Important information
●
If the server is brought in from a cold environment, condensation may form
both inside and on the outside of the server.
Wait until the server has acclimatized to room temperature and is absolutely
dry before starting it up. Material damage may be caused to the server if this
requirement is not observed.
●
Only transport the server in its original packaging or in packaging that
protects it from impacts and jolts.
In Japan and APAC, transporting the server in its original packaging does
not apply.
Installation and operation
●
This server should not be operated in ambient temperatures above 35 °C.
For servers with Advanced Thermal Design the ambient temperature can
increase to 40 °C or 45 °C.
●
If the server is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
●
The server automatically adjusts itself to a mains voltage, see the type label
of your server. Ensure that the local mains voltage lies within these limits.
●
This server must only be connected to properly grounded power outlets or
connected to the grounded rack internal power distribution server with
tested and approved power cords.
●
Ensure that the server is connected to a properly grounded power outlet
close to the server.
●
Ensure that the power sockets on the server and the properly grounded
power outlets are easily accessible.
●
The On/Off button or the main power switch (if present) does not isolate the
server from the mains power supply. In case of repair or servicing disconnect
the server completely from the mains power supply, unplug all power plugs
from the properly grounded power outlets.
●
Always connect the server and the attached peripheral devices to the same
power circuit. Otherwise you run the risk of losing data if, for example, the
server is still running but a peripheral device (e.g. memory subsystem) fails
during a power outage.
Содержание PRIMERGY RX2540 M4
Страница 40: ...40 Upgrade and Maintenance Manual RX2540 M4 Before you start ...
Страница 90: ...90 Upgrade and Maintenance Manual RX2540 M4 Basic hardware procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual RX2540 M4 Power supply unit PSU ...
Страница 228: ...228 Upgrade and Maintenance Manual RX2540 M4 Hard disk drives HDD and solid state drives SSD ...
Страница 344: ...344 Upgrade and Maintenance Manual RX2540 M4 Main memory ...
Страница 362: ...362 Upgrade and Maintenance Manual RX2540 M4 Processor CPU ...
Страница 390: ...390 Upgrade and Maintenance Manual RX2540 M4 Liquid cooling LC ...
Страница 498: ...498 Upgrade and Maintenance Manual RX2540 M4 Additional interfaces ...
Страница 572: ...572 Upgrade and Maintenance Manual RX2540 M4 Appendix A ...
Страница 574: ...574 Upgrade and Maintenance Manual RX2540 M4 Appendix B ...
Страница 575: ...FUJITSU Server PRIMERGY RX2540 M4 System Cabling Overview System Cabling Overview English Cable plan for November 2018 ...
Страница 582: ...8 RX2540 M4 Basic Serial RS 232 Cable plan System Board D3384 RS 232 onboard RS 232 rear C6 ...
Страница 634: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...