Troubleshooting and tips Drives reported as “dead” when starting system

7.9

Drives reported as “dead” when starting 
system

This error message can occur when the onboard SAS controller has RAID 
functionality or the server is equipped with a PCI RAID controller.

RAID controller configuration incorrect

Ê

Check and correct the settings for the drives using the RAID controller utility.

Further information is provided in the manual for the RAID controller.

7.10

Added drive reported as defective

RAID controller is not configured for this drive

The drive was probably installed when the system was switched off.

Ê

Reconfigure the RAID controller for the drive using the corresponding utility. 
Information is provided in the documentation for the RAID controller.

or

Ê

Remove and reinstall the drive while the system is switched ON.

If the drive continues to be reported as defective, then replace it (see 

“Installing/removing the HDD module” on page 77

 and 

“Removing the HDD 

module” on page 79

).

7.11

Error message on screen

The meaning of the error message is explained in the manual for the 

BIOS-Setup

 

and in the documentation for the relevant components and programs on the 
PRIMERGY 

ServerBooks

 DVD.

Содержание PRIMERGY RX330 S1

Страница 1: ...PRIMERGY RX330 S1 Server Operating Manual Edition May 2007 ...

Страница 2: ...a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2007 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to av...

Страница 3: ...tement 28 3 4 Transporting the server 29 3 5 Notes on installing in the rack 30 3 6 Environmental protection 31 4 Hardware installation 33 4 1 Unpacking the server 34 4 2 Installing removing the server in from the rack 35 4 2 1 Installation in PRIMECENTER DataCenter Rack 39 4 2 2 Installation in 3rd party racks 42 4 2 3 Inserting the server 43 4 3 Connecting devices to the server 45 4 4 Connecting...

Страница 4: ...4 Cleaning the server 60 6 Property and data protection 61 6 1 BIOS Setup security functions 61 7 Troubleshooting and tips 63 7 1 Power on indicator remains unlit 63 7 2 Server switches itself off 64 7 3 Screen remains blank 64 7 4 Flickering stripes on monitor screen 65 7 5 No screen display or display drifts 65 7 6 No mouse pointer displayed on screen 65 7 7 Incorrect date and time 66 7 8 System...

Страница 5: ...70 8 1 2 Installing removing the hot plug power supply unit 71 8 1 3 Replacing the hot plug power supply unit 72 8 2 Hot plug hard disk drives 73 8 2 1 Handling hard disk drives and HDD modules 75 8 2 2 Removing Installing the dummy module 76 8 2 3 Installing removing the HDD module 77 Abbreviations 81 Literature 87 Index 89 ...

Страница 6: ......

Страница 7: ...ack 1 1 Documentation overview I PRIMERGY manuals are available in PDF format on the ServerBooks DVD The ServerBooks DVD is part of the ServerStart Suite supplied with every server The PDF files of the manuals can also be downloaded free of charge from the Internet The overview page showing the online documentation available on the Internet can be found using the URL http manuals fujitsu siemens c...

Страница 8: ...e available on the ServerBooks DVD supplied BIOS Setup PDF file available on the ServerBooks DVD supplied PRIMERGY RX330 S1 Server Options Guide PDF file available on the ServerBooks DVD I The Options Guide describes the server expansion and modifi cation options ServerView Suite includes the ServerStart Disc 1 the ServerStart Disc 2 and the ServerBooks DVD The version of the PRIMERGY ServerView S...

Страница 9: ... system board D2440 for the hardware and in the BIOS Setup for the firmware see Literature on page 87 Hard disk drives The server includes two drive cages with up to six 2x3 SAS SATA2 hard disk modules Each hard disk module can accommodate an SAS SATA2 hard disk drive with a maximum height of 1 inch The module is connected to the SAS SATA2 backplane wirelessly This allows hard disk drive modules t...

