
46
U41221-J-Z156-1-74
The FFx-RAID Controller Module
Plug-in Board Modules
8.1.1
Indicators and Connectors
The integrated FC-HUB provides the standard host-interface (two nodes) for
the storage subsystem. One node will be connected via a fixed HSSDC
connector (11) (see figure 19 on page 47) available only for cooper cable up to
10 m.
The other node will be connected via a GBIC (Gigabit Interface Converter) (12).
The FC-transmission medium (CU/HSSDC, MMF or SMF) depends on the type
of GBIC being used.
I
Perfect functioning will be ensured only by the use of the GBIC types
released by Fujitsu Siemens Computers GmbH.
LEDs indicate the operating status of the module, of the corresponding nodes
and/or loop and the channel activity (see tables under „Description of the LED
indicators“ on the following pages).
To configure the FFx-RAID controller, use the VT100 Terminal-Emulation-
Interface (see “Related publications” on page 81) or SAM (SAN Array Manager)
software. The VT100 Terminal-Emulation-Interface can be connected via the
VT100-DEBUG connector (10).
Содержание PRIMERGY S60
Страница 3: ...German English ...
Страница 4: ......
Страница 8: ......
Страница 14: ......
Страница 22: ......
Страница 32: ......
Страница 36: ......
Страница 40: ......
Страница 44: ......
Страница 52: ......
Страница 78: ......
Страница 88: ......
Страница 90: ......
Страница 94: ......
Страница 96: ......
Страница 98: ......