Installing in a Rack
This chapter explains the procedure for installing this product in the rack.
3.1
Condition of Installation Location
When installing this product, avoid the following areas.
• Humid, dusty, or oily areas
• Poorly ventilated area
• Area close to fire or other sources of heat
• Area with a temperature of below 10
°
C or above 35
°
C
• Area with humidity of less than 20% or more than 80%
• Area where cables become trip hazards
• Area where strong magnetic fields are generated, such as near TVs and speakers.
• Area close to water
• Areas close to direct sunlight or near heating appliances
• Areas where corrosive gas is generated
• Salty areas
• Areas where the device is not stable and could tip over and hurt somebody