Страница 10: ...able for a CD DVD drive or a magnetic tape drive The accessible drive installed here cannot be replaced during operation USB port The USB interface on the front of the server supports activities carried out by the service technician The maximum length of the external cable are three meters Power supply The basic configuration of the server includes a hot plug power supply unit which automatically ...

Страница 11: ...y is provided by the hot plug HDD modules depending on the server variant iRMC with integrated service LAN port I The features of the iRMC Advanced Video Redirection and Remote Storage are available as an option The iRMC integrated Remote Management Controller is a BMC with integrated service LAN port and expanded functionality that was previously only available with additional plug in cards In th...

Страница 12: ...sole bypass Command Line Interface CLP Simple interactive or script based iRMC configuration iRMC s own user management Automatic network configuration via DNS DHCP Power supply to the iRMC via the system standby supply Full coverage alarm management System Error and Event Log SEL reading and processing More information about the iRMC can be found in the PRIMERGY ServerView Suite integrated Remote...

Страница 13: ...lock monitoring regardless of server status High performance graphical console bypass AVR protected by HTTPS SSL 128 bit Remote storage via USB Remote power on Wake On LAN Automatic switch off when the housing is opened Housing monitoring Temperature monitoring of the CPU and the surrounding area Watchdog timer for Automatic Server Reconfiguration and Restart ASR R in the event of failure of memor...

Страница 14: ...simple and immediate recognition In order to avoid damage to components by incorrect handling when they are being installed and removed green highlighting also identifies the areas of all components that can be touched without causing damage to the respective component The Flash EPROM program supplied with the Fujitsu Siemens Computers utilities supports a fast BIOS update With the iRMC integrated...

Страница 15: ... on site repairs and reduces service costs This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution The administrator can access all system information and information from the sensors such as fan speeds or voltages via the iRMC s Web interface see section iRMC with integrated service LAN port on page 11 He can also start the...

Страница 16: ...u items or software programs Quotation marks indicate names of chapters and terms that are being emphasized Ê describes activities that must be performed in the order shown V CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates additional information notes and tips ...

Страница 17: ...arent power 462 VA Heat dissipation 1630 kJ h 1545 btu h Main power fuse 16 A Protection class I Product safety and ergonomics IEC 60950 1 EN 60950 1 UL CSA 60950 1 CNS 14336 GB 4943 EN 50371 Electromagnetic compatibility FCC class A CNS 13438 class A VCCI class A AS NZS CISPR 22 class A GB 9254 class A GB 17625 Interference emissions EN 55022 class A Harmonic current EN 61000 3 2 Flicker EN 61000...

Страница 18: ...idth 431 mm Depth 686 mm Height 87 mm 2 HU Installation depth in the rack 651 mm Cable depth in the rack 200 0 mm 1000 mm rack recommended Environment class 3K2 Environment class 2K2 EN 60721 IEC 721 Part 3 3 EN 60721 IEC 721 Part 3 2 Temperature Operation 3K2 10 C 35 C Transport 2K2 25 C 60 C Humidity 10 85 Sound power level LWAd ISO 9296 6 6 B standby 7 3 B operation Sound pressure level at adja...

Страница 19: ...ts Keep these parts in a safe place They are designed to be used for installing optional components at a later time Ê Transport the server to the place where you want to install it Ê Make sure that all necessary manuals see Additional server documen tation on page 8 are available print out the PDF files if required Ê Mount the server into the rack see Installing removing the server in from the rac...

Страница 20: ...ional infor mation can be found in the PRIMERGY ServerView Suite ServerStart manual Configuration information can also be found in the Configuration with ServerStart on page 59 section Local configuration and installation with or without ServerStart see the Configuration with ServerStart on page 59 section or the Configuration without ServerStart on page 60 section I You will find more information...

Страница 21: ...ent If you have any questions about where you can set up the device contact your sales outlet or our customer service team V CAUTION The actions described in this manual should only be performed by technical specialists Equipment repairs should only be performed by service personnel Any unauthorized opening and improper repairs could expose the user to risks electric shock energy hazards fire haza...

