RX330 S1
Operating manual
41
Hardware installation
Installing/removing the server in/from the rack
Installing the telescopic rail with variable support
Figure 5: Fit the left telescopic rail in the PRIMECENTER/DataCenter Rack
Ê
Position the left-hand rail (1) in the support bracket with the vertical lug (a)
in the middle square catch.
Ê
Press the left rail together until its front end passes behind the front left
support upright (2), then release.
Ê
Secure the rail on the front left support upright (3) and the support bracket
in the rack (4) with two (M5) screws each.
Ê
Repeat the steps with the right telescopic rail (to be secured to the right
support uprights).
Ê
Fit the PRIMECENTER/DataCenter Rack cable management as described
in the technical manual for the rack.
Ê
Insert the server (see the
“Inserting the server” on page 43
section).
Ê
Route the cables once the server has been inserted, as described in the
Technical Manual for the rack in question.
a
1
4
3
2