The FFx-RAID Controller Module
Plug-in Board Modules
The individual DIP switch positions ON have the following function:
8.1.3
Installing/removing the FFx-RAID controller
module
V
CAUTION!
Observe the notes on safety and the information on electrostatic
sensitive device labeling in chapter “Important Notes” on page 7.
The FFx-RAID controller module can be installed and removed while the
subsystem is running provided that the configuration involved is a dual-active
configuration (two modules with dual-active configuration have been installed)
and the
MultiPath
software is active. If one FFx-RAID controller module is
removed, the second module automatically takes over its function (hot swap).
V
CAUTION!
As condition for a hot swap action the replaced FFx-RAID controller
modules (FFx-RAID controller) must have the same firmware version
and the same cache memory size.
DIP switch Function
J1
ON Manufactory Diagnosis Mode activated: status indicator LEDs
(red, green, yellow) for the FFx-RAID controller flash 0.5 sec.
J2
ON Debug Mode
J3
ON Disable HSSDC NODE
J4
ON Disable GBIC NODE
K1
ON Conservative Cache active
K2
ON Enable delayed FFx-RAID controller power ON (delay ca. 17 sec.)
K3
ON Enable/Reset FFx-RAID controller from I2C bus active
K4
ON Multi Frame Mode: node ON/OFF after 4 consecutive erroneous
or error-free frames
Table 13: DIP Switches: Functions
Содержание PRIMERGY S60
Страница 3: ...German English ...
Страница 4: ......
Страница 8: ......
Страница 14: ......
Страница 22: ......
Страница 32: ......
Страница 36: ......
Страница 40: ......
Страница 44: ......
Страница 52: ......
Страница 78: ......
Страница 88: ......
Страница 90: ......
Страница 94: ......
Страница 96: ......
Страница 98: ......