Страница 22: ... protects it from impacts and jolts Installation and operation V CAUTION This unit should not be operated in ambient temperatures above 35 C If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for type A connector...

Страница 23: ... EN 50173 and EN 50174 1 2 standards apply for LAN cabling The minimum requirement is the use of a category 5 screened LAN cable for 10 100 Mbps Ethernet or a category 5e cable for Gigabit Ethernet The requirements from the ISO IEC 11801 specification must also be met Route the cables in such a way that they do not create a potential hazard make sure no one can trip over them and that they cannot ...

Страница 24: ...ions they may damage the system or violate the safety regulations Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet The components marked with a warning notice e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel Exception hot pluggable power supply units can be replac...

Страница 25: ...es sharp CD DVD fragments can pierce the cover of the CD DVD drive equipment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck I You can prevent mechanical damage and damage to the CD DVD drive as well as premature CD DVD wear by observing the following sugges tions Only insert CDs DVDs in the drive when needed and remove them after...

Страница 26: ...must be disposed of in accordance with local regulations concerning special waste The battery must be disposed of in accordance with local regulations concerning special waste Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board see Literature on page 87 All batteries containing pollutants are marked with a symbol a crosse...

Страница 27: ...always discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or conduction p...

Страница 28: ...CC rules and meets all requirements of the Canadian Interference Causing Equipment Standard ICES 003 for digital apparatus These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in strict accordance with the instructions may cause harmful...

Страница 29: ...orrection of interferences caused by such unauthorized modification substitution or attachment will be the responsibility of the user The use of shielded I O cables is required when connecting this equipment to any and all optional peripheral or host devices Failure to do so may violate FCC and ICES rules WARNING This is a class A product In a domestic environment this product may cause radio inte...

Страница 30: ...ed with the corresponding rack When installing the rack make sure that the anti tilt mechanism is correctly fitted For safety reasons no more than one unit may be removed from the rack at any one time during installation and maintenance work If several units are simultaneously removed from the rack there is a risk that the rack could tip over The rack must be connected to the power supply by an au...

Страница 31: ...il they are needed as well as during long breaks and after completion of work Packaging information Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulati...

Страница 32: ...tsu Siemens Computers branch or from our recycling center in Paderborn Fujitsu Siemens Computers Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EC on waste electrical and electronic equipment WEEE This directive sets the framework for returning and...

Страница 33: ...ty and heat Make sure that the server is acclimatized for the time indicated in this table before putting it into operation In table Acclimatization time the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously outside transport or storage temperature Temperature difference C Minimum acclimatiza...

Страница 34: ...on Ê Transport the server to the place where you want to set it up Ê Unpack all individual parts Keep the original packaging in case you want to transport the server again Ê Check the delivery for any damage during transport Ê Check whether the items delivered match the details on the delivery note The product name and serial number of the product can be found on the identi fication rating plate Ê...

Страница 35: ...ay not occupy the top height unit of the rack 38 HU 42 HU PRIMECENTER Rack and or DataCenter Rack as otherwise boards or fans cannot be replaced even with the plug in module fully extended Rack requirements The rack systems from Fujitsu Siemens Computers PRIMECENTER Rack and DataCenter Rack support installation of PRIMERGY servers Installation in most current rack systems from other manufacturers ...

Страница 36: ... they can be adjusted to different rack depths Enhanced cable management in the lateral rack area DataCenter Rack Telescopic rails screwed to the front except in the rear left area where a support bracket is used Enhanced cable management in the lateral rack area The mounting of the rails in the different racks is described in the next sections Installation of the cable management is described in ...

Страница 37: ...nditions An unobstructed air intake in the rack front and air discharge in the rear cover of the rack are essential for ventilation of the installed server In principle the ventilation concept plans that the necessary cooling is reached by the horizontal self ventilation of the installed devices air flow from the front to the rear 1 Front of rack 2 Rear of rack A Rack depth comparison PRIMECENTER ...

Страница 38: ...X330 S1 Installing removing the server in from the rack Hardware installation Power supply For installation in 3rd party racks you must ensure that the appropriate socket strips are present Figure 2 Mechanical requirements ...

Страница 39: ...pport uprights and the support bracket The descriptions and figures in this section refer to the current variable support General information is provided in the Technical Manual for the PRIMECENTER and or DataCenter Rack see Literature on page 87 When mounting the left telescopic rail in the PRIMECENTER DataCenter Rack the supplied support bracket must first be mounted on the rear left support upr...

Страница 40: ...ion Figure 4 Remove the outer telescopic rail Ê Extend the telescopic rail fully 1 Ê Press the release spring 2 and remove the server rail Ê Repeat both steps with the second telescopic rail I No nuts are required to secure the telescopic rails as the fixing holes on the rails are threaded 1 1 2 ...

Страница 41: ...ont end passes behind the front left support upright 2 then release Ê Secure the rail on the front left support upright 3 and the support bracket in the rack 4 with two M5 screws each Ê Repeat the steps with the right telescopic rail to be secured to the right support uprights Ê Fit the PRIMECENTER DataCenter Rack cable management as described in the technical manual for the rack Ê Insert the serv...

Страница 42: ...CAUTION For installation in 3rd party racks it must be ensured that an air flow from the front to the back of the rack is guaranteed Ê Fit the required original parts support bracket or cable management system I Under certain circumstances you will not be able to use some of the parts from the rack installation kit supplied you will need to use original 3rd party rack parts instead Ê Remove the ou...

Страница 43: ...ength is adjusted with the spring element on the variable support Ê Secure the telescopic rails as described in section Installation in PRIME CENTER DataCenter Rack on page 39 Ê Mount the server see section Inserting the server on page 43 and route the cables as described in the rack manual 4 2 3 Inserting the server Figure 6 Preparing the server Ê Place the server rails on the three screws on bot...

Страница 44: ...to place so that they can no longer be moved Ê Push the prepared server into the rails that are attached to the rack until the server rails engage 2 I Ensure that the server is inserted horizontally and is not tilted Ê Press the safety springs in on both sides 3 Ê Gently push the server as far as it will go into the rack 4 Ê Fasten the server to the rack 5 using the two knurled screws front panel ...

Страница 45: ... color coded Figure 8 Ports on the rear I Some of the devices that can be connected may require special drivers see the documentation for the connected device Ê Connect the desired devices to the server You can find an additional USB port 1 on the front of the server figure 9 1 Mouse port PS 2 green 6 2 x USB ports black 2 Serial port COM 2 turquoise 7 Monitor port VGA blue 3 Service LAN port 8 Se...

Страница 46: ...I If a separate graphics card is installed in a slot the graphic controller on the system board is automatically deactivated The corresponding monitor port VGA can not be used Plug the data cable of the monitor into the monitor port of the graphics card Ê Connect the power cable of the monitor to the mains socket strip of the rack I The rated current for the monitor can be found on the technical d...

Страница 47: ...ply units automatically set themselves to a mains voltage in the range of 100 V 127 V or 200 V 240 V Make sure that your local mains voltage is within the correct range Figure 10 Connecting the server to the mains Ê Connect the power cable with the insulated connector 1 to the power supply unit of the server and plug the power plug 2 into a grounded outlet on the mains socket strip on the rack see...

Страница 48: ...isconnect external devices to or from the server Connecting cables Ê Turn off all power and equipment switches Ê Disconnect all power plugs from the grounded shockproof sockets Ê Connect all cables to the server and peripherals Ê Plug all data communication cables into the utility sockets Ê Plug all power cables into the grounded shockproof sockets Disconnecting cables Ê Turn off all power and equ...

Страница 49: ...5 1 Controls and displays 5 1 1 Front of server Figure 11 Controls and indicators on the front 1 HDD BUSY indicator 7 On Off button 2 HDD FAULT indicator 8 Global error indicator 3 CD DVD indicator 9 Drive access indicator 4 ID indicator 10 Power on indicator 5 Reset button 11 ID button 6 NMI button 1 2 3 4 5 6 8 9 10 11 7 1 2 3 4 5 6 8 9 10 11 7 ...

Страница 50: ...et button Pressing the reset button reboots the system ID ID button Lights up blue on the front and on the rear of the server when the ID button is pressed The two ID indicators are synchronized Power on indicator three colors Lights red when the server is switched off but line voltage is present Lights yellow during power up delay I If the server is switched off and then immediately switched on a...

Страница 51: ...p red when a predictable error has been detected Users can check the system and event log or via ServerView for more detailed information Flashes red when a critical event has occurred Users can check for event details in the BIOS Setup the system and event log or via ServerView If the event is still acute after a power failure the indicator is activated after the restart ID ID indicator blue Ligh...

Страница 52: ...ion with a RAID controller does not light no HDD error Lit HDD Faulty or Rebuild Stopped drive defective needs replacing a rebuild process was stopped or the HDD module is not correctly inserted Slow flashing HDD Rebuild the data is being restored after changing a hard disk drive Fast flashing HDD Identify four fast blinks pause HDD Predicted Fault Two fast flashes pause HDD Hot Spare Hot spare dr...

Страница 53: ...The two ID indicators are synchronized The ID indicator can also be activated via ServerView and its status reported to ServerView 2 Global Error indicator red Does not light up when the system is OK No service incident or critical event has occurred Lights up red when a predictable error has been detected Users can check the system and event log or via ServerView for more detailed information Fla...

Страница 54: ... LAN transfer rate indicator service LAN Lights up green for a LAN transfer rate of 100 Mbps Does not light up for a LAN transfer rate of 10 Mbps 3 LAN link Active indicator standard LAN Lights up green if a LAN connection exists Does not light up if no LAN connection exists Flashes green when a LAN transfer is in progress 4 LAN transfer rate indicator standard LAN Lights yellow for a LAN transfer...

Страница 55: ...ting up and operation Controls and displays Hot plug PSU indicators Figure 15 Hot plug PSU indicators LED Status Meaning 1 AC On Mains voltage on Off Mains voltage off 2 DC On PSU in operation Off PSU in standby mode or failed 1 2 1 2 ...

Страница 56: ...wer on indicator item 10 in figure 11 on page 49 lights red Starting up for the first time Ê Press the On Off button position 7 in figure 11 on page 49 The power on indicator lights up green item 10 in figure figure 11 on page 49 Ê Insert ServerStart disc 1 in the CD DVD drive Ê Follow the on screen instructions see also section Configuration with ServerStart on page 59 or section Configuration wi...

Страница 57: ...on off options In addition to the On Off button the server can be switched ON and OFF in the following ways Specified switch on time switch off time The server is switched ON or OFF at a time specified in the ServerView program Ring indicator The server is switched on by an internal or external modem Wake On LAN WOL The server is switched on by a command via the LAN Magic Packet After power failur...

Страница 58: ...the BIOS Setup during server operation 5 3 1 Configuring onboard SAS controller The server has an onboard SAS controller with Integrated Mirroring Enhanced functionality You can configure the Onboard SAS Controller either before or during ServerStart Using ServerStart is recommended I A separate utility is available to the controller for IME configuration Further information can be found in the In...

Страница 59: ...ration files for unattended installation of several PRIMERGY servers with identical hardware configurations Installation of drivers and additional software I The software that can be installed depends on your server s hardware configuration This configuration is detected automatically I Descriptions of operating systems not covered in the RAID controller manual are provided in the appropriate read...

