For Windows Server 2008 R2 and above
▶
Click
Start
-
Control Panel
-
System and Security
-
BitLocker Drive
Encryption
to open the BitLocker Drive Encryption.
▶
Select the system volume, and click
Resume Protection
.
For more information on how to resume BitLocker drive encryption, see
the Microsoft TechNet library at:
https://technet.microsoft.com/library/cc731549.aspx
For more information, see the Fujitsu web pages.
5.2.8
Performing a RAID array rebuild
After replacing an HDD that has been combined into a RAID array, RAID
rebuild will be performed unattended as a background process. Depending on
your RAID controller, you may need to manually start a RAID rebuild.
▶
Ensure that the RAID array rebuild has started normally. Wait until the
progress has reached at least one percent.
The progress is indicated in
PCSysscan_Report.xml
collected by Prime
Collect.
▶
Open
PCsysscan_Report.xml
and check RebuildProgress.
In
PCsysscan_Report.xml
:
<Activity>Rebuilding</Activity>
<Status>Degraded</Status>
<RebuildProgress>1</RebuildProgress>
<ArrayName>SATA_Array_0000</ArrayName>
The number "1" in the text above indicates that the rebuild progress is at
one percent.
Basic software procedures
TX1310 M5
Upgrade and Maintenance Manual
69
Содержание PRIMERGY TX1310 M5
Страница 14: ...Content Upgrade and Maintenance Manual TX1310 M5 ...
Страница 80: ...Power supply unit PSU 80 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 124: ...Expansion cards 124 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 156: ...Processor CPU 156 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 174: ...Front panel and front USB 174 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 216: ...System board and components 216 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 238: ...Appendix A 238 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 240: ...FUJITSU Server PRIMERGY TX1310 M5 Reference Manual Reference Manual English Cable plan for March 2022 ...
Страница 257: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT July 2021 ...