90
Maintenance Manual
RX900
S1
Hard disk and solid state drives
6. Remove all CPUMEMRs, see
"Removing the CPUMEMR" on page 190
I
Before removing the CPUMEMRs, take a note on the installation
slot number for each CPUMEMR. Make sure that you reinstall the
CPUMEMR in the slot it was located before the SAS backplane
replacement.
7. Unlock and remove all HDD/SSD modules, see
"Unlocking the HDD/SSD
module" on page 82
and
"Removing the HDD/SSD module" on page 86
.
I
Before removing the HDD/SSD modules, take a note on the bay
number for each module. Make sure that you reinstall the module
in the bay it was located before the SAS backplane replacement.
6.4.3
Sliding the local service display outward
Figure 39: Sliding the local service display outward
Ê
Unlock the local service display (1).
Ê
Slide the local service display outward a few centimeters so that you have
free access (2).
/
0
Содержание PRIMERGY RX900 S1
Страница 1: ...Maintenance Manual English PRIMERGY RX900 S1 Server Maintenance Manual Edition August 2010 ...
Страница 6: ...6 Maintenance Manual RX900 S1 ...
Страница 52: ...52 Maintenance Manual RX900 S1 Basic procedures ...
Страница 100: ...100 Maintenance Manual RX900 S1 Hard disk and solid state drives ...
Страница 180: ...180 Maintenance Manual RX900 S1 Expansion cards and BBU ...
Страница 198: ...198 Maintenance Manual RX900 S1 Main memory ...
Страница 226: ...226 Maintenance Manual RX900 S1 Optical and backup drives ...
Страница 246: ...246 Maintenance Manual RX900 S1 Front panel and external connectors ...
Страница 260: ...260 Maintenance Manual RX900 S1 Management and diagnostics modules ...
Страница 350: ...350 Maintenance Manual RX900 S1 Cables ...
Страница 368: ...368 Maintenance Manual RX900 S1 Appendix ...