Страница 60: ... read how to install the desired operating system in the related manual 5 4 Cleaning the server V CAUTION Switch the server off and disconnect the power plugs from the grounded shockproof sockets Do not clean any interior parts yourself leave this job to a service technician Do not use any cleaning agents that contain abrasives or may corrode plastic Ensure that no liquid enters the system Ensure ...

Страница 61: ... on the ServerBooks DVD see Literature on page 87 Preventing unauthorized BIOS Setup calls You can activate this protection by entering a setup password in the Security menu You can also suppress the Press F2 for Setup message in this menu This message is then no longer displayed while the server s startup routine is in progress Preventing unauthorized system access You can activate this protectio...

Страница 62: ...from being overwritten To activate this protection select the value Disabled for the Flash Write field in the Security menu Protecting the server from being switched on by an external device To activate this protection select the value Disabled for the Remote Power On field in the Security menu Protecting the server from being switched off by a program To activate this protection select the value ...

Страница 63: ...lows Ê Make a list of the steps performed and the circumstances that led to the fault Also make a list of any error messages that were displayed Ê Switch off the server Ê Contact our customer service team 7 1 Power on indicator remains unlit The power on indicator remains dark after you switch on your device Power cable incorrectly connected Ê Make sure that the power cable s is are correctly conn...

Страница 64: ...te password Brightness control is set to dark Ê Set the brightness control on the monitor to light For detailed information refer to the operating manual supplied with your monitor Power cable or monitor cable not connected Ê Switch off the monitor and the server Ê Check whether the power cable is properly connected to the monitor and to the grounded socket Ê Check whether the monitor cable is pro...

Страница 65: ...rdingly 7 5 No screen display or display drifts The wrong horizontal frequency or resolution has been selected for the monitor or for the application program Ê Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor Ê Refer to the documentation for y...

Страница 66: ...ay affect the system time For example the operating system time may deviate from the system time under Linux and would overwrite the system time in the default setting on shutdown If the date and time are still wrong after the server has been switched off and back on again replace the lithium battery for a description refer to the Technical Manual for the D2440 system board or contact our customer...

Страница 67: ...s defective RAID controller is not configured for this drive The drive was probably installed when the system was switched off Ê Reconfigure the RAID controller for the drive using the corresponding utility Information is provided in the documentation for the RAID controller or Ê Remove and reinstall the drive while the system is switched ON If the drive continues to be reported as defective then ...

Страница 68: ......

Страница 69: ...nd may only be performed by authorized specialist personnel The hot plug procedure increases the availability of system operation and guarantees a high degree of data integrity and failsafe performance V CAUTION Follow the safety instructions in the chapter Important information on page 21 8 1 Hot plug power supply units I A redundant power supply can be created by installing a second hot pluggabl...

Страница 70: ...ond power supply unit Figure 16 Remove the dummy module Ê Loosen the fixing screw 1 and remove the dummy module from the second power supply mounting location 2 V CAUTION Store the dummy module in a safe place If the power supply unit is removed and not replaced with a new unit the dummy module must be reinstalled due to cooling to comply with applicable EMC regulations regulations on electromagne...

Страница 71: ... the locking lever 1 and slide the power supply unit into the mounting location 2 as far as it will go The locking lever will turn upwards and engage Ê Check that the locking lever is properly locked in place If necessary push the lever up Ê Connect the power supply unit to the mains see section Connecting the server to the mains on page 47 To remove the server follow this procedure in reverse 1 2...

Страница 72: ...ly unit Ê Remove the defective power supply unit see section Installing removing the hot plug power supply unit on page 71 Ê Install the new power supply unit in the empty mounting location see section Installing removing the hot plug power supply unit on page 71 I Make sure that the power supply unit engages correctly in the mounting location and is locked in position This is the only way to avoi...

