull the cable tie tight to secure the power cable The insulated connector cannot now be disconnected from the server accidentally I You can loosen the cable tie by opening the small locking lever 2 0 1 ...

Страница 58: ...secure the power cords in cable clamps to ensure that the insulated connectors cannot be disconnected from the server accidentally Figure 9 Using cable clamps Ê Pull the cable clamp up 1 Ê Thread the power cord through the cable clamp 2 Ê Press the cable clamp down until it engages to secure the cable 3 ...

Страница 59: ...ng cables Ê Turn off all power and equipment switches Ê Disconnect all power plugs from the properly grounded power outlets Ê Connect all cables to the server and peripherals Ê Plug all data communication cables into the utility sockets Ê Plug all power cords into the properly grounded power outlets Disconnecting cables Ê Turn off all power and equipment switches Ê Disconnect all power plugs from ...

Страница 60: ...lectromagnetic compatibility All data and signal cables must have sufficient shielding The use of cable type S FTP Cat5 or higher is recommended Use of unshielded or badly shielded cables may lead to increased emission of interference and or reduced fault tolerance of the device ...

Страница 61: ... drives Opening the drive cover Figure 10 Opening the drive cover Ê Turn the key counterclockwise 1 to unlock the front cover and remove the key Ê Open the drive cover carefully in the direction of the arrow 2 until the ratches of the cover are released and pull it downward to remove it 3 V CAUTION Do not pull too hard to avoid damage to the locking mechanism ...

Страница 62: ...5 I Please note the following when operating with tape drives If the system is programmed to eject the media automatically the accessible drives must not be obstructed The drive cover is replaced and the server locked in the reverse order Figure 11 Removing the drive cover from the HDD cover Ê Carefully pull out on the green release lever 1 and lift off the drive cover 2 ...

Страница 63: ...ating Manual 63 Starting up and operation 6 2 Opening the HDD cover Figure 12 Removing the HDD cover Ê Unlock the server 1 Ê Remove the HDD cover 2 The HDD cover is replaced and the server locked in the reverse order ...

Страница 64: ...ystem Press the reset button with a straightened end of a paper clip V CAUTION Risk of data loss 2 NMI NMI button Used to troubleshoot software and device driver errors Press the NMI button with a straightened end of a paper clip V CAUTION Use this button only if directed to do so by qualified certified maintenance personnel 3 ID ID button Highlights the ID indicator on the front panel and the rea...

Страница 65: ...escription 1 ID ID indicator see also iRMC related status signals on page 67 blue on The server has been highlighted using ServerView Operations Manager iRMC web frontend or the ID button on the front panel for easy identification blue flashing The server has been highlighted for easy identification using the iRMC AVR with disabled local VGA output 2 CSS CSS indicator off No critical event detecte...

Страница 66: ...perature specified range Defective sensor CPU error Error detected by server management software 4 HDD SSD activity indicator green flashing Data access in progress 5 Power on indicator off The server is switched off green on The server has been switched on but Power Cycle Delay settings delay it from turning on for a specified time The server is switched on and operating normally green flashing s...

Страница 67: ...nter standby mode and can be switched on off The server is switched off and not connected to the mains The server is switched on and operating normally ID indicator Global error indicator Description blue flashing off A remote connection has been established Local VGA output has been disabled during the remote session blue flashing orange flashing An emergency flash of the iRMC firmware is in prog...

Страница 68: ... the drives Optical drive activity indicator Figure 15 Indicator on the optical drive I There are also optical drives without activity indicators Pos Indicator Status Description 1 Activity indicator off The optical drive is inactive green on The storage medium is being accessed ...

Страница 69: ...ive green on The HDD SSD being accessed 2 Error indicator off No HDD SSD error detected orange on An HDD SSD error has been detected Possible causes The drive is defective and needs replacing A RAID rebuild process has failed The HDD SSD module has not been inserted correctly orange flashing slowly RAID rebuild is in progress Data is being restored after replacing a drive that has been combined in...

Страница 70: ...ating Manual TX1320 M3 Starting up and operation 6 3 2 Server rear 6 3 2 1 Indicators on the I O panel CSS Global Error and ID indicators Figure 17 Indicator on the I O panel CSS Global Error and ID indicator ...

Страница 71: ...erver has been highlighted using ServerView Operations Manager iRMC web frontend or the ID button on the front panel for easy identification blue flashing The server has been highlighted for easy identification using the iRMC AVR with disabled local VGA output CSS CSS indicator off No critical event detected CSS component orange on Prefailure event detected CSS component orange flashing CSS compon...

Страница 72: ...hing off A remote connection has been established Local VGA output has been disabled during the remote session blue flashing orange flashing An emergency flash of the iRMC firmware is in progress I For further information on the emergency flash of the iRMC firmware refer to the FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual ...

Страница 73: ...nformation in the D3373 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M3 Reference Manual Pos Indicator Status Description 1 LAN link transfer indicator green on A LAN connection has been established off LAN is not connected green flashing LAN data transfer is in progress 2 LAN speed indicator yellow on Data traffic at a transfer rate of 1 Gbit s green on Data traffic at a transfer rate of...

