RX900 S1
Maintenance Manual
205
Processors
10.1.6 Installing the heat sink
Figure 121: Installing the heat sink
Ê
Carefully place the heat sink onto the processor.
V
CAUTION!
Place the heat sink precisely on the threaded holes (see circles).
Careless handling may damage conductors and render the
baseboard useless.
Ê
Fasten the heat sink with its five captive screws. Fasten the screws
alternately until they are fully tightened:
–
Give each screw about 4 turns at a time.
–
Start with screw 1 to screw 5 as indicated in
figure 121
and continue with
screw 1.
–
Torque: 0.6 Nm
/
0
1
2
3