Operating manual
RX330 S1
Controls and displays
Starting up and operation
Controls
Indicators on the control panel
On/Off button
When the system is switched off, it can be switched on again by
pressing the On/Off button. When the system is operating, pressing
the On/Off button will switch off the system.
I
The On/Off button does not disconnect the server from the
mains. To disconnect from the mains completely, remove the
power plug(s).
NMI
NMI button
I
Do not press! The NMI button may only be used by service
personnel.
RST
Reset button
Pressing the reset button reboots the system.
ID
ID button
Lights up (blue) on the front and on the rear of the server when the
ID button is pressed. The two ID indicators are synchronized.
Power-on indicator (three colors)
Lights red when the server is switched off but line voltage is
present.
Lights yellow during power up delay.
I
If the server is switched off and then immediately switched
on again, a server is only restarted after a power up delay.
This prevents a current overload, for example.
You can set the power up delay (in seconds) in the
BIOS
setup
in the
Server Menu
menu with
Power Cycle Delay
.
Lights up green when the server is switched ON.
Flashes green when the server has been switched on and is in
standby mode.