Страница 74: ... status indicator green flashing The server is switched off but mains voltage is present standby mode green on The server is switched on and operating properly orange flashing An overload has been detected The PSU is still running but failure might be imminent orange on An PSU failure has been detected Possible causes Over under voltage Overheating Fan failure ...

Страница 75: ...ndicator Status Description 1 FJBU status indicator green flashing The battery unit is charging green flashing slowly The battery unit is discharging green on The battery unit is fully charged orange flashing A battery unit failure has been detected Possible causes Capacity failure Overheating orange on A general battery failure has occurred ...

Страница 76: ...D card You can pull out the ID card as far as it will go and push it back again The ID card contains various system information such as the product name serial number order number MAC addresses and DNS name For Japan The ID card contains only the product name and the serial number ...

Страница 77: ... refer to Safety Precautions When operating the device outside of this operating environment the server may operate improperly and data loss may occur Furthermore Fujitsu cannot be held responsible for any related damage malfunction or loss of data etc Be sure to wait for 10 seconds or more after shutdown before turning the server on again After connecting all power cords wait at least 10 seconds ...

Страница 78: ...ge 65 lights up green Ê Shut down the operating system properly The server is automatically switched off The AC connected indicator lights up green I If the operating system does not switch the server off automatically press the On Off button for at least four seconds and or send a corresponding control signal V CAUTION There is a risk that data may be lost Other On Off options Besides the On Off ...

Страница 79: ...ower failure The server automatically reboots following a power failure depending of the settings in the BIOS IPMI The server is switched on by an IPMI console via serial port COM1 see figure 7 on page 55 or via the management LAN connection see figure 7 on page 55 ...

Страница 80: ...allation Manager Using the ServerView Installation Manager is recommended I The controller has its own configuration utility For further information refer to the Embedded MegaRAID Software User s Guide on the Fujitsu manuals server under x86 Servers Expansion Cards Storage Adapters LSI Configuration Software I Descriptions of operating systems not covered in the controller manual are provided in t...

Страница 81: ...on refer to the LSI MegaRAID SAS Software User Guide on the Fujitsu manuals server under x86 Servers Expansion Cards Storage Adapters LSI Configuration Software Further information on modular RAID controllers is provided in the Modular RAID Controller Installation Guide on the Fujitsu manuals server under x86 Servers Expansion Cards Storage Adapters LSI SAS SCSI RAID Controllers I Descriptions of ...

Страница 82: ...onfiguration files for unattended installation of several PRIMERGY servers with identical hardware configurations Installation of drivers and additional software I The software that can be installed depends on your server s hardware configuration This configuration is detected automatically I Descriptions of operating systems not covered in the RAID controller manual are provided in the correspond...

Страница 83: ...ontroller as described in section Configuring the onboard SATA controller on page 80 Configuring the SAS SATA RAID controller Configure the controller as described in section Configuring the onboard SATA controller on page 80 Installing the operating system Ê Insert the CD DVD for the operating system you want to install Ê Reboot the server Ê Follow the instructions on screen and in the manual for...

Страница 84: ...agents that contain abrasives or may corrode plastic Ensure that no liquid enters the system Ensure that the ventilation areas of the server and the monitor are clear Do not use any cleaning sprays including flammable types It may cause a device failure or a fire Clean the keyboard and the mouse with a disinfecting cloth Wipe the server and monitor casing with a dry cloth If particularly dirty use...

Страница 85: ... fixed object with a steel cable running through a clip on the back 7 2 BIOS Setup security functions The Security menu in BIOS Setup offers various options for protecting your data from unauthorized access By combining these options you can also achieve optimum protection for your system I A detailed description of the Security menu and how to assign passwords can be found in the D3373 BIOS Setup...

Страница 86: ...86 Operating Manual TX1320 M3 Property and data protection ...

Страница 87: ...ist of the steps performed and the circumstances that led to the fault Also make a list of any error messages that were displayed Ê Switch off the server Ê Contact our customer service team 8 1 Power on indicator remains unlit The power on indicator remains dark after you switch on your device Power cable incorrectly connected Ê Make sure that the power cable s is are correctly connected to the se...

Страница 88: ...iate password Brightness control is set to dark Ê Set the brightness control on the monitor to light For detailed information refer to the operating manual supplied with your monitor Power cable or monitor cable not connected Ê Switch off the monitor and the server Ê Check whether the power cable is properly connected to the monitor and to the grounded power outlet Ê Check whether the monitor cabl...

Страница 89: ...een display or display drifts The wrong horizontal frequency or resolution has been selected for the monitor or for the application program Ê Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor Ê Refer to the documentation for your operating syst...

Страница 90: ...l or contact our customer service team 8 8 Drives reported as dead when starting system This error message can occur when the onboard SAS controller has RAID functionality or the server is equipped with a PCI RAID controller RAID controller configuration incorrect Ê Check and correct the settings for the drives using the RAID controller utility Further information is provided in the manual for the...

Страница 91: ...Operating Manual 91 Troubleshooting and tips 8 10 Error message on screen The meaning of the error message is explained in the documentation for the relevant components and programs on the Fujitsu manuals server ...

Страница 92: ...92 Operating Manual TX1320 M3 Troubleshooting and tips ...

Отзывы: