TX2560 M2 / RX2560 M2
Upgrade and Maintenance Manual
113
Basic software procedures
Ê
Under
Boot Watchdog
, you can obtain detailed information about the current
watchdog status, time out intervals and actions that are triggered if
watchdog time outs are exceeded.
I
For detailed information on BIOS settings, refer to the corresponding
BIOS Setup Utility reference manual.
Viewing boot watchdog settings in the iRMC web frontend
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
Server Management
menu.
Ê
Under
Watchdog Settings
, you can obtain detailed information about the
current watchdog status, time out intervals and actions that are triggered if
watchdog time outs are exceeded.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
Viewing boot watchdog settings in ServerView Operations Manager
Ê
In ServerView Operations Manager
Single System View
select
Maintenance
from the
Information / Operation
menu.
Ê
Under
ASR&R
select the
Watchdog
tab to obtain detailed information about
the current watchdog status, time out intervals and actions that are triggered
if watchdog time outs are exceeded.
I
For more detailed information, refer to the "ServerView Operations
Manager - Server Management" user guide.
5.1.2.2
Configuring boot watchdog settings
If the system is to be started from removable boot media for firmware upgrade
purposes, the Boot watchdog needs to be disabled before starting maintenance
task. Otherwise, the Boot watchdog might initiate a system reboot before the
flash process is complete.
V
CAUTION!
An incomplete firmware upgrade process may render the server
inaccessible or result in damaged / destroyed hardware.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web frontend.
Содержание PRIMERGY RX2560 M2
Страница 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Страница 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Страница 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Страница 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Страница 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Страница 282: ...282 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Hard disk drive HDD solid state drive SSD ...
Страница 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Страница 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Страница 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Страница 508: ...508 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Converting a tower model to a rack model ...
Страница 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Страница 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...