Страница 73: ...ation frame together make up the HDD module V CAUTION The HDD must not be removed from the installation frame by anyone except a service technician The HDD modules drives must all be marked clearly so that they can be put back in their original places after an upgrade If this is not done existing data can be lost The hot plug function is only possible in conjunction with a corre sponding RAID conf...

Страница 74: ...talled 2 Indicators HDD Busy LED green HDD Fault LED orange For description see section Indicators on the HDD module on page 52 3 Handle for locking and unlocking the HDD module 4 Button for locking and unlocking the handle 5 Ridge for the application of a sticker with the current drive name 6 Dummy module 7 Tabs for unlocking the dummy module 1 6 7 5 4 3 2 4 ...

Страница 75: ...sport HDD modules within the limits stipulated in the specification When transporting HDD modules even over short distances always use the original packaging ESD label Never expose HDD modules to a temperature shock Avoid the formation of condensation inside and on the outside of the hard disk drive V CAUTION The HDD module must be acclimatized in its operating environment for an acclimatization t...

Страница 76: ...er until the locking mechanism disengages 1 Ê Pull the dummy module out of the slot 2 To install a dummy module follow the same procedure in reverse order V CAUTION Store the dummy module in a safe place If you have removed an HDD module and do not install a new one in its place put the dummy module back in its place for cooling to comply with EMC regulations regulations regarding electromagnetic ...

Страница 77: ... a transport lock remove the lock before releasing the locking mechanism Figure 19 Removing the transport lock Ê Pull the transport lock out in the direction of the arrow Figure 20 Unlocking the HDD module Ê Open the locking mechanism by pressing the locking button 1 Ê Push the handle of the HDD module fully in the direction of the arrow 2 The HDD module is now unlocked 1 2 ...

Страница 78: ...Figure 21 Installing the HDD module Ê Unlock the HDD module as described in section Unlocking the HDD module on page 77 Ê Carefully push the HDD module into the empty mounting location 1 until it stops Ê Push the handle completely in the direction of the arrow 2 until the locking mechanism engages 1 2 ...

Страница 79: ... conjunction with a corresponding RAID configuration All HDD modules drives must be uniquely identified so that they can be reinstalled in their original mounting locations later If this is not done existing data can be lost If you want to remove an HDD module during operation proceed as follows Ê If you want to remove a HDD module that is not defective the drive must be first set to offline via t...

Страница 80: ...77 and Installing the HDD module on page 78 V CAUTION If you have removed an HDD module and do not install a new one in its place put the dummy module back in its place for cooling to comply with EMC regulations regulations regarding electromagnetic compatibility and for protection against fire Ensure that the dummy module engages correctly in the slot ...

Страница 81: ...Server Reconfiguration and Restart ATA Advanced Technology Attachments BIOS Basic Input Output System BMC Baseboard Management Controller CC Cache Coherency CD Compact Disk CD ROM Compact Disk Read Only Memory CHS Cylinder Head Sector CMOS Complementary Metal Oxide Semiconductor COM Communication CPU Central Processing Unit ...

Страница 82: ... and Correcting ECP Extended Capabilities Port EEPROM Electrically Erasable Programmable Read Only Memory EGB Elektrostatisch Gefärdete Bauteile component are in danger of electro static EMP Emergency Management Port EPP Enhanced Parallel Port EMV Elektromagnetische Verträglichkeit electromagnetic compatibility ESD ElectroStatic Discharge elektrostatische Entladung FPC Front Panel Controller ...

Страница 83: ...erface HDD Hard Disk Drive HSC Hot Swap Controller I C Inter Integrated Circuit I O Input Output ICM Intelligent Chassis Management ID Identification IDE Intergrated Drive Electronics IME Intergrated Mirroring Enhanced iRMC integrated Remote Management Controller IRQ Interrupt Request Line LAN Local Area Network ...

