26
Operating Manual
TX1320 M3
Functional overview
Dimensions / Weight
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Upright operating
position (W x D x H)
193 mm x 438 mm x 360 mm (including feet)
Horizontal operating
position (W x D x H)
340 mm x 400 mm x 101 mm
Weight
up to 11 kg
Weight notes
Weight may vary depending on actual configuration
Environment class 3K2
Environment class 2K2
EN60721 / IEC 721 Part 3-3
EN60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
5°C ... 40°C (with ATD)
10°C ... 35°C (without ATD)
Transport (2K2)
-25 °C ... 60 °C
Humidity
10% ... 85% (non condensing)