Страница 84: ...e Differential LWL LichtWellenLeiter fiber optic cable MMF Multi Mode Faser MRL Manually Retention Latch NMI Non Maskable Interrupt NVRAM Non Volatile Random Access Memory OS Operating System PCI Peripheral Component Interconnect PDA Prefailure Detection and Analysing POST Power ON Self Test RAID Redundant Arrays of Independent Disks ...

Страница 85: ...e Clock RTDS Remote Test und Diagnose System SAF TE SCSI Accessed Fault Tolerance Enclosures SAS Serial Attached SCSI SATA Serial ATA SBE Single Bit Error SCA Single Connector Attachment SCSI Small Computer System Interface SDDC Single Device Data Correction SDR Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory ...

Страница 86: ... Operating manual RX330 S1 Abbreviations SEL System Event Log SMI System Management Interrupt SSU System Setup Utility SVGA Super Video Graphics Adapter USB Universal Serial Bus VGA Video Graphics Adapter ...

Страница 87: ...tion available on the Internet can be found at the URL http manuals fujitsu siemens com The server PRIMERGY documentation can be accessed using the Industry standard servers navigation option 1 Safety notes and other important information 2 Warranty 3 Ergonomics 4 Returning used devices 5 Quick Start Hardware PRIMERGY RX330 S1 Leaflet 6 Quick Start Software Quick Installation Guide Leaflet 7 PRIME...

Страница 88: ...RIMERGY ServerView Suite integrated Remote Management Controller iRMC 14 ServerView RAID User manual 15 Integrated RAID for SAS User s guide 16 LSI SATA Software RAID User s guide 17 Integrated Mirroring User s guide 18 PRIMECENTER Rack Technical manual 19 DataCenter Rack Technical manual 20 19 Zoll Rack 19 inch rack Technical manual 21 PRIMERGY ServerView Suite RemoteView User manual ...

Страница 89: ... 7 software 7 Configuration server 58 Configuring onboard SAS controller 60 Configuring RAID 58 Connecting cables 48 Connecting devices to the server 45 Connecting external devices 45 Connections 45 Consumables 31 Control panel 49 Controls 49 Correcting faults 63 D Data manipulation 7 Data protection 61 Data security 10 DataCenter Rack requirements 36 Date incorrect 66 Delivery note 19 34 Disconne...

Страница 90: ...C statement 28 Features 9 Flash EPROM 14 G Global Error indicator 49 51 53 Graphics card 46 H Hard disk drive 9 handling 75 hard disk module 73 hot plug hard disk drive 73 indicator 51 52 installation frame 73 replacing online 79 Hard disk module dummy module 73 handling 73 HDD module 11 acclimatization time 33 75 installation frame 77 installing removing 77 Hot plug HDD module 11 73 Hot plug powe...

Страница 91: ...onnecting server 47 meaning of the symbols 16 Memory module hot spare memory 11 Memory scrubbing 10 Monitor display drifts 65 no display 65 Mouse port 45 Mouse no mouse pointer on screen 65 N NMI button 49 50 Noise level 18 Norms and standards 17 Notational conventions 16 O On Off button 49 50 Operating system installation 60 Operation 49 Overload 13 P Packaging 31 34 PDA 11 13 Ports keyboard port...

Страница 92: ... 7 setup password 61 system password 61 unauthorized access 61 Server ambient conditions 18 configuration 14 58 connecting mains voltage 47 dimensions 18 electrical data 17 fitting in rack 35 installation 43 installing 35 noise level 18 removing 35 routing cables 41 service 14 switches itself off error 64 switching off 56 switching on 56 technical data 17 transportation 29 unpacking 34 ventilation...

Страница 93: ...ating manual 93 Index Transport damage 19 34 Troubleshooting 63 U Unauthorized access 61 Unpacking server 34 USB port front of device 46 rear of device 45 service technician 10 V Ventilation clearance 18 W Weight 18 ...

Страница 94: ......

Отзывы: